Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Neutral Zone vs. Conventional Denture Fabrication: A Randomized Crossover Study on Denture Performance

Journal of Dentistry Indonesia (2025)

DOI
10.14693/jdi.v32i2.1865
ISSN
1693-9697, 2355-4800
Terbit
2025-01-01
Penerbit
University of Indonesia
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Objectives: It is challenging to achieve satisfactory outcomes in a complete denture for patients with resorbed residual ridges. Utilization of neutral zone techniques to guide posterior denture tooth arrangement and denture base contouring has been considered for many decades. However, the evidence is still not enough to revise protocols. This study aimed to compare patient satisfaction and stability of neutral zone denture with conventional denture. Methods: A crossover clinical trial was conducted among patients with resorbed mandibular ridges. Each participant received two sets of dentures: one fabricated using the neutral zone technique and one using the conventional method, in a randomized sequence. Denture stability was assessed clinically at the time of insertion. Patient satisfaction was recorded after three weeks of wearing each denture using a structured questionnaire. Data were analyzed using paired t-tests for within-subject comparisons, and carryover effects were evaluated using pre-test. Results: The carry-over effect was not statistically significant for both satisfaction (p = 0.099) and stability (p = 0.316). The stability of neutral zone denture was significantly higher than conventional denture (p = 0.043). Conclusion: Dentures prepared using neutral zone technique have been found to be more stable when compared to ones prepared using conventional methods.

Kata kunci

Jaringan kolaborasi para penulis

7 penulis · 21 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Manipal University College Malaysia
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2736430281, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Neutral Zone vs. Conventional Denture Fabrication: A Randomized Crossover Study on Denture Performance</dc:title><dc:creator>Kannaiyan, Karthik</dc:creator><dc:creator>Chauhan, Arunima</dc:creator><dc:creator>Nayak, Vijayendranath</dc:creator><dc:creator>Devendaran, Riyshmaa</dc:creator><dc:creator>Peterson, Dashmita</dc:creator><dc:creator>Kanesan, Pavittra</dc:creator><dc:creator>Lakshmi, Vityaa</dc:creator><dc:subject>neutral zone technique</dc:subject><dc:subject>complete dentures</dc:subject><dc:subject>denture stability</dc:subject><dc:subject>patient satisfaction</dc:subject><dc:subject>mandibular ridge resorption</dc:subject><dc:subject>conventional denture fabrication</dc:subject><dc:description xml:lang="en">Objectives: It is challenging to achieve satisfactory outcomes in a complete denture for patients with resorbed residual ridges. Utilization of neutral zone techniques to guide posterior denture tooth arrangement and denture base contouring has been considered for many decades. However, the evidence is still not enough to revise protocols. This study aimed to compare patient satisfaction and stability of neutral zone denture with conventional denture. Methods: A crossover clinical trial was conducted among patients with resorbed mandibular ridges. Each participant received two sets of dentures: one fabricated using the neutral zone technique and one using the conventional method, in a randomized sequence. Denture stability was assessed clinically at the time of insertion. Patient satisfaction was recorded after three weeks of wearing each denture using a structured questionnaire. Data were analyzed using paired t-tests for within-subject comparisons, and carryover effects were evaluated using pre-test. Results: The carry-over effect was not statistically significant for both satisfaction (p = 0.099) and stability (p = 0.316). The stability of neutral zone denture was significantly higher than conventional denture (p = 0.043). Conclusion: Dentures prepared using neutral zone technique have been found to be more stable when compared to ones prepared using conventional methods.</dc:description><dc:publisher>University of Indonesia</dc:publisher><dc:date>2025-01-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.14693/jdi.v32i2.1865</dc:identifier><dc:identifier>10.14693/jdi.v32i2.1865</dc:identifier><dc:source>Journal of Dentistry Indonesia; (2025)</dc:source><dc:source>1693-9697</dc:source><dc:source>2355-4800</dc:source><dc:language>en</dc:language><dc:relation>https://scholarhub.ui.ac.id/cgi/viewcontent.cgi?article=1865&amp;context=jdi</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>