Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

ESTIMASI POLA DISPERSI DEBU, SO2 DAN NOX DARI INDUSTRI SEMEN MENGGUNAKAN MODEL GAUSS YANG DIINTEGRASI DENGAN SCREEN3

Jurnal Pengelolaan Sumberdaya Alam dan Lingkungan (Journal of Natural Resources and Environmental Management) · Vol. 8 No. 1 (2018) · hlm. 109–119

DOI
10.29244/jpsl.8.1.109-119
ISSN
2086-4639, 2460-5824
Terbit
2018-04-01
Penerbit
Bogor Institute of Agriculture
Bahasa
id
Lisensi
creativecommons.org/licenses/by/4.0/

Abstrak

Industrial activities are sources of air pollution.Pollutants dispersion in air influenced by meteorological condition, such as wind speed, wind direction, air temperarture, air turbulence and atmospheric stability.Air quality monitoring is important in controling the worst condition of pollutants concentration.Air quality monitoring is not easy to do, because it is time consuming, costly and need technology, so that air quality model is developed as an alternative air quality monitoring.This research used gaussian model, a model for predicting pollutant concentrations in downwind area.This model is applied in cement industry, focusing on major pollutants of the cement industry.Sources of pollutants consist of dust, SO2 and NOx.The modeling results showed maximum ground level concentration of dust, SO2 and NOx occur at night (7-10 PM).The maximum ground level concentration of dust, SO2 and NOx at night respectively were 13.16 μg / Nm 3, 32.69 μg / Nm 3, 100.21 μg / Nm 3 (N1 stack) and 14.65 μg / Nm 3, 36.65 μg / Nm 3, 128.10 μg / Nm 3 (N2 stack) based from downwind scenarios at night when atmospheric condition was stable.The distance where the maximum ground level concentration occured has a strong correlation with wind speed (-0.82 ≤ r ≤ -1).Based on gaussian model output, air quality monitoring should be executed at night time (stable atmospheric condition) and located at ground level where maximum concentration occured.Increasing 50m of stack can decrease 57% pollutant concentrations in stable condition.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 93 tautan kepenulisan bersama · 22 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • IPB University
  • University of Göttingen
  • Jenderal Soedirman University
  • Badan Pengkajian dan Penerapan Teknologi
  • Sunan Gunung Djati State Islamic University Bandung
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Yonny KoesmaryonoIPB University3
Yadi SetiadiIPB University2
Andes IsmayanaIPB University2
Akhmad FaqihIPB University2
Ummu Ma'rufahIPB University2
Ashehad Ashween AliUniversity of Göttingen2
Alexander KnohlUniversity of Göttingen2
Andreas IbromIPB University1
GRAVENHORsrIPB University1
Didy SopandieIPB University1
Fadliah SalimIPB University1
Iswandi AnasIPB University1
Charlena CharlenaIPB University1
Zainal Alim Mas’udIPB University1
Agung Dhamar SyaktiJenderal Soedirman University1
Christy Nur CahyaniIPB University1
Saiful AnwarIPB University1
Rifki RahmatullahIPB University1
Maulidi FirlandianaAfiliasi tidak diketahui1
Irdika MansurIPB University1
Sari Yulia Kartika HasibuanIPB University1
Dwindrata Basuki AviantaraBadan Pengkajian dan Penerapan Teknologi1
Nastiti Siswi IndrastiIPB University1
Gunawan HadikoAfiliasi tidak diketahui1
Christian StieglerUniversity of Göttingen1
Sasongko HadipandoyoAfiliasi tidak diketahui1
Tatut Hadiwiryono SunarsonoAfiliasi tidak diketahui1
Etty RianiIPB University1
Veybi DjoharamIPB University1
Yudi Agus SetiawanIPB University1
Rachmad HermawanIPB University1
Tsamarah Nada SaninahIPB University1
Syaiful AnwarIPB University1
Nurholis NurholisSunan Gunung Djati State Islamic University Bandung1
NardiIPB University1
M. HendrizalAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210235798, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="id">ESTIMASI POLA DISPERSI DEBU, SO2 DAN NOX DARI INDUSTRI SEMEN MENGGUNAKAN MODEL GAUSS YANG DIINTEGRASI DENGAN SCREEN3</dc:title><dc:creator>Ni Wayan Srimani Puspa Dewi</dc:creator><dc:creator>Tania June</dc:creator><dc:creator>Mohamad Yani</dc:creator><dc:creator>Mujito Mujito</dc:creator><dc:subject>Gaussian dispersion model</dc:subject><dc:subject>air pollution dispersion</dc:subject><dc:subject>cement industry emissions</dc:subject><dc:subject>dust</dc:subject><dc:subject>sulfur dioxide</dc:subject><dc:subject>nitrogen oxides</dc:subject><dc:subject>ground-level concentration</dc:subject><dc:subject>atmospheric stability</dc:subject><dc:subject>wind speed</dc:subject><dc:subject>stack height</dc:subject><dc:subject>air quality monitoring</dc:subject><dc:description xml:lang="id">Industrial activities are sources of air pollution.Pollutants dispersion in air influenced by meteorological condition, such as wind speed, wind direction, air temperarture, air turbulence and atmospheric stability.Air quality monitoring is important in controling the worst condition of pollutants concentration.Air quality monitoring is not easy to do, because it is time consuming, costly and need technology, so that air quality model is developed as an alternative air quality monitoring.This research used gaussian model, a model for predicting pollutant concentrations in downwind area.This model is applied in cement industry, focusing on major pollutants of the cement industry.Sources of pollutants consist of dust, SO2 and NOx.The modeling results showed maximum ground level concentration of dust, SO2 and NOx occur at night (7-10 PM).The maximum ground level concentration of dust, SO2 and NOx at night respectively were 13.16 μg / Nm 3 , 32.69 μg / Nm 3 , 100.21 μg / Nm 3 (N1 stack) and 14.65 μg / Nm 3 , 36.65 μg / Nm 3 , 128.10 μg / Nm 3 (N2 stack) based from downwind scenarios at night when atmospheric condition was stable.The distance where the maximum ground level concentration occured has a strong correlation with wind speed (-0.82 ≤ r ≤ -1).Based on gaussian model output, air quality monitoring should be executed at night time (stable atmospheric condition) and located at ground level where maximum concentration occured.Increasing 50m of stack can decrease 57% pollutant concentrations in stable condition.</dc:description><dc:publisher>Bogor Institute of Agriculture</dc:publisher><dc:date>2018-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>http://doi.org/10.29244/jpsl.8.1.109-119</dc:identifier><dc:identifier>10.29244/jpsl.8.1.109-119</dc:identifier><dc:source>Jurnal Pengelolaan Sumberdaya Alam dan Lingkungan (Journal of Natural Resources and Environmental Management); Vol 8 No 1 (2018); 109-119</dc:source><dc:source>2086-4639</dc:source><dc:source>2460-5824</dc:source><dc:language>id</dc:language><dc:relation>http://journal.ipb.ac.id/index.php/jpsl/article/download/16712/14108</dc:relation><dc:rights>https://creativecommons.org/licenses/by/4.0/</dc:rights></oai_dc:dc>