Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Evaluation of Apical Transportation During Calcium Hydroxide Paste Removal Using 2 Different Rotary Systems-invitro study

Journal of Dentistry Indonesia · Vol. 25 No. 2 (2018)

DOI
10.14693/jdi.v25i2.1206
ISSN
1693-9697, 2355-4800
Terbit
2018-08-26
Penerbit
University of Indonesia
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Objectives: This study was done to compare and evaluate incidence of apical transportation during calcium hydroxide paste removal using 2 different rotary systems on 40 degree curved simulated root canal blocks. Materials and Methods: 2 groups (n=15 Group 1- iRace Group 2- ProTaper) of simulated root canals were instrumented till working length. Post instrumentation images were taken under stereomicroscope with corresponding final file inserted into the canal to the working length. Calcium hydroxide paste with iodoform was placed till the working length and removed after 7 days using Master Apical File with copious irrigation. Images were taken under stereomicroscope post calcium hydroxide paste removal with corresponding final file inserted till the working length to assess the incidence of apical transportation. Images were printed and the angle was measured using Schneider’s technique by 3 examiners. Stereomicroscopic images were superimposed using Adobe Photoshop 8 software to observe any deviation in the original path. Results: The mean angle change after rotary instrumentation and calcium hydroxide removal were observed in both groups. Superimposed images showed greater root canal deviation in Group 2 than Group1.

Kata kunci

Jaringan kolaborasi para penulis

6 penulis · 9 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Nitte University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Raksha BhatNitte University1
Preethesh ShettyNitte University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2736430281, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Evaluation of Apical Transportation During Calcium Hydroxide Paste Removal Using 2 Different Rotary Systems-invitro study</dc:title><dc:creator>Aditya Shetty</dc:creator><dc:creator>Lakshmi Nidhi Rao</dc:creator><dc:creator>Divya Tahiliani</dc:creator><dc:creator>Mithra Nidarsh Hegde</dc:creator><dc:subject>apical transportation</dc:subject><dc:subject>rotary instrumentation</dc:subject><dc:subject>irace</dc:subject><dc:subject>ProTaper</dc:subject><dc:subject>iodoform</dc:subject><dc:subject>root canal obturation</dc:subject><dc:subject>simulated root canals</dc:subject><dc:description xml:lang="en">Objectives: This study was done to compare and evaluate incidence of apical transportation during calcium hydroxide paste removal using 2 different rotary systems on 40 degree curved simulated root canal blocks. Materials and Methods: 2 groups (n=15 Group 1- iRace Group 2- ProTaper) of simulated root canals were instrumented till working length. Post instrumentation images were taken under stereomicroscope with corresponding final file inserted into the canal to the working length. Calcium hydroxide paste with iodoform was placed till the working length and removed after 7 days using Master Apical File with copious irrigation. Images were taken under stereomicroscope post calcium hydroxide paste removal with corresponding final file inserted till the working length to assess the incidence of apical transportation. Images were printed and the angle was measured using Schneider’s technique by 3 examiners. Stereomicroscopic images were superimposed using Adobe Photoshop 8 software to observe any deviation in the original path. Results: The mean angle change after rotary instrumentation and calcium hydroxide removal were observed in both groups. Superimposed images showed greater root canal deviation in Group 2 than Group1.</dc:description><dc:publisher>University of Indonesia</dc:publisher><dc:date>2018-08-26</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.14693/jdi.v25i2.1206</dc:identifier><dc:identifier>10.14693/jdi.v25i2.1206</dc:identifier><dc:source>Journal of Dentistry Indonesia; Vol 25 No 2 (2018)</dc:source><dc:source>1693-9697</dc:source><dc:source>2355-4800</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>