Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Kekuatan Geser dan Pola Patahan Loop Space Maintainer yang Dibuat dengan Teknik Spot Welding Elektrik

Journal of Dentistry Indonesia · Vol. 12 No. 2 (2008)

DOI
10.14693/jdi.v12i2.864
ISSN
1693-9697, 2355-4800
Terbit
2008-08-30
Penerbit
University of Indonesia
Bahasa
id

Abstrak

The aim of this research was to study the effect of spot variations on shear strength of spot welds in an electric loop space maintainer. Stainless steel wire of 0.8 mm diameter and nickel chromium crwon for lower second molar of temporary teeth were used. A loop 1 cm wide, made of 3.5 cm stainless steel wire, was welded with 3 dots on the crown using an electric spot welder. Each dot for each group took different spot variations from 1 X – 4 X. A loop space maintainer made with the usual materials and techniques as applied at the IKGA FKG UI Clinic was used as a control, with a torch as heat source. Ten specimens each were prepared for shear testing and three spesimens each for metallography. Universal testing machine was used for shear strength testing at a crosshead speed of 0.5 mm/min, and SEM/EDS was used for metallography and fractography. The data were statistically analyzed with one-way ANOVA at p = 0.05, and Tukey post hoc test. The results show that the shear strength of the welded loop space maintainer was higher than that of a soldered loop space maintainer, although the difference was not statistically significant with spot variation 1 X. SEM/EDS analysis suggests that a new alloy forms at the contact area of welded and soldered loop space maintainer. Fractography of the joints suggests that welds are better than soldered joints, with higher ductility and toughness, as can be seen from the dimpled pattern of the welded joint and cleavage patterns in the control joints. In conclusion, the loop space maintainer is better made by welding than by soldering.

Kata kunci

Jaringan kolaborasi para penulis

20 penulis · 33 tautan kepenulisan bersama · 13 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Indonesia
  • Padjadjaran University
  • University of Brawijaya
  • Diponegoro University
  • Universitas Syiah Kuala
  • Indonesian Institute of Sciences
  • Universitas Sumatera Utara
  • Organisasi lain
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Setyowati SetyowatiUniversity of Indonesia2
Mochamad Fahlevi RizalUniversity of Indonesia1
Boy Muchlis BachtiarUniversity of Indonesia1
Endang Winiati BachtiarUniversity of Indonesia1
Kuswantoro Rusca PutraUniversity of Brawijaya1
Rr. Tutik Sri HayatiUniversity of Indonesia1
Raldi Artono KoestoerUniversity of Indonesia1
Anggorowati AnggorowatiDiponegoro University1
Yosi Kusuma EriwatiUniversity of Indonesia1
Muhammad DhiaulfikriUniversity of Indonesia1
Agus HaryonoIndonesian Institute of Sciences1
Sri FitriyaniUniversitas Syiah Kuala1
Suzanna SungkarUniversitas Sumatera Utara1
Sri Hartini SoemartonoUniversity of Indonesia1
Chandra Nila SukmaUniversity of Indonesia1
Marissa EdyanaUniversity of Indonesia1
Yuke Yulianingsih HeriandiUniversitas Trisakti1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2736430281, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="id">Kekuatan Geser dan Pola Patahan Loop Space Maintainer yang Dibuat dengan Teknik Spot Welding Elektrik</dc:title><dc:creator>Elin Karlina</dc:creator><dc:creator>Ellyza Herda</dc:creator><dc:creator>Heriandi Sutadi</dc:creator><dc:subject>shear strength</dc:subject><dc:subject>fracture patterns</dc:subject><dc:subject>stainless steel wire</dc:subject><dc:subject>soldering</dc:subject><dc:subject>temporary teeth</dc:subject><dc:subject>lower second molar</dc:subject><dc:subject>cleavage fracture</dc:subject><dc:description xml:lang="id">The aim of this research was to study the effect of spot variations on shear strength of spot welds in an electric loop space maintainer. Stainless steel wire of 0.8 mm diameter and nickel chromium crwon for lower second molar of temporary teeth were used. A loop 1 cm wide, made of 3.5 cm stainless steel wire, was welded with 3 dots on the crown using an electric spot welder. Each dot for each group took different spot variations from 1 X – 4 X. A loop space maintainer made with the usual materials and techniques as applied at the IKGA FKG UI Clinic was used as a control, with a torch as heat source. Ten specimens each were prepared for shear testing and three spesimens each for metallography. Universal testing machine was used for shear strength testing at a crosshead speed of 0.5 mm/min, and SEM/EDS was used for metallography and fractography. The data were statistically analyzed with one-way ANOVA at p = 0.05, and Tukey post hoc test. The results show that the shear strength of the welded loop space maintainer was higher than that of a soldered loop space maintainer, although the difference was not statistically significant with spot variation 1 X. SEM/EDS analysis suggests that a new alloy forms at the contact area of welded and soldered loop space maintainer. Fractography of the joints suggests that welds are better than soldered joints, with higher ductility and toughness, as can be seen from the dimpled pattern of the welded joint and cleavage patterns in the control joints. In conclusion, the loop space maintainer is better made by welding than by soldering.</dc:description><dc:publisher>University of Indonesia</dc:publisher><dc:date>2008-08-30</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.14693/jdi.v12i2.864</dc:identifier><dc:identifier>10.14693/jdi.v12i2.864</dc:identifier><dc:source>Journal of Dentistry Indonesia; Vol 12 No 2 (2008)</dc:source><dc:source>1693-9697</dc:source><dc:source>2355-4800</dc:source><dc:language>id</dc:language></oai_dc:dc>