Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Lung Function Status of Workers Exposed to Welding Fume: A Preliminary Study

The Indonesian Biomedical Journal · Vol. 8 No. 1 (2016) · hlm. 37–37

DOI
10.18585/inabj.v8i1.196
ISSN
2085-3297, 2355-9179
Terbit
2016-04-01
Penerbit
Secretariat of The Indonesian Biomedical Journal
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc/4.0/

Abstrak

BACKGROUND: Exposure to welding fume in the workplace was associated with lung function disorders and occupational asthma. In this study, we determined lung function parameters in men workers exposed to welding fumes from heavy equipment manufacturer. This study is a preliminary study of biomonitoring program in worker exposed to welding fume as our main study. METHODS: A study with case-control design, random study, was conducted among welder (59 subjects) and non-welder (34 subjects) with more than one year experience in the same job task in a heavy equipment manufacturer. All subjects completed physical examination, informed consent, questionnaire and lung function status. Lung function status was measured by spirometer with vital capacity (VC), forced vital capacity (FCV), forced expiratory volume in one second (FEV1) and ratio of FEV1/FVC as test parameters. Linear regression model was developed to identify the risk factor of lung function parameter status using age, working period and smoking status as variables. RESULTS: This study showed that there were significant lower VC, FVC and FEV1 in welder than non-welder, but not difference in ratio of FEV1/FVC. However, there was no significant difference among welder from foundry and fabrication plan. By multivariate analysis, working period was found as a risk factor for lower parameters in lung function among welder. CONCLUSION: Lung function parameters status were significantly lower in welder than non-welder, and working period was the most important indicator for lung function status evaluation among welder. KEYWORDS: vital capacity, VC, forced vital capacity, FCV, forced expiratory volume in one second, FEV1, lung function, ratio of FEV1/FVC, working period

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 129 tautan kepenulisan bersama · 59 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Hasanuddin University
  • Padjadjaran University
  • University of Indonesia
  • PT Prodia StemCell Indonesia (Indonesia)
  • Udayana University
  • Universitas Trisakti
  • Pelita Harapan University
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Anna MeilianaPadjadjaran University87
Nurrani Mustika DewiPadjadjaran University45
Suryani As’ádHasanuddin University13
Yani LinaHasanuddin University6
Gatot Susilo LawrenceHasanuddin University6
Cynthia Retna SartikaPT Prodia StemCell Indonesia (Indonesia)5
Anwar SantosoUdayana University5
Ferry SandraUniversitas Trisakti5
Ilhamjaya PatellongiHasanuddin University4
Syakib BakriHasanuddin University4
Mansyur ArifHasanuddin University4
Teguh RanakusumaUniversity of Indonesia3
Rima HaifaPT Prodia StemCell Indonesia (Indonesia)3
Trilis YuliantiHasanuddin University3
Dewi Sumaryani SoemarkoUniversity of Indonesia3
Andi Asadul IslamHasanuddin University3
Muhammad IlyasUniversity of Indonesia2
Yenny SurjawanHasanuddin University2
Irma Ruslina DefiPadjadjaran University2
Eka Julianta WahjoepramonoPelita Harapan University2
Mansyur AriefHasanuddin University2
Andri HidayatHasanuddin University2
Melisa Intan BarlianaPadjadjaran University2
Keri Lestari DandanPadjadjaran University2
Ahmad FariedPadjadjaran University2
Keri LestariPadjadjaran University2
Marsetio DonosepoetroUniversitas Airlangga2
Burhanuddin BaharHasanuddin University2
Lucia HerminawatiHasanuddin University2
Widjaja LukitoSEAMEO Regional Center for Food and Nutrition2
Indriyanti Rafi SukmawatiHasanuddin University2
Antonia Anna LukitoHasanuddin University2
Dewi MuliatyAfiliasi tidak diketahui2
Teguh Iman SantosoUniversity of Indonesia2
Peter KaboHasanuddin University2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764892910, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Lung Function Status of Workers Exposed to Welding Fume: A Preliminary Study</dc:title><dc:creator>Mulyana Mulyana</dc:creator><dc:creator>Nuri Purwito Adi</dc:creator><dc:creator>Meily L Kurniawidjaja</dc:creator><dc:creator>Andi Wijaya</dc:creator><dc:creator>Irawan Yusuf</dc:creator><dc:subject>welding fume exposure</dc:subject><dc:subject>lung function</dc:subject><dc:subject>welders</dc:subject><dc:subject>occupational exposure</dc:subject><dc:subject>vital capacity</dc:subject><dc:subject>forced vital capacity</dc:subject><dc:subject>FEV1</dc:subject><dc:subject>FEV1/FVC ratio</dc:subject><dc:subject>working hours</dc:subject><dc:subject>risk factors</dc:subject><dc:subject>heavy equipment manufacturing</dc:subject><dc:subject>occupational asthma</dc:subject><dc:description xml:lang="en">BACKGROUND: Exposure to welding fume in the workplace was associated with lung function disorders and occupational asthma. In this study, we determined lung function parameters in men workers exposed to welding fumes from heavy equipment manufacturer. This study is a preliminary study of biomonitoring program in worker exposed to welding fume as our main study. METHODS: A study with case-control design, random study, was conducted among welder (59 subjects) and non-welder (34 subjects) with more than one year experience in the same job task in a heavy equipment manufacturer. All subjects completed physical examination, informed consent, questionnaire and lung function status. Lung function status was measured by spirometer with vital capacity (VC), forced vital capacity (FCV), forced expiratory volume in one second (FEV1) and ratio of FEV1/FVC as test parameters. Linear regression model was developed to identify the risk factor of lung function parameter status using age, working period and smoking status as variables. RESULTS: This study showed that there were significant lower VC, FVC and FEV1 in welder than non-welder, but not difference in ratio of FEV1/FVC. However, there was no significant difference among welder from foundry and fabrication plan. By multivariate analysis, working period was found as a risk factor for lower parameters in lung function among welder. CONCLUSION: Lung function parameters status were significantly lower in welder than non-welder, and working period was the most important indicator for lung function status evaluation among welder. KEYWORDS: vital capacity, VC, forced vital capacity, FCV, forced expiratory volume in one second, FEV1, lung function, ratio of FEV1/FVC, working period</dc:description><dc:publisher>Secretariat of The Indonesian Biomedical Journal</dc:publisher><dc:date>2016-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.18585/inabj.v8i1.196</dc:identifier><dc:identifier>10.18585/inabj.v8i1.196</dc:identifier><dc:source>The Indonesian Biomedical Journal; Vol 8 No 1 (2016); 37-37</dc:source><dc:source>2085-3297</dc:source><dc:source>2355-9179</dc:source><dc:language>en</dc:language><dc:relation>https://inabj.org/index.php/ibj/article/download/196/297</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc/4.0/</dc:rights></oai_dc:dc>