BMD-QUS ASSESSMENT RESULT APPROPRIATES TO DIAGNOSE OSTEOPOROSIS

Folia Medica Indonesiana · Vol. 49 No. 2 (2013)

ISSN
2355-8393, 2599-056X
Terbit
2013-04-01
Penerbit
Airlangga University
Bahasa
en

Abstrak

A medical equipment with ultrasound-wave technology, which is called Quantitative Ultrasound (QUS), is readily available tomeasure bone mass/mineral density (BMD) as a tool in diagnosing osteoporosis. This equipment measures the quantity ofultrasound-wave that passes through heel-bone (calcaneus). The measurement results are expressed in T-score and Z-score. Thecharacteristics of QUS are simple, save, and cheap, but the output result is not accurate. WHO’s “gold standard” for BMDmeasurement is Dual-energy X-ray Absorbtiometry (DXA). Up to now, in Indonesia DXA has been available only at Jakarta. Butassessment cost of DXA is relatively expensive for Indonesian people. Moreover, QUS and DXA use Japanese woman bone as thereference. Statistical analysis of 15 parallel assessment results from QUS-DXA is done to get correlation coefficient andmathematical equation between two assessment results. T-scores from QUS are correlated to gr/cm2 and T-scores from DXA of FN(femoral-neck), LS (lumbar-spine) and RD (radius). Z-scores from QUS are correlated to Z-scores from DXA of FN, LS and RD.Statistical analysis is also done to 132 QUS T-score data from woman population with peak bone mass age, in order to getpopulation T-score mean value. QUS assessment results are correlated to DXA assessment results at three sites with meancorrelation coefficient of 0.67. The mean of correlation coefficient got from DXA assessment results at three measurement sites is0.81. Moreover, QUS assessment result is combined and adjusted into this correlation equation, to get DXA data estimation. Themean value of T-score resulted by the reference data analysis is –1 (minus one). This value is then used as a correction factor of theprevious/original QUS reference equation, so that we can have local reference equation and local criterion. QUS-DXA correlationequation is an answer for the rare and expensive DXA assessment. Furthermore, local reference equation and local criterion areseveral ways to increase QUS accuracy as the bone mass/mineral density measurement tool. Hopefully, this research will increasethe optimality of QUS assessment result during the process of diagnosing. Next, the accuracy of diagnosis will increase theeffectiveness & efficiency of therapy, and finally it will raise the quality of public health service. (FMI 2013;49 112-115)

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 9 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Bandung Institute of Technology
  • Telkom University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Untari Novia WisestyTelkom University2
Ayu PurwariantiBandung Institute of Technology1
Adi PancoroBandung Institute of Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210179714, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">BMD-QUS ASSESSMENT RESULT APPROPRIATES TO DIAGNOSE OSTEOPOROSIS</dc:title><dc:creator>Priyambada Cahya Nugraha</dc:creator><dc:creator>Rachmat Gunadi Wachjudi</dc:creator><dc:creator>Tati Rajab Mengko</dc:creator><dc:subject>osteoporosis diagnosis</dc:subject><dc:subject>quantitative ultrasound</dc:subject><dc:subject>bone mineral density</dc:subject><dc:subject>dual-energy X-ray absorptiometry</dc:subject><dc:subject>T-score</dc:subject><dc:subject>Z-score</dc:subject><dc:subject>reference population</dc:subject><dc:subject>women</dc:subject><dc:subject>peak bone mass</dc:subject><dc:subject>Indonesia</dc:subject><dc:subject>WHO criteria</dc:subject><dc:subject>femoral neck</dc:subject><dc:subject>lumbar spine</dc:subject><dc:subject>radius</dc:subject><dc:subject>diagnostic accuracy</dc:subject><dc:subject>public health service quality</dc:subject><dc:description xml:lang="en">A medical equipment with ultrasound-wave technology, which is called Quantitative Ultrasound (QUS), is readily available tomeasure bone mass/mineral density (BMD) as a tool in diagnosing osteoporosis. This equipment measures the quantity ofultrasound-wave that passes through heel-bone (calcaneus). The measurement results are expressed in T-score and Z-score. Thecharacteristics of QUS are simple, save, and cheap, but the output result is not accurate. WHO’s “gold standard” for BMDmeasurement is Dual-energy X-ray Absorbtiometry (DXA). Up to now, in Indonesia DXA has been available only at Jakarta. Butassessment cost of DXA is relatively expensive for Indonesian people. Moreover, QUS and DXA use Japanese woman bone as thereference. Statistical analysis of 15 parallel assessment results from QUS-DXA is done to get correlation coefficient andmathematical equation between two assessment results. T-scores from QUS are correlated to gr/cm2 and T-scores from DXA of FN(femoral-neck), LS (lumbar-spine) and RD (radius). Z-scores from QUS are correlated to Z-scores from DXA of FN, LS and RD.Statistical analysis is also done to 132 QUS T-score data from woman population with peak bone mass age, in order to getpopulation T-score mean value. QUS assessment results are correlated to DXA assessment results at three sites with meancorrelation coefficient of 0.67. The mean of correlation coefficient got from DXA assessment results at three measurement sites is0.81. Moreover, QUS assessment result is combined and adjusted into this correlation equation, to get DXA data estimation. Themean value of T-score resulted by the reference data analysis is –1 (minus one). This value is then used as a correction factor of theprevious/original QUS reference equation, so that we can have local reference equation and local criterion. QUS-DXA correlationequation is an answer for the rare and expensive DXA assessment. Furthermore, local reference equation and local criterion areseveral ways to increase QUS accuracy as the bone mass/mineral density measurement tool. Hopefully, this research will increasethe optimality of QUS assessment result during the process of diagnosing. Next, the accuracy of diagnosis will increase theeffectiveness &amp; efficiency of therapy, and finally it will raise the quality of public health service. (FMI 2013;49 112-115)</dc:description><dc:publisher>Airlangga University</dc:publisher><dc:date>2013-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>http://journal.unair.ac.id/download-fullpapers-fmi282cda2c1efull.pdf</dc:identifier><dc:source>Folia Medica Indonesiana; Vol 49 No 2 (2013)</dc:source><dc:source>2355-8393</dc:source><dc:source>2599-056X</dc:source><dc:language>en</dc:language></oai_dc:dc>