Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Hemoglobin A1c (HbA1c) Levels from the Examination of Different Blood Proportions in K2EDTA Tubes using an Enzymatic Method

Folia Medica Indonesiana · Vol. 59 No. 3 (2023) · hlm. 262–266

DOI
10.20473/fmi.v59i3.40652
ISSN
2355-8393, 2599-056X
Terbit
2023-09-10
Penerbit
Airlangga University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0/

Abstrak

Highlights: 1. Research on the effect of blood volume proportion in the examination of HbA1c levels using K2EDTA anticoagulantvhas yet to be widely carried out in Indonesia.2. The analysis conducted utilizing K2EDTA tubes revealed that the varying proportions of blood samples had no effectvon HbA1c levels.3. This article highlights the necessity of evaluating the pre-analytical phase (sample preparation) of a laboratory process to improve the accuracy of the results and minimize false high or low results in the HbA1c test. Abstract Hemoglobin A1c (HbA1c) examination is the gold standard for diagnosing and monitoring diabetes mellitus patients. In the examination, the pre-analytical phase has the most considerable error rate at 61%. One of the contributing factors is the use of anticoagulants that do not adhere to established guidelines. Additionally, the incompatibility of the sample volume proportions and the anticoagulants in K2EDTA tubes has been observed in numerous cases. The significance of HbA1c testing, particularly in the prevention of diabetes complications, underscores the need for appropriate procedures to be followed throughout the sampling and pre-analytical phases. This study aimed to determine the effect of differences in the proportion of blood sample volume and anticoagulants in K2EDTA tubes on HbA1c levels. This research was conducted in August–September 2022. The research samples were collected from the staff and students at the Department of Medical Laboratory Technology, Politeknik Kesehatan Kemenkes Surabaya, Surabaya, Indonesia. The blood samples were divided into K2EDTA tubes with varying volumes of 1 mL, 2 mL, 3 mL, and 4 mL. The HbA1c levels were then examined at the Clinical Chemistry Laboratory of Politeknik Kesehatan Kemenkes Surabaya. The data were analyzed using a one-way ANOVA test. The statistical test results (p>0.05) indicated that the proportion of samples containing anticoagulants in the K2EDTA tubes did not have any significant effect on HbA1c levels. In conclusion, it is acceptable to utilize K2EDTA tubes with varying blood sample volumes for the measurement of HbA1c levels.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 6 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Poltekkes Kemenkes Surabaya
  • Kementerian Kesehatan Republik Indonesia
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Evy Diah WoelansariPoltekkes Kemenkes Surabaya1
Dwi KrihariyaniPoltekkes Kemenkes Surabaya1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210179714, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Hemoglobin A1c (HbA1c) Levels from the Examination of Different Blood Proportions in K2EDTA Tubes using an Enzymatic Method</dc:title><dc:creator>Museyaroh Museyaroh</dc:creator><dc:creator>Musholli Himmatun Nabilah</dc:creator><dc:creator>Retno Werdiningsih</dc:creator><dc:subject>HbA1c</dc:subject><dc:subject>blood sample volume</dc:subject><dc:subject>anticoagulants</dc:subject><dc:subject>pre-analytical phase</dc:subject><dc:subject>sample preparation</dc:subject><dc:subject>diabetes mellitus</dc:subject><dc:subject>enzyme activity assay</dc:subject><dc:subject>laboratory quality control</dc:subject><dc:description xml:lang="en">Highlights: 1. Research on the effect of blood volume proportion in the examination of HbA1c levels using K2EDTA anticoagulantvhas yet to be widely carried out in Indonesia.2. The analysis conducted utilizing K2EDTA tubes revealed that the varying proportions of blood samples had no effectvon HbA1c levels.3. This article highlights the necessity of evaluating the pre-analytical phase (sample preparation) of a laboratory process to improve the accuracy of the results and minimize false high or low results in the HbA1c test. Abstract Hemoglobin A1c (HbA1c) examination is the gold standard for diagnosing and monitoring diabetes mellitus patients. In the examination, the pre-analytical phase has the most considerable error rate at 61%. One of the contributing factors is the use of anticoagulants that do not adhere to established guidelines. Additionally, the incompatibility of the sample volume proportions and the anticoagulants in K2EDTA tubes has been observed in numerous cases. The significance of HbA1c testing, particularly in the prevention of diabetes complications, underscores the need for appropriate procedures to be followed throughout the sampling and pre-analytical phases. This study aimed to determine the effect of differences in the proportion of blood sample volume and anticoagulants in K2EDTA tubes on HbA1c levels. This research was conducted in August–September 2022. The research samples were collected from the staff and students at the Department of Medical Laboratory Technology, Politeknik Kesehatan Kemenkes Surabaya, Surabaya, Indonesia. The blood samples were divided into K2EDTA tubes with varying volumes of 1 mL, 2 mL, 3 mL, and 4 mL. The HbA1c levels were then examined at the Clinical Chemistry Laboratory of Politeknik Kesehatan Kemenkes Surabaya. The data were analyzed using a one-way ANOVA test. The statistical test results (p&gt;0.05) indicated that the proportion of samples containing anticoagulants in the K2EDTA tubes did not have any significant effect on HbA1c levels. In conclusion, it is acceptable to utilize K2EDTA tubes with varying blood sample volumes for the measurement of HbA1c levels.</dc:description><dc:publisher>Airlangga University</dc:publisher><dc:date>2023-09-10</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.20473/fmi.v59i3.40652</dc:identifier><dc:identifier>10.20473/fmi.v59i3.40652</dc:identifier><dc:source>Folia Medica Indonesiana; Vol 59 No 3 (2023); 262-266</dc:source><dc:source>2355-8393</dc:source><dc:source>2599-056X</dc:source><dc:language>en</dc:language><dc:relation>https://e-journal.unair.ac.id/FMI/article/download/40652/27184</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>