Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Effect of Preflaring on Accuracy of Endodontic Length Determination by Four Electronic Apex Locators

Journal of Dentistry Indonesia · Vol. 29 No. 3 (2022)

DOI
10.14693/jdi.v29i3.1337
ISSN
1693-9697, 2355-4800
Terbit
2022-12-31
Penerbit
University of Indonesia
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Objective: Root canal anatomy significantly impacts the working length determination. This study aimed to investigate the effect of the preflaring technique on the accuracy of four electronic apex locators. Methods: Forty-five single-canal central maxillary teeth were selected. The working length was measured before and after the coronal preparation by four types of electronic apex locators in the range of ±0.5 and ±1 mm matched for the apical constriction. The actual working length was calculated under a microscope. Data were analyzed using ICC and paired t-tests in SPSS16. A p < 0.05 was considered significant. Results: The accuracies of Root ZX, DTE, Denjoy, and Coxo apex locators in the range of ± 0.05 mm were 71.1, 93.3, 84.4, and 75.6% before preflaring, and 82.2, 93.3, 97.8, and 100% after that. The corresponding values in the range of ±1 mm were 86.7, 97.8, 93.3, and 100% before and 97.8, 100, 100, and 100% after preflaring. Significant differences were found between the working lengths measured by the four devices and the actual working lengths before and after preflaring. Conclusion: The preflaring technique could impact the performance of apex locators in determining the working length and may be advocated for better outcomes.

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Golestan University of Medical Sciences
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2736430281, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Effect of Preflaring on Accuracy of Endodontic Length Determination by Four Electronic Apex Locators</dc:title><dc:creator>Arash Izadi</dc:creator><dc:creator>Maliheh Bayandari</dc:creator><dc:creator>Ezatolah Kazeminejad</dc:creator><dc:subject>electronic apex locators</dc:subject><dc:subject>working length determination</dc:subject><dc:subject>apical constriction</dc:subject><dc:subject>Root ZX</dc:subject><dc:description xml:lang="en">Objective: Root canal anatomy significantly impacts the working length determination. This study aimed to investigate the effect of the preflaring technique on the accuracy of four electronic apex locators. Methods: Forty-five single-canal central maxillary teeth were selected. The working length was measured before and after the coronal preparation by four types of electronic apex locators in the range of ±0.5 and ±1 mm matched for the apical constriction. The actual working length was calculated under a microscope. Data were analyzed using ICC and paired t-tests in SPSS16. A p &lt; 0.05 was considered significant. Results: The accuracies of Root ZX, DTE, Denjoy, and Coxo apex locators in the range of ± 0.05 mm were 71.1, 93.3, 84.4, and 75.6% before preflaring, and 82.2, 93.3, 97.8, and 100% after that. The corresponding values in the range of ±1 mm were 86.7, 97.8, 93.3, and 100% before and 97.8, 100, 100, and 100% after preflaring. Significant differences were found between the working lengths measured by the four devices and the actual working lengths before and after preflaring. Conclusion: The preflaring technique could impact the performance of apex locators in determining the working length and may be advocated for better outcomes.</dc:description><dc:publisher>University of Indonesia</dc:publisher><dc:date>2022-12-31</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.14693/jdi.v29i3.1337</dc:identifier><dc:identifier>10.14693/jdi.v29i3.1337</dc:identifier><dc:source>Journal of Dentistry Indonesia; Vol 29 No 3 (2022)</dc:source><dc:source>1693-9697</dc:source><dc:source>2355-4800</dc:source><dc:language>en</dc:language><dc:relation>https://scholarhub.ui.ac.id/cgi/viewcontent.cgi?article=1337&amp;context=jdi</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>