Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE

Belitung Nursing Journal · Vol. 3 No. 6 (2017) · hlm. 693–696

DOI
10.33546/bnj.300
ISSN
2477-4073, 2528-181X
Terbit
2017-12-28
Penerbit
Belitung Raya Publisher
Bahasa
en
Lisensi
creativecommons.org/licenses/by/4.0/

Abstrak

Background: Endotracheal suctioning is one of the common supportive measures in intensive care units (ICU), which may be related to complications such as hypoxia. However, a questionable efficacy is still identified to choose suctioning pressure between 130 mmHg and 140 mmHg that is effective for patients with endotracheal tube.Objective: To compare the effectiveness of 130 mmHg and 140 mmHg suctioning pressure on oxygen saturation in patients with endotracheal tube.Methods: This research used a quasi-experimental design with pretest and posttest group. The study was conducted from 31 January to 1 March 2017 in the Hospital of Panti Wilasa Citarum and Hospital of Roemani Muhammadiyah Semarang Indonesia. There were 30 samples recruited using consecutive sampling, with 15 assigned in the 130 mmHg and 140 mmHg suctioning pressure group. Pulse oximetry was used to measure oxygen saturation. Paired t-test and Independent t-test were used for data analysis.Results: Findings showed that there was a statistically significant effect of 130 and 140 mmHg suctioning pressure on oxygen saturation in patients with endotracheal tube with p-value <0.05. There was a significant mean difference of oxygen saturation between 130 mmHg and 140 mmHg suctioning pressure group with p-value 0.004 (<0.05). The mean difference of oxygen saturation between both groups was 13.157.Conclusion: The 140-mmHg suctioning pressure is more effective compared with 130 mmHg suctioning pressure in increasing oxygen saturation in patients with endotracheal tube.

Kata kunci

Jaringan kolaborasi para penulis

27 penulis · 74 tautan kepenulisan bersama · 34 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Politeknik Kesehatan Kemenkes Semarang
  • Kementerian Kesehatan Republik Indonesia
  • University of Brawijaya
  • Universitas Negeri Surabaya
  • Diponegoro University
  • Poltekkes Kemenkes Palu
  • Jenderal Soedirman University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
I.N.G. WardanaUniversity of Brawijaya1
Y YuliantiUniversity of Brawijaya1
Mega NursasongkoUniversity of Brawijaya1
Noor PramonoDiponegoro University1
Melyana Nurul WidyawatiPoliteknik Kesehatan Kemenkes Semarang1
Kadek Yuli HestiPoliteknik Kesehatan Kemenkes Semarang1
Sri WahyuniPoliteknik Kesehatan Kemenkes Semarang1
Imam Djamaluddin MashoediKementerian Kesehatan Republik Indonesia1
Mardiyono MardiyonoJenderal Soedirman University1
Yuli AdmasariPoltekkes Kemenkes Palu1
Titi SuherniPoliteknik Kesehatan Kemenkes Semarang1
Arwani ArwaniPoliteknik Kesehatan Kemenkes Semarang1
Mardiyono MardiyonoKementerian Kesehatan Republik Indonesia1
Novi IndrianiKementerian Kesehatan Republik Indonesia1
Sudirman SudirmanKementerian Kesehatan Republik Indonesia1
Sarkum SarkumKementerian Kesehatan Republik Indonesia1
Syaukia AdiniKementerian Kesehatan Republik Indonesia1
Arip RahmanAfiliasi tidak diketahui1
SudirmanAfiliasi tidak diketahui1
Rr. Sri Endang PujiastutiPoliteknik Kesehatan Kemenkes Semarang1
Soeharyo HadisaputroKementerian Kesehatan Republik Indonesia1
Yuli SulistiyoAfiliasi tidak diketahui1
Shobirun ShobirunAfiliasi tidak diketahui1
Leni LatifahAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210240190, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE</dc:title><dc:creator>Muhaji Muhaji</dc:creator><dc:creator>Bedjo Santoso</dc:creator><dc:creator>Putrono Putrono</dc:creator><dc:subject>endotracheal suctioning</dc:subject><dc:subject>suction pressure</dc:subject><dc:subject>oxygen saturation</dc:subject><dc:subject>endotracheal tube</dc:subject><dc:subject>hypoxia</dc:subject><dc:subject>mechanical ventilation</dc:subject><dc:subject>intensive care unit patients</dc:subject><dc:description xml:lang="en">Background: Endotracheal suctioning is one of the common supportive measures in intensive care units (ICU), which may be related to complications such as hypoxia. However, a questionable efficacy is still identified to choose suctioning pressure between 130 mmHg and 140 mmHg that is effective for patients with endotracheal tube.Objective: To compare the effectiveness of 130 mmHg and 140 mmHg suctioning pressure on oxygen saturation in patients with endotracheal tube.Methods: This research used a quasi-experimental design with pretest and posttest group. The study was conducted from 31 January to 1 March 2017 in the Hospital of Panti Wilasa Citarum and Hospital of Roemani Muhammadiyah Semarang Indonesia. There were 30 samples recruited using consecutive sampling, with 15 assigned in the 130 mmHg and 140 mmHg suctioning pressure group. Pulse oximetry was used to measure oxygen saturation. Paired t-test and Independent t-test were used for data analysis.Results: Findings showed that there was a statistically significant effect of 130 and 140 mmHg suctioning pressure on oxygen saturation in patients with endotracheal tube with p-value &lt;0.05. There was a significant mean difference of oxygen saturation between 130 mmHg and 140 mmHg suctioning pressure group with p-value 0.004 (&lt;0.05). The mean difference of oxygen saturation between both groups was 13.157.Conclusion: The 140-mmHg suctioning pressure is more effective compared with 130 mmHg suctioning pressure in increasing oxygen saturation in patients with endotracheal tube.</dc:description><dc:publisher>Belitung Raya Publisher</dc:publisher><dc:date>2017-12-28</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>http://doi.org/10.33546/bnj.300</dc:identifier><dc:identifier>10.33546/bnj.300</dc:identifier><dc:source>Belitung Nursing Journal; Vol 3 No 6 (2017); 693-696</dc:source><dc:source>2477-4073</dc:source><dc:source>2528-181X</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by/4.0/</dc:rights></oai_dc:dc>