Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Microhybrid and Flowable Microhybrid Dental Resin Composites Measured in Fracture Toughness

Journal of Dentistry Indonesia · Vol. 16 No. 1 (2009)

DOI
10.14693/jdi.v16i1.15
ISSN
1693-9697, 2355-4800
Terbit
2009-10-07
Penerbit
University of Indonesia
Bahasa
en

Abstrak

Objectives. The aim of this study was to compare the fracture toughness of a microhybrid and a flowable microhyrid resin composites. Methods. Test specimens (30x15x2)mm made of a microhybrid and a flowable microhybrid were prepared in a double torsion mould and were then polymerized for 20 seconds using a light-curing device. Taken out from the mould, the specimens were than soaked in disfilled water (37°C) for 1 hour and then fractured in a double-torsion technique. t-Test was used to test significance difference between the microhybrid and flowable microhybrid resin composites. Result. The use of double-torsion technique resulted in crack initition and crack arrest which revealed Klc of 1.14 MN/m3/2 and 1.045 MN/m3/2 for the microhybrid and the flowable microhybrid resin composites, respectively. Both resin composites were insignificantly different in the fracture toughness values showed by t–Test. Conclusions. The present study suggested that there was no significant difference between the microhybrid and the flowable microhybrid resin composites tested. It appreared that filler fraction might not affect the fracture toughness of the resin composties tested. DOI: 10.14693/jdi.v16i1.15

Kata kunci

Jaringan kolaborasi para penulis

9 penulis · 13 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Indonesia
  • Universitas Syiah Kuala
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Emil BudiantoUniversity of Indonesia1
Niti MatramUniversity of Indonesia1
Andi SoufyanUniversity of Indonesia1
M. ErlindaUniversity of Indonesia1
Yosi Kusuma EriwatiUniversity of Indonesia1
Viona DiansariUniversitas Syiah Kuala1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2736430281, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Microhybrid and Flowable Microhybrid Dental Resin Composites Measured in Fracture Toughness</dc:title><dc:creator>Decky Joesiana Indrani</dc:creator><dc:creator>Andy Soufyan</dc:creator><dc:creator>Chairunnisa R. R. Chairunnisa</dc:creator><dc:subject>fracture toughness</dc:subject><dc:subject>microhybrid composite</dc:subject><dc:subject>double torsion test</dc:subject><dc:subject>crack initiation</dc:subject><dc:subject>crack arrest</dc:subject><dc:subject>filler volume fraction</dc:subject><dc:subject>dental restorative materials</dc:subject><dc:description xml:lang="en">Objectives. The aim of this study was to compare the fracture toughness of a microhybrid and a flowable microhyrid resin composites. Methods. Test specimens (30x15x2)mm made of a microhybrid and a flowable microhybrid were prepared in a double torsion mould and were then polymerized for 20 seconds using a light-curing device. Taken out from the mould, the specimens were than soaked in disfilled water (37°C) for 1 hour and then fractured in a double-torsion technique. t-Test was used to test significance difference between the microhybrid and flowable microhybrid resin composites. Result. The use of double-torsion technique resulted in crack initition and crack arrest which revealed Klc of 1.14 MN/m3/2 and 1.045 MN/m3/2 for the microhybrid and the flowable microhybrid resin composites, respectively. Both resin composites were insignificantly different in the fracture toughness values showed by t–Test. Conclusions. The present study suggested that there was no significant difference between the microhybrid and the flowable microhybrid resin composites tested. It appreared that filler fraction might not affect the fracture toughness of the resin composties tested. DOI: 10.14693/jdi.v16i1.15</dc:description><dc:publisher>University of Indonesia</dc:publisher><dc:date>2009-10-07</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.14693/jdi.v16i1.15</dc:identifier><dc:identifier>10.14693/jdi.v16i1.15</dc:identifier><dc:source>Journal of Dentistry Indonesia; Vol 16 No 1 (2009)</dc:source><dc:source>1693-9697</dc:source><dc:source>2355-4800</dc:source><dc:language>en</dc:language></oai_dc:dc>