Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

SKIN RADIATION IN PANORAMIC

Journal of Dentistry Indonesia · Vol. 13 No. 2 (2008)

DOI
10.14693/jdi.v13i2.309
ISSN
1693-9697, 2355-4800
Terbit
2008-08-30
Penerbit
University of Indonesia
Bahasa
en
Lisensi
creativecommons.org/licenses/by/4.0/

Abstrak

Dental panoramic radiograph in Indonesia has been widely used. Modern diagnostic imaging equipment with minimum radiation is still very limited. One of the conditions in nuclear safety law, UU 10/1997, is an optimization of all radiation sources with DRL through skin dose measurements. In Indonesia, the national DRL has not been established yet, and there were no reports on the study of panoramic skin dose in Indonesia. The aim of this preliminary study was to obtain a panoramic skin dose radiation as reference to establish DRL in Indonesia. Panoramic radiographs of sixteen female and fifteen male patients, aged 4 – 48 years, were taken using the standard conventional method, with TLD chips attached in location groups. The chips were then read with the detector and integrator of BATAN, in high and low temperature condition at the same time. It was revealed that behind the right and left ear were the regions with the highest radiation dose received, followed by the back of the neck, left jaw, right jaw, and chin. The result of this study has shown the importance of DRL in Indonesia since the use of modern diagnostic imaging equipement that limits radiation dose to the minimum level is still very limited.

Kata kunci

Jaringan kolaborasi para penulis

7 penulis · 8 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Indonesia
  • Universitas Sumatera Utara
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Lindawati Soetanto KusdhanyUniversity of Indonesia1
Tribudi W. RahardjoUniversity of Indonesia1
Trella BoelUniversitas Sumatera Utara1
Miesje Karmiati PurwanegaraUniversity of Indonesia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2736430281, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">SKIN RADIATION IN PANORAMIC</dc:title><dc:creator>Herry Irawan</dc:creator><dc:creator>Hanna Bachtiar Iskandar</dc:creator><dc:creator>D. S. Soekojo Soekojo</dc:creator><dc:subject>panoramic radiography</dc:subject><dc:subject>skin dose</dc:subject><dc:subject>radiation dosimetry</dc:subject><dc:subject>thermoluminescent dosimetry</dc:subject><dc:subject>radiation protection</dc:subject><dc:subject>nuclear safety law</dc:subject><dc:subject>diagnostic imaging equipment</dc:subject><dc:description xml:lang="en">Dental panoramic radiograph in Indonesia has been widely used. Modern diagnostic imaging equipment with minimum radiation is still very limited. One of the conditions in nuclear safety law, UU 10/1997, is an optimization of all radiation sources with DRL through skin dose measurements. In Indonesia, the national DRL has not been established yet, and there were no reports on the study of panoramic skin dose in Indonesia. The aim of this preliminary study was to obtain a panoramic skin dose radiation as reference to establish DRL in Indonesia. Panoramic radiographs of sixteen female and fifteen male patients, aged 4 – 48 years, were taken using the standard conventional method, with TLD chips attached in location groups. The chips were then read with the detector and integrator of BATAN, in high and low temperature condition at the same time. It was revealed that behind the right and left ear were the regions with the highest radiation dose received, followed by the back of the neck, left jaw, right jaw, and chin. The result of this study has shown the importance of DRL in Indonesia since the use of modern diagnostic imaging equipement that limits radiation dose to the minimum level is still very limited.</dc:description><dc:publisher>University of Indonesia</dc:publisher><dc:date>2008-08-30</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.14693/jdi.v13i2.309</dc:identifier><dc:identifier>10.14693/jdi.v13i2.309</dc:identifier><dc:source>Journal of Dentistry Indonesia; Vol 13 No 2 (2008)</dc:source><dc:source>1693-9697</dc:source><dc:source>2355-4800</dc:source><dc:language>en</dc:language><dc:relation>http://www.jdentistry.ui.ac.id/index.php/JDI/article/download/309/218</dc:relation><dc:rights>https://creativecommons.org/licenses/by/4.0/</dc:rights></oai_dc:dc>