Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Comparison of Syphilis Rapid Diagnostic Test to Rapid Plasma Reagin, Treponema pallidum Haemagglutination Assay and Fluorescent Treponemal Antibody-Absorption for Syphilis and Yaws Diagnostics

The Indonesian Biomedical Journal · Vol. 12 No. 2 (2020) · hlm. 136–142

DOI
10.18585/inabj.v12i2.1029
ISSN
2085-3297, 2355-9179
Terbit
2020-06-29
Penerbit
Secretariat of The Indonesian Biomedical Journal
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc/4.0/

Abstrak

BACKGROUND: Syphilis and yaws are the treponemal infections which have become serious public health problems, and both are serologically indistinguishable. Developed serological tests for syphilis may also be used to diagnose yaws. In remote area, test modality with minimal requirements were needed. This study investigated the diagnostic value of syphilis rapid diagnostic test (RDT) in diagnosing syphilis and yaws.METHODS: For syphilis diagnostic test, serum samples were obtained from patients of outpatient clinic in Dr. Cipto Mangunkusumo National Central General Hospital who were sent for rapid plasma reagin (RPR) and Treponema pallidum haemagglutination assay (TPHA) to clinical laboratory of the hospital. The serum samples were collected and stored at -80°C until the day of testing for syphilis RDT and fluorescent treponemal antibody-absorption (FTA-Abs). For yaws diagnostic test, serum samples were obtained as a part of surveillance study of yaws among children 1-15 years old in West Halmahera. Venous blood samples were used for syphilis RDT and the sera were separated and were sent to Dr. Cipto Mangunkusumo National Central General Hospital for RPR, TPHA, and FTA-Abs tests.RESULTS: For syphilis diagnostic test, among 156 samples, 39 samples were positive with syphilis RDT. The sensitivity of syphilis RDT was similar to RPR and TPHA (100.0%), the specificity was same as TPHA (77.5%), but lower than RPR (84.8%) when compared to FTA-Abs IgM. The sensitivity of syphilis RDT was 62.5% and the specificity was 96.0% when compare to FTA-Abs IgG. For yaws diagnostic test, among 176 samples, 13 samples were positive with syphilis RDT. By using FTA-Abs IgM as gold standard for diagnosing yaws, the RDT have similar sensitivity (50.0%) with RPR and TPHA and syphilis RDT have similar specificity to TPHA (93.1%). If compared to FTA-Abs IgG, the sensitivity of syphilis RDT was 40.0% and the specificity was 98.0%.CONCLUSION: Syphilis RDT gives similar results with TPHA in syphilis and yaws cases. It may be used as a first line screening test latent or untreated syphilis and yaws because of good sensitivity. For yaws diagnosis Syphilis RDT, RPR, and TPHA have low sensitivity, however all those tests have an excellent agreement.KEYWORDS: FTA-Abs, rapid diagnostic test, syphilis, yaws

Kata kunci

Jaringan kolaborasi para penulis

30 penulis · 145 tautan kepenulisan bersama · 100 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Rumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo
  • University of Indonesia
  • Pembuluh Darah Harapan Kita
  • Fatmawati Hospital
  • Eijkman Institute for Molecular Biology
  • Universitas Airlangga
  • Universitas Sumatera Utara
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Nuri Dyah IndrasariRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo4
Alida Roswita HarahapUniversity of Indonesia3
Erlin ListiyaningsihPembuluh Darah Harapan Kita2
Lia Gardenia PartakusumaFatmawati Hospital2
Rianto SetiabudyUniversity of Indonesia2
Idrus AlwiRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo2
Ina Susianti TimanRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo2
Rahajuningsih S DharmaRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo2
Windy SaharPembuluh Darah Harapan Kita2
Renan SukmawanPembuluh Darah Harapan Kita2
Ninik SukartiniRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo2
Dean Handimulya DjumaryoRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo2
Nindy AulianaRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo2
Pande Made S. Dharma PathniUniversity of Indonesia2
Fathoni AfifUniversity of Indonesia2
R. Tedjo SasmonoEijkman Institute for Molecular Biology1
Aryati AryatiUniversitas Airlangga1
Suhendro SuwartoRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo1
Iris RengganisRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo1
Herdiman Theodorus PohanRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo1
Saptawati BardosonoUniversity of Indonesia1
Dewi SukmawatiUniversity of Indonesia1
Bambang SupriyatnoUniversity of Indonesia1
Eka Laksmi HidayatiUniversity of Indonesia1
Sudung Oloan PardedeRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo1
Partini Pudjiastuti TrihonoRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo1
Oke Rina RamayaniUniversitas Sumatera Utara1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764892910, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Comparison of Syphilis Rapid Diagnostic Test to Rapid Plasma Reagin, Treponema pallidum Haemagglutination Assay and Fluorescent Treponemal Antibody-Absorption for Syphilis and Yaws Diagnostics</dc:title><dc:creator>Astuti Giantini</dc:creator><dc:creator>Dewi Wulandari</dc:creator><dc:creator>Siskawati Suparmin</dc:creator><dc:subject>syphilis</dc:subject><dc:subject>yaws</dc:subject><dc:subject>Treponema pallidum</dc:subject><dc:subject>rapid diagnostic tests</dc:subject><dc:subject>TPHA</dc:subject><dc:subject>RPR</dc:subject><dc:subject>serological diagnosis</dc:subject><dc:subject>sensitivity and specificity</dc:subject><dc:subject>IgM and IgG antibodies</dc:subject><dc:subject>West Halmahera</dc:subject><dc:subject>treponemal infection</dc:subject><dc:description xml:lang="en">BACKGROUND: Syphilis and yaws are the treponemal infections which have become serious public health problems, and both are serologically indistinguishable. Developed serological tests for syphilis may also be used to diagnose yaws. In remote area, test modality with minimal requirements were needed. This study investigated the diagnostic value of syphilis rapid diagnostic test (RDT) in diagnosing syphilis and yaws.METHODS: For syphilis diagnostic test, serum samples were obtained from patients of outpatient clinic in Dr. Cipto Mangunkusumo National Central General Hospital who were sent for rapid plasma reagin (RPR) and Treponema pallidum haemagglutination assay (TPHA) to clinical laboratory of the hospital. The serum samples were collected and stored at -80°C until the day of testing for syphilis RDT and fluorescent treponemal antibody-absorption (FTA-Abs). For yaws diagnostic test, serum samples were obtained as a part of surveillance study of yaws among children 1-15 years old in West Halmahera. Venous blood samples were used for syphilis RDT and the sera were separated and were sent to Dr. Cipto Mangunkusumo National Central General Hospital for RPR, TPHA, and FTA-Abs tests.RESULTS: For syphilis diagnostic test, among 156 samples, 39 samples were positive with syphilis RDT. The sensitivity of syphilis RDT was similar to RPR and TPHA (100.0%), the specificity was same as TPHA (77.5%), but lower than RPR (84.8%) when compared to FTA-Abs IgM. The sensitivity of syphilis RDT was 62.5% and the specificity was 96.0% when compare to FTA-Abs IgG. For yaws diagnostic test, among 176 samples, 13 samples were positive with syphilis RDT. By using FTA-Abs IgM as gold standard for diagnosing yaws, the RDT have similar sensitivity (50.0%) with RPR and TPHA and syphilis RDT have similar specificity to TPHA (93.1%). If compared to FTA-Abs IgG, the sensitivity of syphilis RDT was 40.0% and the specificity was 98.0%.CONCLUSION: Syphilis RDT gives similar results with TPHA in syphilis and yaws cases. It may be used as a first line screening test latent or untreated syphilis and yaws because of good sensitivity. For yaws diagnosis Syphilis RDT, RPR, and TPHA have low sensitivity, however all those tests have an excellent agreement.KEYWORDS: FTA-Abs, rapid diagnostic test, syphilis, yaws</dc:description><dc:publisher>Secretariat of The Indonesian Biomedical Journal</dc:publisher><dc:date>2020-06-29</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.18585/inabj.v12i2.1029</dc:identifier><dc:identifier>10.18585/inabj.v12i2.1029</dc:identifier><dc:source>The Indonesian Biomedical Journal; Vol 12 No 2 (2020); 136-142</dc:source><dc:source>2085-3297</dc:source><dc:source>2355-9179</dc:source><dc:language>en</dc:language><dc:relation>https://inabj.org/index.php/ibj/article/download/1029/476</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc/4.0/</dc:rights></oai_dc:dc>