Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Trimming and pH Effects on Nickel Ion Release from Stainless Trimming and pH Effects on Nickel Ion Release from Stainless Steel Crowns of Primary Teeth Steel Crowns of

Journal of Dentistry Indonesia · Vol. 27 No. 3 (2020)

DOI
10.14693/jdi.v27i3.1135
ISSN
1693-9697, 2355-4800
Terbit
2020-12-31
Penerbit
University of Indonesia
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Objective: Stainless steel crowns (SSCs) are preformed metal crowns used to restore severely decayed primary teeth. The aim of this study is to evaluate the effects of pH changes and SSC margin trimming on nickel release in artificial saliva solution. Methods: A total of 90 SSCs were divided into three groups and placed in 35 ml of artificial saliva of pH 6.8, 5, and 3.5. Another group consisting 30 SSCs with trimmed margins was placed in saliva of pH 6.8. All SSCs were incubated at 37°C. The concentration of released nickel was assessed on days 1, 7, 14, 21, and 28 by atomic absorption spectrophotometry. Results: The highest concentrations of nickel were released on the first day in all groups. Nickel release increased with decreasing pH, and the differences observed were statistically significant on days 1, 7, 14, and 28. SSC trimming caused a significant increase in nickel release on all days except day 21. Conclusion: The concentration of nickel increased in saliva of low pH. The highest levels of nickel were released with SSC margin trimming because of the loss of integrity of the margins.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 10 tautan kepenulisan bersama · 4 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Mazandaran University of Medical Sciences
  • Islamic Azad University of Ayatollah Amoli
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2736430281, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Trimming and pH Effects on Nickel Ion Release from Stainless Trimming and pH Effects on Nickel Ion Release from Stainless Steel Crowns of Primary Teeth Steel Crowns of</dc:title><dc:creator>Milad Arab‐Nozari</dc:creator><dc:creator>Mohammad Shokrzadeh</dc:creator><dc:creator>Nastaran Zamehran</dc:creator><dc:creator>Jamshid Yazdani Charati</dc:creator><dc:creator>Azam V. Nahvi</dc:creator><dc:subject>stainless steel crowns</dc:subject><dc:subject>nickel release</dc:subject><dc:subject>primary teeth</dc:subject><dc:subject>pH effect</dc:subject><dc:subject>artificial saliva</dc:subject><dc:subject>dental biomaterials</dc:subject><dc:subject>marginal adaptation</dc:subject><dc:subject>metal ion leaching</dc:subject><dc:description xml:lang="en">Objective: Stainless steel crowns (SSCs) are preformed metal crowns used to restore severely decayed primary teeth. The aim of this study is to evaluate the effects of pH changes and SSC margin trimming on nickel release in artificial saliva solution. Methods: A total of 90 SSCs were divided into three groups and placed in 35 ml of artificial saliva of pH 6.8, 5, and 3.5. Another group consisting 30 SSCs with trimmed margins was placed in saliva of pH 6.8. All SSCs were incubated at 37°C. The concentration of released nickel was assessed on days 1, 7, 14, 21, and 28 by atomic absorption spectrophotometry. Results: The highest concentrations of nickel were released on the first day in all groups. Nickel release increased with decreasing pH, and the differences observed were statistically significant on days 1, 7, 14, and 28. SSC trimming caused a significant increase in nickel release on all days except day 21. Conclusion: The concentration of nickel increased in saliva of low pH. The highest levels of nickel were released with SSC margin trimming because of the loss of integrity of the margins.</dc:description><dc:publisher>University of Indonesia</dc:publisher><dc:date>2020-12-31</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.14693/jdi.v27i3.1135</dc:identifier><dc:identifier>10.14693/jdi.v27i3.1135</dc:identifier><dc:source>Journal of Dentistry Indonesia; Vol 27 No 3 (2020)</dc:source><dc:source>1693-9697</dc:source><dc:source>2355-4800</dc:source><dc:language>en</dc:language><dc:relation>https://scholarhub.ui.ac.id/cgi/viewcontent.cgi?article=1135&amp;context=jdi</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>