Melola Discovery

← Melola Discovery

Jurnal SINTA 1

MEAN SCORE OF CERVICAL PEDICLE ANGLE TO MIDLINE AND INFERIOR END PLATE IN ADULT USING MULTI SLICED COMPUTED TOMOGRAPHY

Folia Medica Indonesiana · Vol. 50 No. 1 (2014)

ISSN
2355-8393, 2599-056X
Terbit
2014-01-01
Penerbit
Airlangga University
Bahasa
en

Abstrak

Cervical pedicle screw provides multiple benefits to the posterior cervical fixation, that is the strength of load and better control onthe field of coronal, sagittal, and rotational because of the three-column fixation. However, cervical pedicle screw installation cancause neurological and vascular complications. This Descriptive study with a sample of 30 people was aimed to calculate the meanscore of cervical pedicle angle toward the midline and the end plate inferior in normal asymptomatic adults using MSCT atlaboratory Radiology MSCT Graha Amerta Dr. Soetomo Hospital Surabaya in February-June 2010. Among 19 men and 11 women,obtained mean score of cervical pedicle angle to the midline of men is 43.11° to 45.84° on the right side, 43.32° to 45.94° on the leftside, and 43.11° to 45.94° overall. In women, the value is 44.66° to 48.54° on the right side, 45.03° to 48.56° on the left side, and45.03° to 48.56° overall. Mean score of cervical pedicle angle to the end plate inferior on men is 12.47° to 15° on the right side,11.36° to 14.10° on the left side, and 11.3° to 15° overall. While women at 11.48° to 15.03° on the right side, 11.28° to 15.17° on theleft side and 11.28° to 15.17° overall. Cervical pedicle diameter in men ranging from 4.85 mm (SD ± 0.62) to 6.17 mm (SD ± 0.67),in women 4,08 mm (SD ± 0.75) to 5.69 mm (SD ± 0.69). There are differences in cervical pedicle angle to the midline and end plateinferior between men and women. (FMI 2014;50 58-62)

Kata kunci

Jaringan kolaborasi para penulis

10 penulis · 16 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Parahyangan Catholic University
  • Mercu Buana University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Martin WijayaParahyangan Catholic University3
Aswin LimParahyangan Catholic University2
Yohanes Albrecht MontolParahyangan Catholic University1
Ahmad Kemal ArsyadAfiliasi tidak diketahui1
Grisella AgliaParahyangan Catholic University1
Edwin LieParahyangan Catholic University1
Ramli NazirAfiliasi tidak diketahui1
Desiana VidayantiMercu Buana University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210179714, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">MEAN SCORE OF CERVICAL PEDICLE ANGLE TO MIDLINE AND INFERIOR END PLATE IN ADULT USING MULTI SLICED COMPUTED TOMOGRAPHY</dc:title><dc:creator>Ardhiana Kasaba</dc:creator><dc:creator>Paulus Pramono Rahardjo</dc:creator><dc:subject>cervical pedicle screw</dc:subject><dc:subject>pedicle width</dc:subject><dc:subject>pedicle screw placement</dc:subject><dc:subject>sex differences</dc:subject><dc:subject>posterior cervical fixation</dc:subject><dc:subject>normal anatomical values</dc:subject><dc:subject>adults</dc:subject><dc:subject>multidetector computed tomography</dc:subject><dc:subject>pedicle screw complications</dc:subject><dc:subject>pedicle screw malposition</dc:subject><dc:description xml:lang="en">Cervical pedicle screw provides multiple benefits to the posterior cervical fixation, that is the strength of load and better control onthe field of coronal, sagittal, and rotational because of the three-column fixation. However, cervical pedicle screw installation cancause neurological and vascular complications. This Descriptive study with a sample of 30 people was aimed to calculate the meanscore of cervical pedicle angle toward the midline and the end plate inferior in normal asymptomatic adults using MSCT atlaboratory Radiology MSCT Graha Amerta Dr. Soetomo Hospital Surabaya in February-June 2010. Among 19 men and 11 women,obtained mean score of cervical pedicle angle to the midline of men is 43.11° to 45.84° on the right side, 43.32° to 45.94° on the leftside, and 43.11° to 45.94° overall. In women, the value is 44.66° to 48.54° on the right side, 45.03° to 48.56° on the left side, and45.03° to 48.56° overall. Mean score of cervical pedicle angle to the end plate inferior on men is 12.47° to 15° on the right side,11.36° to 14.10° on the left side, and 11.3° to 15° overall. While women at 11.48° to 15.03° on the right side, 11.28° to 15.17° on theleft side and 11.28° to 15.17° overall. Cervical pedicle diameter in men ranging from 4.85 mm (SD ± 0.62) to 6.17 mm (SD ± 0.67),in women 4,08 mm (SD ± 0.75) to 5.69 mm (SD ± 0.69). There are differences in cervical pedicle angle to the midline and end plateinferior between men and women. (FMI 2014;50 58-62)</dc:description><dc:publisher>Airlangga University</dc:publisher><dc:date>2014-01-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>http://journal.unair.ac.id/article_7546_media3_category3.html</dc:identifier><dc:source>Folia Medica Indonesiana; Vol 50 No 1 (2014)</dc:source><dc:source>2355-8393</dc:source><dc:source>2599-056X</dc:source><dc:language>en</dc:language></oai_dc:dc>