Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Effects of Different Finishing Procedures on Surface Roughness of Hybrid CAD/CAM Materials

Journal of Dentistry Indonesia · Vol. 28 No. 3 (2021)

DOI
10.14693/jdi.v28i3.1298
ISSN
1693-9697, 2355-4800
Terbit
2021-12-30
Penerbit
University of Indonesia
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Hybrid ceramics combine the beneficial properties of resin with the advantage of glass ceramics. However, there are limited study about on roughness properties of hybrid materials. Objective: To investigate of the effects of surface finishing methods on roughness of dental restorations made from hybrid CAD/CAM blocks. Methods: A total of 60 samples were produced (n=20) for three main material groups, two different hybrid ceramic (LAVA Ultimate and VITA Enamic) and a conventional glass ceramic (IPS e.max CAD). Each material group was divided into two subgroups (n=10). Ten samples were polished and 10 were glazed according to related manufacturer instructions. Surface roughness was measured with a surface profilometer. Data were statistically analysed using two-way ANOVA (p<0.05). Results: This study revealed that glazed surfaces were exhibited higher surface roughness values than polished surfaces in all materials (p<0.001). Minimum Ra values were belonged to Lava Ultimate polished group (Ra=0,07 μm) and maximum values were belonged to IPS e.max CAD glazed group (Ra=0,38 μm). Conclusion: Within the limitations of the present study, it may be suggested that finishing the hybrid ceramic restorations by mechanical polishing instead of glaze gives better clinical performance in regard to surface roughness.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 6 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Izmir Kâtip Çelebi University
  • İzmir Demokrasi Üniversitesi
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2736430281, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Effects of Different Finishing Procedures on Surface Roughness of Hybrid CAD/CAM Materials</dc:title><dc:creator>Ender Akan</dc:creator><dc:creator>Özlem Çölgeçen</dc:creator><dc:creator>İbrahim Talha Meşe</dc:creator><dc:creator>Bora Bağış</dc:creator><dc:subject>hybrid ceramic</dc:subject><dc:subject>CAD/CAM dental restorations</dc:subject><dc:subject>surface roughness</dc:subject><dc:subject>polishing</dc:subject><dc:subject>glazing</dc:subject><dc:subject>glass-ceramics</dc:subject><dc:subject>Lava Ultimate</dc:subject><dc:subject>Vita Enamic</dc:subject><dc:subject>IPS e.max CAD</dc:subject><dc:subject>Ras</dc:subject><dc:description xml:lang="en">Hybrid ceramics combine the beneficial properties of resin with the advantage of glass ceramics. However, there are limited study about on roughness properties of hybrid materials. Objective: To investigate of the effects of surface finishing methods on roughness of dental restorations made from hybrid CAD/CAM blocks. Methods: A total of 60 samples were produced (n=20) for three main material groups, two different hybrid ceramic (LAVA Ultimate and VITA Enamic) and a conventional glass ceramic (IPS e.max CAD). Each material group was divided into two subgroups (n=10). Ten samples were polished and 10 were glazed according to related manufacturer instructions. Surface roughness was measured with a surface profilometer. Data were statistically analysed using two-way ANOVA (p&lt;0.05). Results: This study revealed that glazed surfaces were exhibited higher surface roughness values than polished surfaces in all materials (p&lt;0.001). Minimum Ra values were belonged to Lava Ultimate polished group (Ra=0,07 μm) and maximum values were belonged to IPS e.max CAD glazed group (Ra=0,38 μm). Conclusion: Within the limitations of the present study, it may be suggested that finishing the hybrid ceramic restorations by mechanical polishing instead of glaze gives better clinical performance in regard to surface roughness.</dc:description><dc:publisher>University of Indonesia</dc:publisher><dc:date>2021-12-30</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.14693/jdi.v28i3.1298</dc:identifier><dc:identifier>10.14693/jdi.v28i3.1298</dc:identifier><dc:source>Journal of Dentistry Indonesia; Vol 28 No 3 (2021)</dc:source><dc:source>1693-9697</dc:source><dc:source>2355-4800</dc:source><dc:language>en</dc:language><dc:relation>https://scholarhub.ui.ac.id/cgi/viewcontent.cgi?article=1298&amp;context=jdi</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>