Natural Lighting of Studio Apartment with East-Oriented Opening

Logic: Jurnal Rancang Bangun dan Teknologi · Vol. 21 No. 1 (2021) · hlm. 23–30

DOI
10.31940/logic.v21i1.2256
ISSN
2580-5649, 1412-114X
Terbit
2021-03-30
Penerbit
Pusat Penelitian dan Pengabdian kepada Masyarakat (P3M) Politeknik Negeri Bali
Bahasa
eng

Abstrak

Less optimized natural lighting would result in apartment residents being dependent on artificial lighting, thus increasing energy consumption. Building opening orientation considerably influences the natural light intensity. This research aimed to analyze the natural lighting pattern on apartment units with east-oriented opening orientation and determine methods to support the existing condition to be optimized. This research applied the descriptive analysis research method assumed from calculation outcome of the software DIALux. Results indicated a proportion of units in The H-Residence Apartment do not meet the requirements specified by SNI 03 6197-2011, predominantly in the kitchen area. The average light intensity in a day in units with east-oriented opening reached its peak at 08.00 – 09.00 a.m. and decreased towards 16.00 p.m. following the sun path. The light intensity in numerous areas exceeded the requirements significantly. Other factors influencing the natural light distribution are layout and interior element. Several ways to optimize the natural light intensity utilization are adding suitable shading device, using dark-colored interior elements, and considering the sun path in designing building openings.

Jaringan kolaborasi para penulis

5 penulis · 6 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Jakarta State Polytechnic
  • State University of Malang
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sujito SujitoState University of Malang2
Rizka RahmaniaJakarta State Polytechnic1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://ojs.pnb.ac.id/index.php/LOGIC/oai, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Natural Lighting of Studio Apartment with East-Oriented Opening</dc:title>
	<dc:creator>Putri, Aisyah Anindya</dc:creator>
	<dc:creator>Nurwidyaningrum, Dyah</dc:creator>
	<dc:creator>Sari, Tri Wulan</dc:creator>
	<dc:description xml:lang="en-US">Less optimized natural lighting would result in apartment residents being dependent on artificial lighting, thus increasing energy consumption.&amp;nbsp; Building opening orientation considerably influences the natural light intensity. This research aimed to analyze the natural lighting pattern on apartment units with east-oriented opening orientation and determine methods to support the existing condition to be optimized. This research applied the descriptive analysis research method assumed from calculation outcome of the software DIALux. Results indicated a proportion of units in The H-Residence Apartment do not meet the requirements specified by SNI 03 6197-2011, predominantly in the kitchen area.&amp;nbsp; The average light intensity in a day in units with east-oriented opening reached its peak at 08.00 – 09.00 a.m. and decreased towards 16.00 p.m. following the sun path. The light intensity in numerous areas exceeded the requirements significantly. Other factors influencing the natural light distribution are layout and interior element.&amp;nbsp; Several ways to optimize the natural light intensity utilization are adding suitable shading device, using dark-colored interior elements, and considering the sun path in designing building openings.</dc:description>
	<dc:publisher xml:lang="en-US">Pusat Penelitian dan Pengabdian kepada Masyarakat (P3M) Politeknik Negeri Bali</dc:publisher>
	<dc:date>2021-03-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://ojs.pnb.ac.id/index.php/LOGIC/article/view/2256</dc:identifier>
	<dc:identifier>10.31940/logic.v21i1.2256</dc:identifier>
	<dc:source xml:lang="en-US">Logic : Jurnal Rancang Bangun dan Teknologi; Vol 21 No 1 (2021): March; 23-30</dc:source>
	<dc:source>2580-5649</dc:source>
	<dc:source>1412-114X</dc:source>
	<dc:source>10.31940/logic.v21i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://ojs.pnb.ac.id/index.php/LOGIC/article/view/2256/1661</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Logic : Jurnal Rancang Bangun dan Teknologi</dc:rights>
</oai_dc:dc>