Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Comparative Evaluation of Apical Extrusion Debris and Irrigant During Calcium Hydroxide Removal and Endodontic During Calcium Hydroxide Removal and Endodontic Instrumentation Using Three Types of Instrumentation Systems Instrumentation Using Three Types of Instrumentation Syste

Journal of Dentistry Indonesia · Vol. 27 No. 3 (2020)

DOI
10.14693/jdi.v27i3.1130
ISSN
1693-9697, 2355-4800
Terbit
2020-12-31
Penerbit
University of Indonesia
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Many root canal preparation techniques and instruments produce apically extruded materials to a certain extent depending on the preparation system adopted. The extrusion of debris from the apical foramen during chemomechanical preparation may cause postoperative pain and failure of endodontic treatment. Objective: This study evaluates the differences in the apical extrusion of debris and calcium hydroxide (CH) during endodontic instrumentation by using Reciproc Blue (RB), WaveOne Gold (WOG), and F6 Skytaper (F6). Methods: Six experimental study groups (n = 13) were established. The root canal procedures for all groups were prepared with different methods: Group I: One Shape (OS) instrumentation, CH filling for 21 days, removal of CH using RB; Group II: OS instrumentation, CH filling for 21 days, removal of CH using WOG; Group III: OS, CaOH filling for 21 days, removal of CH using F6; Group IV: root canal instrumentation using RB; Group V: root canal instrumentation using WOG; Group VI: root canal instrumentation using F6. Apically extruded debris was collected into preweighed Eppendorf tubes by using the Myers and Montgomery method. Data were statistically analyzed with one-way ANOVA and Kruskal–Wallis tests. Results: All the tested instruments caused the extrusion of debris and irrigant from the apical foramen. The difference among the six groups was not statistically significant (p > 0.05). Conclusions: The tested instruments caused similar apical extrusions of debris and irrigant during CH removal or instrumentation procedures.

Kata kunci

Jaringan kolaborasi para penulis

13 penulis · 34 tautan kepenulisan bersama · 12 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Ankara Yıldırım Beyazıt University
  • Gazi University
  • Trakya University
  • Ankara University
  • Ankara Medipol Üniversitesi
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Neslihan BulakAfiliasi tidak diketahui3
Private Practice, Ankara, Turkiye, [email protected] Endodontics SpecialistAnkara Yıldırım Beyazıt University2
Mustafa GüngörmüşAnkara Yıldırım Beyazıt University2
Fatih TulumbacıAnkara Yıldırım Beyazıt University2
Private Practice, Ankara, Turkey Endodontics SpecialistTrakya University1
Esra ÖzyurtGazi University1
Suat ÖzcanGazi University1
Selen İnce YusufoğluAnkara Yıldırım Beyazıt University1
Mert OcakAnkara University1
Ferhat GeneciAnkara Yıldırım Beyazıt University1
Burak BilecenoğluAnkara Medipol Üniversitesi1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2736430281, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Comparative Evaluation of Apical Extrusion Debris and Irrigant During Calcium Hydroxide Removal and Endodontic During Calcium Hydroxide Removal and Endodontic Instrumentation Using Three Types of Instrumentation Systems Instrumentation Using Three Types of Instrumentation Syste</dc:title><dc:creator>Selen İnce Yusufoğlu</dc:creator><dc:creator>Esma Sarıçam</dc:creator><dc:subject>apical extrusion</dc:subject><dc:subject>calcium hydroxide removal</dc:subject><dc:subject>root canal instrumentation</dc:subject><dc:subject>Reciproc Blue</dc:subject><dc:subject>WaveOne Gold</dc:subject><dc:subject>OneShape</dc:subject><dc:subject>apical foramen</dc:subject><dc:subject>irrigant extrusion</dc:subject><dc:subject>endodontic treatment failure</dc:subject><dc:subject>postoperative pain</dc:subject><dc:description xml:lang="en">Many root canal preparation techniques and instruments produce apically extruded materials to a certain extent depending on the preparation system adopted. The extrusion of debris from the apical foramen during chemomechanical preparation may cause postoperative pain and failure of endodontic treatment. Objective: This study evaluates the differences in the apical extrusion of debris and calcium hydroxide (CH) during endodontic instrumentation by using Reciproc Blue (RB), WaveOne Gold (WOG), and F6 Skytaper (F6). Methods: Six experimental study groups (n = 13) were established. The root canal procedures for all groups were prepared with different methods: Group I: One Shape (OS) instrumentation, CH filling for 21 days, removal of CH using RB; Group II: OS instrumentation, CH filling for 21 days, removal of CH using WOG; Group III: OS, CaOH filling for 21 days, removal of CH using F6; Group IV: root canal instrumentation using RB; Group V: root canal instrumentation using WOG; Group VI: root canal instrumentation using F6. Apically extruded debris was collected into preweighed Eppendorf tubes by using the Myers and Montgomery method. Data were statistically analyzed with one-way ANOVA and Kruskal–Wallis tests. Results: All the tested instruments caused the extrusion of debris and irrigant from the apical foramen. The difference among the six groups was not statistically significant (p &gt; 0.05). Conclusions: The tested instruments caused similar apical extrusions of debris and irrigant during CH removal or instrumentation procedures.</dc:description><dc:publisher>University of Indonesia</dc:publisher><dc:date>2020-12-31</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.14693/jdi.v27i3.1130</dc:identifier><dc:identifier>10.14693/jdi.v27i3.1130</dc:identifier><dc:source>Journal of Dentistry Indonesia; Vol 27 No 3 (2020)</dc:source><dc:source>1693-9697</dc:source><dc:source>2355-4800</dc:source><dc:language>en</dc:language><dc:relation>https://scholarhub.ui.ac.id/cgi/viewcontent.cgi?article=1130&amp;context=jdi</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>