Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

The Release of Total Metal Ion and Genotoxicity of Stainless Steel Brackets: Experimental Study Using Micronucleus Assay

The Indonesian Biomedical Journal · Vol. 8 No. 2 (2016) · hlm. 97–97

DOI
10.18585/inabj.v8i2.193
ISSN
2085-3297, 2355-9179
Terbit
2016-08-01
Penerbit
Secretariat of The Indonesian Biomedical Journal
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc/4.0/

Abstrak

BACKGROUND: Stainless steel brackets are composed of various metal that may corrode in oral cavity. Corrosion is caused by the release of metal ions such as chromium, nickel, and iron. The release of metal ions can cause adverse effects such as toxicity, allergic, and mutagenicity. To evaluate the biocompatibility of stainless steel brackets, micronucleus assay as one of genotoxicity assay is used in this study. To determine the differences and the correlation of metal ions release and genotoxic activity among three brand stainless steel brackets.METHODS: Three brands of brackets were immersed in artificial saliva for 672 hours and the release of ion chromium, nikel and iron were examined. The cytokynesis block micronucleus assay (CBMN) using lymphocytes was performed as well.RESULTS: The highest metal releasing were nickel, cromium, iron, respectively (30.5, 27.2, 23.4 ppb). There was a significant differences between total nickel and iron ion release among three brand brackets (p=0.04, p=0.02). Genotoxicity of metal ion released was correlated with durration of immersion brackets (p=0.01). Genotoxicity was significant correlated with the release of chromium (p=0.03) and nickel (p=0.01).CONCLUSION: Genotoxicity of stainless steel brackets was influenced by duration of immersion but not influenced by brand brackets. KEYWORDS: genotoxicity, stainless steel brackets, metal ion

Kata kunci

Jaringan kolaborasi para penulis

35 penulis · 113 tautan kepenulisan bersama · 21 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Trisakti
  • University of Indonesia
  • Universitas Airlangga
  • Mahsa University
  • Maranatha Christian University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Indrayadi GunardiUniversitas Trisakti3
Joko KusnotoUniversitas Trisakti3
Sonya Grecila SusiloUniversitas Trisakti2
Ferry SandraUniversitas Trisakti2
Himawan HalimUniversitas Trisakti2
Lydia WinartaUniversitas Trisakti2
Siti Aliyah PradonoUniversity of Indonesia1
Loes D. SjahruddinUniversitas Trisakti1
Melanie Sadono DjamilUniversitas Trisakti1
Diah Savitri ErnawatiUniversitas Airlangga1
Rosnah Binti ZainMahsa University1
Kharissa Kemala VychaktamiUniversitas Trisakti1
Nadia SurjadiUniversitas Trisakti1
Rosalina TjandrawinataUniversitas Trisakti1
Erik HusinUniversitas Trisakti1
Magdalena JulianiUniversitas Trisakti1
Wiwiek PoedjiastoetiUniversitas Trisakti1
Firstine Kelsi HartantoUniversitas Trisakti1
Niko FalatehanUniversitas Trisakti1
Alyah HeriandiUniversitas Trisakti1
Angelita Victoria KurniawanUniversitas Trisakti1
Najla NadiahUniversitas Trisakti1
Andrijanto AndrijantoMaranatha Christian University1
Elizabeth Fitriana SariAfiliasi tidak diketahui1
Janti SudionoUniversitas Trisakti1
Steiven AdhityaUniversitas Trisakti1
Johni HalimUniversitas Trisakti1
Dewi RanggainiUniversitas Trisakti1
Alifah Evi ScaniaUniversity of Indonesia1
Kyung Hoon LeeAfiliasi tidak diketahui1
Elizabeth Yuliani TaramalindaUniversitas Trisakti1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764892910, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">The Release of Total Metal Ion and Genotoxicity of Stainless Steel Brackets: Experimental Study Using Micronucleus Assay</dc:title><dc:creator>Irene Karlina</dc:creator><dc:creator>Rahmi Amtha</dc:creator><dc:creator>Boedi Oetomo Roeslan</dc:creator><dc:creator>Yuniar Zen</dc:creator><dc:subject>metal ion release</dc:subject><dc:subject>genotoxicity</dc:subject><dc:subject>nickel</dc:subject><dc:subject>chromium</dc:subject><dc:subject>iron</dc:subject><dc:subject>immersion time</dc:subject><dc:subject>biocompatibility</dc:subject><dc:subject>micronucleus test</dc:subject><dc:subject>lymphocytes</dc:subject><dc:description xml:lang="en">BACKGROUND: Stainless steel brackets are composed of various metal that may corrode in oral cavity. Corrosion is caused by the release of metal ions such as chromium, nickel, and iron. The release of metal ions can cause adverse effects such as toxicity, allergic, and mutagenicity. To evaluate the biocompatibility of stainless steel brackets, micronucleus assay as one of genotoxicity assay is used in this study. To determine the differences and the correlation of metal ions release and genotoxic activity among three brand stainless steel brackets.METHODS: Three brands of brackets were immersed in artificial saliva for 672 hours and the release of ion chromium, nikel and iron were examined. The cytokynesis block micronucleus assay (CBMN) using lymphocytes was performed as well.RESULTS: The highest metal releasing were nickel, cromium, iron, respectively (30.5, 27.2, 23.4 ppb). There was a significant differences between total nickel and iron ion release among three brand brackets (p=0.04, p=0.02). Genotoxicity of metal ion released was correlated with durration of immersion brackets (p=0.01). Genotoxicity was significant correlated with the release of chromium (p=0.03) and nickel (p=0.01).CONCLUSION: Genotoxicity of stainless steel brackets was influenced by duration of immersion but not influenced by brand brackets. KEYWORDS: genotoxicity, stainless steel brackets, metal ion</dc:description><dc:publisher>Secretariat of The Indonesian Biomedical Journal</dc:publisher><dc:date>2016-08-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.18585/inabj.v8i2.193</dc:identifier><dc:identifier>10.18585/inabj.v8i2.193</dc:identifier><dc:source>The Indonesian Biomedical Journal; Vol 8 No 2 (2016); 97-97</dc:source><dc:source>2085-3297</dc:source><dc:source>2355-9179</dc:source><dc:language>en</dc:language><dc:relation>https://inabj.org/index.php/ibj/article/download/193/310</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc/4.0/</dc:rights></oai_dc:dc>