Akses terbuka
Jurnal
SINTA 1
Cooling Protocols Impact on Nickel-Titanium Rotary Instruments Cyclic Fatigue Resistance Under Extreme Curvatures and Sodium Hypochlorite
Journal of Dentistry Indonesia (2025)
ISSN 1693-9697, 2355-4800
Terbit 2025-01-01
Penerbit University of Indonesia
Bahasa en
Abstrak
Objective: In this work, Hyflex CM, TruNatomy, and Plex V heat-treated nickel titanium rotary instruments were evaluated at body temperature (36 °C ± 1 °C) with and without a cooling protocol to assess the cyclic fatigue resistance. Methods: A 90° curved stainless-steel block was used for cyclic fatigue tests on 60 randomly selected rotary instruments, divided into two groups of 30: body temperature (n = 10) and body temperature with cooling (n = 10). Instruments were further subdivided into 6 groups of 3 different instruments. Cooling protocol group instruments received 5-second spray cooling every 30 seconds, along with continuous 5% sodium hypochlorite. Instrument fractures were recorded via audiovisual methods, inspected under a stereomicroscope, and statistically analyzed. Results: Significant cyclic fatigue resistance was observed in both body temperature and cooling protocol groups in intergroup and intragroup comparisons. Plex V files outperformed others at body temperature, while TruNatomy showed superior cyclic fatigue resistance in the cooling protocol group. Each group displayed expected signs of cyclic fatigue behavior under the stereomicroscope. Conclusion: All three instruments showed comparable cyclic fatigue resistance at body temperature, and the cooling treatment enhanced their resistance. TruNatomy presents a better outcome than other tested files after the cooling protocol.
Jaringan kolaborasi para penulis
11 penulis ·
30 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2736430281, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Cooling Protocols Impact on Nickel-Titanium Rotary Instruments Cyclic Fatigue Resistance Under Extreme Curvatures and Sodium Hypochlorite</dc:title><dc:creator>Ranparia, Palak Ravjibhai</dc:creator><dc:creator>Joshi, Chintan</dc:creator><dc:creator>Somani, Mona</dc:creator><dc:creator>Patel, Aashray</dc:creator><dc:creator>Desai, Urooj</dc:creator><dc:creator>Prajapati, Janki</dc:creator><dc:subject>nickel-titanium rotary instruments</dc:subject><dc:subject>cyclic fatigue resistance</dc:subject><dc:subject>cooling protocols</dc:subject><dc:subject>spray cooling</dc:subject><dc:subject>sodium hypochlorite</dc:subject><dc:subject>instrument fracture</dc:subject><dc:subject>HyFlex CM</dc:subject><dc:subject>TruNatomy</dc:subject><dc:subject>root canal instrumentation</dc:subject><dc:description xml:lang="en">Objective: In this work, Hyflex CM, TruNatomy, and Plex V heat-treated nickel titanium rotary instruments were evaluated at body temperature (36 °C ± 1 °C) with and without a cooling protocol to assess the cyclic fatigue resistance. Methods: A 90° curved stainless-steel block was used for cyclic fatigue tests on 60 randomly selected rotary instruments, divided into two groups of 30: body temperature (n = 10) and body temperature with cooling (n = 10). Instruments were further subdivided into 6 groups of 3 different instruments. Cooling protocol group instruments received 5-second spray cooling every 30 seconds, along with continuous 5% sodium hypochlorite. Instrument fractures were recorded via audiovisual methods, inspected under a stereomicroscope, and statistically analyzed. Results: Significant cyclic fatigue resistance was observed in both body temperature and cooling protocol groups in intergroup and intragroup comparisons. Plex V files outperformed others at body temperature, while TruNatomy showed superior cyclic fatigue resistance in the cooling protocol group. Each group displayed expected signs of cyclic fatigue behavior under the stereomicroscope. Conclusion: All three instruments showed comparable cyclic fatigue resistance at body temperature, and the cooling treatment enhanced their resistance. TruNatomy presents a better outcome than other tested files after the cooling protocol.</dc:description><dc:publisher>University of Indonesia</dc:publisher><dc:date>2025-01-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.14693/jdi.v32i2.1600</dc:identifier><dc:identifier>10.14693/jdi.v32i2.1600</dc:identifier><dc:source>Journal of Dentistry Indonesia; (2025)</dc:source><dc:source>1693-9697</dc:source><dc:source>2355-4800</dc:source><dc:language>en</dc:language><dc:relation>https://scholarhub.ui.ac.id/cgi/viewcontent.cgi?article=1600&context=jdi</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
0 sitasi
Crossref
Terindeks
lewat DOI
0 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Ranparia, P. R., Joshi, C., Somani, M., Patel, A., Desai, U., & Prajapati, J. (2025). Cooling Protocols Impact on Nickel-Titanium Rotary Instruments Cyclic Fatigue Resistance Under Extreme Curvatures and Sodium Hypochlorite. Journal of Dentistry Indonesia. https://doi.org/10.14693/jdi.v32i2.1600
Salin
IEEE
P. R. Ranparia, C. Joshi, M. Somani, A. Patel, U. Desai, and J. Prajapati, “Cooling Protocols Impact on Nickel-Titanium Rotary Instruments Cyclic Fatigue Resistance Under Extreme Curvatures and Sodium Hypochlorite,” Journal of Dentistry Indonesia, 2025, doi: 10.14693/jdi.v32i2.1600.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.