Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Establishment of Reference Value of 20 Amino Acids for Toddlers by High Performance Liquid Chromatography Tandem Mass Spectrometry

The Indonesian Biomedical Journal · Vol. 16 No. 2 (2024) · hlm. 172–179

DOI
10.18585/inabj.v16i2.2902
ISSN
2085-3297, 2355-9179
Terbit
2024-04-30
Penerbit
Secretariat of The Indonesian Biomedical Journal
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc/4.0/

Abstrak

BACKGROUND: Amino acids are one of the essential metabolites, especially the 20 amino acids that are preserved as the building blocks of protein. Alterations in amino acid concentrations are related to disease such as inborn error of metabolism, cancer, as well as nutritional status. Hence, it is necessary to define reference values of 20 plasma-free amino acids for Indonesian toddlers and to establish a robust measurement technique using chromatography with tandem mass spectrometry (MS).METHODS: This study was a cross-sectional preliminary study to establish reference values. The sample was prepared by mixing plasma with 20% sulfosalicylic acid. Plasma-free amino acids were measured with high-performance liquid chromatography (HPLC) non-derivatization technique using column XTerra for chromatographic separation coupled with tandem MS. Amino acids reference values were taken from 101 healthy Indonesian toddlers aged 1-3 years old. Since amino acids data were not Gaussian distributed, the lower and upper of the reference value was established from the 5th percentile and the 95th percentile, respectively.RESULTS: Analysis for 20 amino acids was validated. The accuracy ranged from 90.53-105.39% and the precision ranged from 0.06-3.80%. The limit of detection range was 1-2 nmol/mL, and the limit of quantification range was 2-4 nmol/mL. The result was linear, with R2 higher than 0.998. There was no significant difference between boys and girls for all amino acids except for glycine.CONCLUSION: HPLC with tandem MS method can be used to evaluate amino acids in clinical practice. The reference values obtained are specific for aged 1-3 years old from urban areas in Indonesia. The study suggests that for each population, the reference values for amino acids should be established.KEYWORDS: amino acids, high-performance liquid chromatography, tandem mass spectrometry, reference values, Indonesia

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 154 tautan kepenulisan bersama · 95 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Indonesia
  • Rumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo
  • Pembuluh Darah Harapan Kita
  • Udayana University
  • Universitas Trisakti
  • Eijkman Institute for Molecular Biology
  • Kementerian Kesehatan Republik Indonesia
  • Organisasi lain
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Alida Roswita HarahapUniversity of Indonesia2
Idrus AlwiRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo2
Riza RizaldiUniversity of Indonesia1
Susyana TaminUniversity of Indonesia1
Ratna Dwi RestutiUniversity of Indonesia1
Ronny SuwentoUniversity of Indonesia1
Indra Parmaditya PamungkasUniversity of Indonesia1
Iqbal MochtarUniversity of Indonesia1
Astrid Widajati SulistomoUniversity of Indonesia1
Aria KekalihUniversity of Indonesia1
Noer Triyanto RusliUniversity of Indonesia1
Retno Asti WerdhaniUniversity of Indonesia1
Alvina AlvinaUniversitas Trisakti1
Pusparini PuspariniUniversitas Trisakti1
Joedo PrihartonoUniversity of Indonesia1
Frans Dhyanagiri SuyatnaUniversity of Indonesia1
Dante Saksono HarbuwonoRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo1
Erlin ListiyaningsihPembuluh Darah Harapan Kita1
Lia Gardenia PartakusumaFatmawati Hospital1
Rianto SetiabudyUniversity of Indonesia1
Astuti GiantiniRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo1
Rahajuningsih S DharmaRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo1
Nuri Dyah IndrasariRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo1
Siskawati SuparminUniversity of Indonesia1
Windy SaharPembuluh Darah Harapan Kita1
Renan SukmawanPembuluh Darah Harapan Kita1
Siti Sarah HajarIPB University1
Nurul Ratna Mutu ManikamRumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo1
Mulyana MulyanaHasanuddin University1
Ninik MudjihartiniUniversity of Indonesia1
Ketut SuastikaUdayana University1
Made Ratna SaraswatiUdayana University1
Anak Agung Gde BudhiartaUdayana University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S2764892910, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Establishment of Reference Value of 20 Amino Acids for Toddlers by High Performance Liquid Chromatography Tandem Mass Spectrometry</dc:title><dc:creator>Merci Monica Pasaribu</dc:creator><dc:creator>Suzanna Immanuel</dc:creator><dc:creator>Damayanti Rusli Sjarif</dc:creator><dc:creator>Ina Susianti Timan</dc:creator><dc:creator>Safarina G. Malik</dc:creator><dc:creator>Muchtaruddin Mansyur</dc:creator><dc:creator>Ernawati Simanjuntak</dc:creator><dc:subject>plasma amino acids</dc:subject><dc:subject>reference values</dc:subject><dc:subject>toddlers</dc:subject><dc:subject>HPLC-MS/MS</dc:subject><dc:subject>glycine</dc:subject><dc:subject>sex differences</dc:subject><dc:subject>inborn errors of metabolism</dc:subject><dc:subject>nutritional status</dc:subject><dc:subject>Indonesian children</dc:subject><dc:description xml:lang="en">BACKGROUND: Amino acids are one of the essential metabolites, especially the 20 amino acids that are preserved as the building blocks of protein. Alterations in amino acid concentrations are related to disease such as inborn error of metabolism, cancer, as well as nutritional status. Hence, it is necessary to define reference values of 20 plasma-free amino acids for Indonesian toddlers and to establish a robust measurement technique using chromatography with tandem mass spectrometry (MS).METHODS: This study was a cross-sectional preliminary study to establish reference values. The sample was prepared by mixing plasma with 20% sulfosalicylic acid. Plasma-free amino acids were measured with high-performance liquid chromatography (HPLC) non-derivatization technique using column XTerra for chromatographic separation coupled with tandem MS. Amino acids reference values were taken from 101 healthy Indonesian toddlers aged 1-3 years old. Since amino acids data were not Gaussian distributed, the lower and upper of the reference value was established from the 5th percentile and the 95th percentile, respectively.RESULTS: Analysis for 20 amino acids was validated. The accuracy ranged from 90.53-105.39% and the precision ranged from 0.06-3.80%. The limit of detection range was 1-2 nmol/mL, and the limit of quantification range was 2-4 nmol/mL. The result was linear, with R2 higher than 0.998. There was no significant difference between boys and girls for all amino acids except for glycine.CONCLUSION: HPLC with tandem MS method can be used to evaluate amino acids in clinical practice. The reference values obtained are specific for aged 1-3 years old from urban areas in Indonesia. The study suggests that for each population, the reference values for amino acids should be established.KEYWORDS: amino acids, high-performance liquid chromatography, tandem mass spectrometry, reference values, Indonesia</dc:description><dc:publisher>Secretariat of The Indonesian Biomedical Journal</dc:publisher><dc:date>2024-04-30</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.18585/inabj.v16i2.2902</dc:identifier><dc:identifier>10.18585/inabj.v16i2.2902</dc:identifier><dc:source>The Indonesian Biomedical Journal; Vol 16 No 2 (2024); 172-179</dc:source><dc:source>2085-3297</dc:source><dc:source>2355-9179</dc:source><dc:language>en</dc:language><dc:relation>https://inabj.org/index.php/ibj/article/download/2902/702</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc/4.0/</dc:rights></oai_dc:dc>