Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

EFFECT OF ROOM TEMPERATURE ON THE QUALITY OF DNA FROM EARPHONE SWAB BY OBSERVING MITOCHONDRIAL DNA [mtDNA] D-LOOP REGION OF 126 bp (HVS II, nt 34-159) AND 143 bp (HVS I, nt 16268-16410)

Folia Medica Indonesiana · Vol. 53 No. 2 (2017) · hlm. 86–86

DOI
10.20473/fmi.v53i2.6342
ISSN
2355-8393, 2599-056X
Terbit
2017-11-03
Penerbit
Airlangga University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0/

Abstrak

The objects contained in crime scene and its surroundings have significance in the examination of forensic identification. The most commonly used specimens in the examination for identification are blood/blood spots, semen patches, vaginal swabs, buccal swabs and bones, including items often used by the perpetrator/victim the last time. For example, a mobile phone hearing aid (headset/earphone). In the use of earphones attached to the outer ear skin so it is suspected there is a serumen attached to the tool. One factor that can affect the quality of DNA is the prolonged exposure. Until now in Indonesia the effect of long exposure to room temperature on the quality of DNA on the DNA material of earphone swabs through DNA analysis has not been widely known. The type of study was laboratory experimental. Used earphones are exposed at room temperature within 1, 7, 14 and 20 days. The results of this study indicate that the environmental effect, ie the duration of exposure, affects the decrease in DNA content significantly from day 1 to 20. Detection of PCR mtDNA D-Loop HVS I visualization results 143 bp nt: 16268 16410 shows positive detection results (+) Only at day 1 exposure to room temperature [4 sample/66,67%] and day 7 [3 sample/50%]. Visualization of PCR results mtDNA D-Loop HVS II 126bp nt: 34 -159 was performed on day 1 day room exposure [2 sample/33,37%] and day 7 [6 sample/100%]. Conclusion, the duration of exposure to room temperature affect the quality of DNA from earpiece swab material. Decreased levels of earphones DNA swabs showed a significance value (p <0.005) against the effect of long time exposure to room temperature.

Kata kunci

Jaringan kolaborasi para penulis

29 penulis · 53 tautan kepenulisan bersama · 14 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Airlangga
  • National Research and Innovation Agency
  • State University of Jakarta
  • Ministry of Health, Community Development, Gender, Elderly and Children
  • Universitas Gadjah Mada
  • Institut Ilmu Kesehatan Bhakti Wiyata
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Soekry Erfan KusumaAfiliasi tidak diketahui3
Yeti Eka Sispita SariUniversitas Airlangga3
Agung SosiawanUniversitas Airlangga3
Muktiningsih NurjayadiState University of Jakarta2
Vira SaamiaUniversitas Airlangga2
Fery SetiawanUniversitas Airlangga2
Mieke Sylvia MARUniversitas Airlangga2
Nilly SulistyoriniUniversitas Airlangga2
NovitasariAfiliasi tidak diketahui1
Jenny SunarianiUniversitas Airlangga1
Heni PuspitasariUniversitas Airlangga1
Simon Martin Manyanza NzilibiliMinistry of Health, Community Development, Gender, Elderly and Children1
Novitasari NovitasariNational Research and Innovation Agency1
Abdul Hadi FurqoniNational Research and Innovation Agency1
Wimbuh Tri WidodoUniversitas Airlangga1
Sri Puji Astuti WUniversitas Airlangga1
Indah NurainiUniversitas Gadjah Mada1
Ariyanto WibowoUniversitas Airlangga1
Htet Htet AungAfiliasi tidak diketahui1
Theresia LindawatiAfiliasi tidak diketahui1
Pandu HaninditoAfiliasi tidak diketahui1
Indah Nuraini MasjkurAfiliasi tidak diketahui1
Nabil BahasuanAfiliasi tidak diketahui1
Mely PurnadiantiInstitut Ilmu Kesehatan Bhakti Wiyata1
Andika AliviameitaUniversitas Airlangga1
Biqisthi Ari PutraUniversitas Airlangga1
Imam SusiloUniversitas Airlangga1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210179714, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">EFFECT OF ROOM TEMPERATURE ON THE QUALITY OF DNA FROM EARPHONE SWAB BY OBSERVING MITOCHONDRIAL DNA [mtDNA] D-LOOP REGION OF 126 bp (HVS II, nt 34-159) AND 143 bp (HVS I, nt 16268-16410)</dc:title><dc:creator>Ahmad Yudianto</dc:creator><dc:creator>Nola Margaret</dc:creator><dc:subject>mitochondrial DNA</dc:subject><dc:subject>mtDNA D-loop</dc:subject><dc:subject>DNA degradation</dc:subject><dc:subject>exposure duration</dc:subject><dc:subject>forensic DNA evidence</dc:subject><dc:subject>crime scene evidence</dc:subject><dc:subject>DNA quality</dc:subject><dc:description xml:lang="en">The objects contained in crime scene and its surroundings have significance in the examination of forensic identification. The most commonly used specimens in the examination for identification are blood/blood spots, semen patches, vaginal swabs, buccal swabs and bones, including items often used by the perpetrator/victim the last time. For example, a mobile phone hearing aid (headset/earphone). In the use of earphones attached to the outer ear skin so it is suspected there is a serumen attached to the tool. One factor that can affect the quality of DNA is the prolonged exposure. Until now in Indonesia the effect of long exposure to room temperature on the quality of DNA on the DNA material of earphone swabs through DNA analysis has not been widely known. The type of study was laboratory experimental. Used earphones are exposed at room temperature within 1, 7, 14 and 20 days. The results of this study indicate that the environmental effect, ie the duration of exposure, affects the decrease in DNA content significantly from day 1 to 20. Detection of PCR mtDNA D-Loop HVS I visualization results 143 bp nt: 16268 16410 shows positive detection results (+) Only at day 1 exposure to room temperature [4 sample/66,67%] and day 7 [3 sample/50%]. Visualization of PCR results mtDNA D-Loop HVS II 126bp nt: 34 -159 was performed on day 1 day room exposure [2 sample/33,37%] and day 7 [6 sample/100%]. Conclusion, the duration of exposure to room temperature affect the quality of DNA from earpiece swab material. Decreased levels of earphones DNA swabs showed a significance value (p &lt;0.005) against the effect of long time exposure to room temperature.</dc:description><dc:publisher>Airlangga University</dc:publisher><dc:date>2017-11-03</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.20473/fmi.v53i2.6342</dc:identifier><dc:identifier>10.20473/fmi.v53i2.6342</dc:identifier><dc:source>Folia Medica Indonesiana; Vol 53 No 2 (2017); 86-86</dc:source><dc:source>2355-8393</dc:source><dc:source>2599-056X</dc:source><dc:language>en</dc:language><dc:relation>https://e-journal.unair.ac.id/FMI/article/download/6342/3901</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>