Melola Discovery

← Melola Discovery

Jurnal SINTA 1

DIFFERENTIATION OF CHLOROFORM ETCHING TIME ON ACRYLIC RESIN DENTURE TEETH TO SHEAR BOND STRENGTH WITH RESIN COMPOSITE

Folia Medica Indonesiana · Vol. 49 No. 3 (2013)

ISSN
2355-8393, 2599-056X
Terbit
2013-07-01
Penerbit
Airlangga University
Bahasa
en

Abstrak

Resin composite has become popular in modifying denture element of acrylic resin. Bond strength of the denture element of acrylicresin with the resin composite is weak. Etching materials are needed to strengthen the bond. The aim of this research is to determinethe different of etching time with chloroform to the shear bond strength of resin composite with denture element of acrylic resin. Thesamples were consisted of denture element of acrylic resin (7X7X4 mm) and resin composite cylinders (diameter 5 mm, thicness2mm). Sixty denture element of acrylic resin were etched with chloroform and 15 samples were untreated for control. Resincomposite was applied onto the surface of acrylic resin denture element that had been etched using split mold. The interface betweenthe acrylic resin denture teeth and resin composite were placed on universal testing machine (Autograph, Shimadzu, Japan), with 1mm/min cross-head speed until it was broken. Data were analyzed using one way ANOVA test. There were significant differences ofshear bond strength of acrylic resin denture teeth with resin composite using chloroform etching materials for 5 compared to 30seconds, 5 compared to 60 seconds, 5 to 120 seconds, 30 to 60 seconds, 30 to 120 seconds, 60 to 120 seconds (p<0.05). The dentureelement of acrylic resin which was not etched showing the lowest shear bond strength. The duration of etching with chloroformwhich was 30 second showing the highest shear bond strength with composite resin(FMI 2013;49 173-176)

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 4 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Airlangga
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Dwiyanti Feriana RatwitaUniversitas Airlangga1
Eny InayatiUniversitas Airlangga1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210179714, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">DIFFERENTIATION OF CHLOROFORM ETCHING TIME ON ACRYLIC RESIN DENTURE TEETH TO SHEAR BOND STRENGTH WITH RESIN COMPOSITE</dc:title><dc:creator>Endang Kusdarjanti</dc:creator><dc:creator>Okti Setyowati</dc:creator><dc:subject>etching time</dc:subject><dc:subject>composite resin</dc:subject><dc:subject>shear bond strength</dc:subject><dc:subject>denture modification</dc:subject><dc:description xml:lang="en">Resin composite has become popular in modifying denture element of acrylic resin. Bond strength of the denture element of acrylicresin with the resin composite is weak. Etching materials are needed to strengthen the bond. The aim of this research is to determinethe different of etching time with chloroform to the shear bond strength of resin composite with denture element of acrylic resin. Thesamples were consisted of denture element of acrylic resin (7X7X4 mm) and resin composite cylinders (diameter 5 mm, thicness2mm). Sixty denture element of acrylic resin were etched with chloroform and 15 samples were untreated for control. Resincomposite was applied onto the surface of acrylic resin denture element that had been etched using split mold. The interface betweenthe acrylic resin denture teeth and resin composite were placed on universal testing machine (Autograph, Shimadzu, Japan), with 1mm/min cross-head speed until it was broken. Data were analyzed using one way ANOVA test. There were significant differences ofshear bond strength of acrylic resin denture teeth with resin composite using chloroform etching materials for 5 compared to 30seconds, 5 compared to 60 seconds, 5 to 120 seconds, 30 to 60 seconds, 30 to 120 seconds, 60 to 120 seconds (p&lt;0.05). The dentureelement of acrylic resin which was not etched showing the lowest shear bond strength. The duration of etching with chloroformwhich was 30 second showing the highest shear bond strength with composite resin(FMI 2013;49 173-176)</dc:description><dc:publisher>Airlangga University</dc:publisher><dc:date>2013-07-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>http://journal.unair.ac.id/filerPDF/fmi22eea369ddfull.pdf</dc:identifier><dc:source>Folia Medica Indonesiana; Vol 49 No 3 (2013)</dc:source><dc:source>2355-8393</dc:source><dc:source>2599-056X</dc:source><dc:language>en</dc:language></oai_dc:dc>