Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Effect of Taper and Pitch on Nickle-Titanium File with Variable Cross Section to Its Cyclic Fatigue (In Silico Study)

Journal of Dentistry Indonesia · Vol. 31 No. 1 (2024)

DOI
10.14693/jdi.v30i3.1525
ISSN
1693-9697, 2355-4800
Terbit
2024-04-30
Penerbit
University of Indonesia
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The geometric design of an endodontic file includes cross-sectional shape, taper, and pitch. NiTi endodontic files of OneCurve (MicroMega) are made of two variations of cross-sectional shape, that is, double-s shaped and triple helix. Various kinds of modifications were made to increase the resistance of the NiTi endodontic files from fracture. Cyclic fatigue is the most common factor that causes a fracture of the endodontic file. Objective: The purpose of this study was to obtain a NiTi endodontic file design that has the best cyclic resistance value based on its taper size and number of pitch. Methods: This study used OneCurve endodontic file size 25.06, then scanned with MicroCT Scan and modified the geometric design. The number of file modifications was nine. Taper size modifications were 4%, 6%, and 8%; the number of pitch modifications was reduced by three, fixed, and added by three. Cyclic fatigue measurement simulations were carried out using the finite element method three times each. The result data were analyzed using a two-way ANOVA test and then continued with LSD. Results: The results of the statistical test showed that there was an effect of the size of the taper on the cyclic fatigue values. Endodontic files with a size of a taper 4% had the lowest cyclic fatigue value. Conclusion: The conclusion of this research was that the taper size affects the value of cyclic fatigue in continuous endodontic files made of nickel-titanium with variable cross sections. The number of pitch did not show a significant effect on the cyclic value.

Kata kunci

Jaringan kolaborasi para penulis

7 penulis · 11 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Gadjah Mada
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Christina Widya NugrohowatiUniversitas Gadjah Mada2
Siti SunarintyasUniversitas Gadjah Mada1
Ema MulyawatiUniversitas Gadjah Mada1
Nuryono NuryonoUniversitas Gadjah Mada1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2736430281, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Effect of Taper and Pitch on Nickle-Titanium File with Variable Cross Section to Its Cyclic Fatigue (In Silico Study)</dc:title><dc:creator>Yustika Chrysandra</dc:creator><dc:creator>Tunjung Nugraheni</dc:creator><dc:creator>Wignyo Hadriyanto</dc:creator><dc:subject>nickel-titanium endodontic files</dc:subject><dc:subject>cyclic fatigue</dc:subject><dc:subject>finite element analysis</dc:subject><dc:subject>in silico modeling</dc:subject><dc:description xml:lang="en">The geometric design of an endodontic file includes cross-sectional shape, taper, and pitch. NiTi endodontic files of OneCurve (MicroMega) are made of two variations of cross-sectional shape, that is, double-s shaped and triple helix. Various kinds of modifications were made to increase the resistance of the NiTi endodontic files from fracture. Cyclic fatigue is the most common factor that causes a fracture of the endodontic file. Objective: The purpose of this study was to obtain a NiTi endodontic file design that has the best cyclic resistance value based on its taper size and number of pitch. Methods: This study used OneCurve endodontic file size 25.06, then scanned with MicroCT Scan and modified the geometric design. The number of file modifications was nine. Taper size modifications were 4%, 6%, and 8%; the number of pitch modifications was reduced by three, fixed, and added by three. Cyclic fatigue measurement simulations were carried out using the finite element method three times each. The result data were analyzed using a two-way ANOVA test and then continued with LSD. Results: The results of the statistical test showed that there was an effect of the size of the taper on the cyclic fatigue values. Endodontic files with a size of a taper 4% had the lowest cyclic fatigue value. Conclusion: The conclusion of this research was that the taper size affects the value of cyclic fatigue in continuous endodontic files made of nickel-titanium with variable cross sections. The number of pitch did not show a significant effect on the cyclic value.</dc:description><dc:publisher>University of Indonesia</dc:publisher><dc:date>2024-04-30</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.14693/jdi.v30i3.1525</dc:identifier><dc:identifier>10.14693/jdi.v30i3.1525</dc:identifier><dc:source>Journal of Dentistry Indonesia; Vol 31 No 1 (2024)</dc:source><dc:source>1693-9697</dc:source><dc:source>2355-4800</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>