Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Psychometric evaluation of diagnostic test instruments on physics wave material

Jurnal Penelitian dan Evaluasi Pendidikan · Vol. 29 No. 1 (2025) · hlm. 71–84

DOI
10.21831/pep.v29i1.84655
ISSN
1410-4725, 2338-6061, 2685-7111
Terbit
2025-04-26
Penerbit
State University of Yogyakarta
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

This study aims to evaluate the psychometric quality of diagnostic test instruments on wave material in physics learning, with a focus on their validity and reliability. The instrument was validated by seven experts using the content validation method, which resulted in an average validity score of 0.849, indicating that the instrument is very valid. Confirmatory factor analysis (CFA) was conducted to test the model fit and validity of the instrument structure. The KMO test results showed a figure of 0.946, indicating the suitability of the data for factor analysis, while the Bartlett Test of Sphericity results confirmed that the intercorrelation data was not an identity matrix. The tested model showed a good fit to the data, with a CFI value of 0.948, TLI of 0.935, and RMSEA of 0.072. The model parameter estimates showed a significant relationship between the latent variables and the observed items, with a strong influence from the "Wave" variable. Although the Chi-square test results indicated a statistically poor fit of the model, this result could be influenced by the large sample size. Limitations of this study include the limited sample size of seven validators, which may not cover all perspectives. This study suggests that further research involving a larger number of validators and more in-depth analysis should be conducted to strengthen the results obtained. The results of this study are expected to contribute to the development of more effective diagnostic test instruments for physics teaching at the secondary school level.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 4 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Indonesia University of Education
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Muh. Asriadi AMIndonesia University of Education1
Epi PurnamaIndonesia University of Education1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2737318591, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Psychometric evaluation of diagnostic test instruments on physics wave material</dc:title><dc:creator>Muhammad Asriadi</dc:creator><dc:creator>Anna Isabela Sanam</dc:creator><dc:subject>physics learning</dc:subject><dc:subject>waves</dc:subject><dc:subject>assessment validity</dc:subject><dc:subject>instrument reliability</dc:subject><dc:subject>content validation</dc:subject><dc:subject>confirmatory factor analysis</dc:subject><dc:subject>high school physics</dc:subject><dc:subject>physics education assessment</dc:subject><dc:description xml:lang="en">This study aims to evaluate the psychometric quality of diagnostic test instruments on wave material in physics learning, with a focus on their validity and reliability. The instrument was validated by seven experts using the content validation method, which resulted in an average validity score of 0.849, indicating that the instrument is very valid. Confirmatory factor analysis (CFA) was conducted to test the model fit and validity of the instrument structure. The KMO test results showed a figure of 0.946, indicating the suitability of the data for factor analysis, while the Bartlett Test of Sphericity results confirmed that the intercorrelation data was not an identity matrix. The tested model showed a good fit to the data, with a CFI value of 0.948, TLI of 0.935, and RMSEA of 0.072. The model parameter estimates showed a significant relationship between the latent variables and the observed items, with a strong influence from the "Wave" variable. Although the Chi-square test results indicated a statistically poor fit of the model, this result could be influenced by the large sample size. Limitations of this study include the limited sample size of seven validators, which may not cover all perspectives. This study suggests that further research involving a larger number of validators and more in-depth analysis should be conducted to strengthen the results obtained. The results of this study are expected to contribute to the development of more effective diagnostic test instruments for physics teaching at the secondary school level.</dc:description><dc:publisher>State University of Yogyakarta</dc:publisher><dc:date>2025-04-26</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.21831/pep.v29i1.84655</dc:identifier><dc:identifier>10.21831/pep.v29i1.84655</dc:identifier><dc:source>Jurnal Penelitian dan Evaluasi Pendidikan; Vol 29 No 1 (2025); 71-84</dc:source><dc:source>1410-4725</dc:source><dc:source>2338-6061</dc:source><dc:source>2685-7111</dc:source><dc:language>en</dc:language><dc:relation>https://journal.uny.ac.id/index.php/jpep/article/download/84655/23616</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>