AGREEMENT BETWEEN ESTIMATED APOLIPOPROTEIN B -100 CONCENTRATION AND APOLIPOPROTEIN B-100 CONCENTRATION MEASURED BY IMMUNOTURBIDIMETRIC METHOD

Folia Medica Indonesiana · Vol. 50 No. 1 (2014)

ISSN
2355-8393, 2599-056X
Terbit
2014-01-01
Penerbit
Airlangga University
Bahasa
en

Abstrak

Apo B-100 is synthesized in the liver and only one apo B molecule exists in every LDL, IDL and VLDL particle, therefore, the level ofapo B-100 represents the total number of potentially atherogenic lipid. A formula estimating apo B-100 might help clinicians inareas with limited resources to identify patients with risk factors for cardiovascular disease, so proper management can be carriedout. To evaluate an agreement between estimated apolipoprotein B-100 concentration and apolipoprotein B-100 concentrationmeasured by immunoturbidimetric method. This study was an analytical observational cross sectional design. Serum samples werecollected using simple random sampling method and all specimens were measured for LDL-cholesterol, triglyceride andapolipoproten B-100 concentration. Estimated apo B-100 concentrations were counted using a [Apo B-100= -33.12 + 0.675 x LDL+ 11.95x ln (TG)] formula. Twenty nine of 30 samples (96.67%) showed estimated apo B-100 concentrations higher than measuredapo B-100 concentrations. Difference of the mean of estimated and measured apo B-100 concentration was 10.941 mg/dL, and wasstatistically significant (t= 9.134 (p <0.0001)). Concordance correlation coefficient (CCC) between estimated and measuredapolipoprotein B-100 concentration was 0.854 (<0.90= poor agreement). The agreement between estimated apo B-100concentration and apo B-100 concentration measured with immunoturbidimetric method was poor. Factors that might have causedthis result were freeze-thawing of samples prior to apo B-100 measurement using immunoturbidimetry and the use of triglyceride asone of the variables in the formula in estimating apo B-100.(FMI 2014;50 10-14)

Kata kunci

Jaringan kolaborasi para penulis

8 penulis · 12 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Airlangga
  • Hasanuddin University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Yusfik Helmi HidayatUniversitas Airlangga1
Hantoro IshardyantoUniversitas Airlangga1
Arif SantosoHasanuddin University1
Dwimantoro Iman PrilistiyoAfiliasi tidak diketahui1
Widodo Jatim PudjirahardjoAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210179714, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">AGREEMENT BETWEEN ESTIMATED APOLIPOPROTEIN B -100 CONCENTRATION AND APOLIPOPROTEIN B-100 CONCENTRATION MEASURED BY IMMUNOTURBIDIMETRIC METHOD</dc:title><dc:creator>P Hadisiswoyo</dc:creator><dc:creator>Sidarti Soehita</dc:creator><dc:creator>Leonita Anniwati</dc:creator><dc:subject>apolipoprotein B-100</dc:subject><dc:subject>immunoturbidimetric assay</dc:subject><dc:subject>triglycerides</dc:subject><dc:subject>LDL cholesterol</dc:subject><dc:subject>cardiovascular risk</dc:subject><dc:subject>atherogenic lipids</dc:subject><dc:description xml:lang="en">Apo B-100 is synthesized in the liver and only one apo B molecule exists in every LDL, IDL and VLDL particle, therefore, the level ofapo B-100 represents the total number of potentially atherogenic lipid. A formula estimating apo B-100 might help clinicians inareas with limited resources to identify patients with risk factors for cardiovascular disease, so proper management can be carriedout. To evaluate an agreement between estimated apolipoprotein B-100 concentration and apolipoprotein B-100 concentrationmeasured by immunoturbidimetric method. This study was an analytical observational cross sectional design. Serum samples werecollected using simple random sampling method and all specimens were measured for LDL-cholesterol, triglyceride andapolipoproten B-100 concentration. Estimated apo B-100 concentrations were counted using a [Apo B-100= -33.12 + 0.675 x LDL+ 11.95x ln (TG)] formula. Twenty nine of 30 samples (96.67%) showed estimated apo B-100 concentrations higher than measuredapo B-100 concentrations. Difference of the mean of estimated and measured apo B-100 concentration was 10.941 mg/dL, and wasstatistically significant (t= 9.134 (p &lt;0.0001)). Concordance correlation coefficient (CCC) between estimated and measuredapolipoprotein B-100 concentration was 0.854 (&lt;0.90= poor agreement). The agreement between estimated apo B-100concentration and apo B-100 concentration measured with immunoturbidimetric method was poor. Factors that might have causedthis result were freeze-thawing of samples prior to apo B-100 measurement using immunoturbidimetry and the use of triglyceride asone of the variables in the formula in estimating apo B-100.(FMI 2014;50 10-14)</dc:description><dc:publisher>Airlangga University</dc:publisher><dc:date>2014-01-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>http://journal.unair.ac.id/filerPDF/fmid72bfccbeefull.pdf</dc:identifier><dc:source>Folia Medica Indonesiana; Vol 50 No 1 (2014)</dc:source><dc:source>2355-8393</dc:source><dc:source>2599-056X</dc:source><dc:language>en</dc:language></oai_dc:dc>