Melola Discovery

← Melola Discovery

Jurnal SINTA 1

DYSFUNCTION OF COCHLEAR AND RETROCOCHLEAR WITH TINNITUS IN NORMAL HEARING

Folia Medica Indonesiana · Vol. 49 No. 4 (2013)

ISSN
2355-8393, 2599-056X
Terbit
2013-10-01
Penerbit
Airlangga University
Bahasa
en

Abstrak

Tinnitus is often accompanied by hearing impairment, although in some cases normal hearing (<25 dB), may mislead the presence ofcochlear or retrocochlear dysfunction. Therefore, further evaluation using OAE and BERA are needed. The purpose of this study isto analyze the relation between cochlea and retrocochlear with normal-hearing tinnitus. A cross-sectional study on 14 normalhearingtinnitus subjects was conducted in out patient otolaryngology Dr.Soetomo Hospital Surabaya with a control group of 11normal-hearing subjects without tinnitus. Statistic analysis were used including Fischer exact test, Mann-Whitney, independent t test,McNemar test and association test Kappa and Likelihood Ratio. From the study, TEOAE there was no significant difference inTEOAE results between study group and control group (p=0.230). DPOAE there was a significant difference in DPOAE resultsbetween study group and control group (p=0.046). In DPOAE evaluation using frequency of 1 KHz, p = 0,003, at 4 kHz the p =0,020, at 6 kHz the p = 0,008 this shows significant difference at frequency of 1, 4 and 6 kHz (p<0,05). Study of BERA thereforethere was no significant difference in BERA (p=0.008). Therefore, the result of BERA between the two groups only latency wave Iwere significantly different (p=0.044). Statistically, none of TEOAE, DPOAE and BERA fulfilled coherency.(FMI 2013;49 272-276)

Kata kunci

Jaringan kolaborasi para penulis

9 penulis · 12 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Airlangga
  • Universitas Gadjah Mada
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Artono ArtonoUniversitas Airlangga1
Rosydiah RahmawatiUniversitas Airlangga1
Aditya BrahmonoUniversitas Airlangga1
Bakti SurarsoUniversitas Airlangga1
Supriyadi SupriyadiUniversitas Gadjah Mada1
Erna ErlindaAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210179714, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">DYSFUNCTION OF COCHLEAR AND RETROCOCHLEAR WITH TINNITUS IN NORMAL HEARING</dc:title><dc:creator>Emmy Pramesthi D.S</dc:creator><dc:creator>Nyilo Purnami</dc:creator><dc:creator>Manshur Shidiq Wiyadi</dc:creator><dc:subject>tinnitus</dc:subject><dc:subject>normal hearing</dc:subject><dc:subject>cochlear dysfunction</dc:subject><dc:subject>transient evoked otoacoustic emissions</dc:subject><dc:subject>distortion product otoacoustic emissions</dc:subject><dc:subject>auditory brainstem response</dc:subject><dc:subject>wave I latency</dc:subject><dc:subject>cochlear function assessment</dc:subject><dc:description xml:lang="en">Tinnitus is often accompanied by hearing impairment, although in some cases normal hearing (&lt;25 dB), may mislead the presence ofcochlear or retrocochlear dysfunction. Therefore, further evaluation using OAE and BERA are needed. The purpose of this study isto analyze the relation between cochlea and retrocochlear with normal-hearing tinnitus. A cross-sectional study on 14 normalhearingtinnitus subjects was conducted in out patient otolaryngology Dr.Soetomo Hospital Surabaya with a control group of 11normal-hearing subjects without tinnitus. Statistic analysis were used including Fischer exact test, Mann-Whitney, independent t test,McNemar test and association test Kappa and Likelihood Ratio. From the study, TEOAE there was no significant difference inTEOAE results between study group and control group (p=0.230). DPOAE there was a significant difference in DPOAE resultsbetween study group and control group (p=0.046). In DPOAE evaluation using frequency of 1 KHz, p = 0,003, at 4 kHz the p =0,020, at 6 kHz the p = 0,008 this shows significant difference at frequency of 1, 4 and 6 kHz (p&lt;0,05). Study of BERA thereforethere was no significant difference in BERA (p=0.008). Therefore, the result of BERA between the two groups only latency wave Iwere significantly different (p=0.044). Statistically, none of TEOAE, DPOAE and BERA fulfilled coherency.(FMI 2013;49 272-276)</dc:description><dc:publisher>Airlangga University</dc:publisher><dc:date>2013-10-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>http://journal.unair.ac.id/filerPDF/fmidb164a8b1dfull.pdf</dc:identifier><dc:source>Folia Medica Indonesiana; Vol 49 No 4 (2013)</dc:source><dc:source>2355-8393</dc:source><dc:source>2599-056X</dc:source><dc:language>en</dc:language></oai_dc:dc>