Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

The Newton’s Polynomial Based - Automatic Model Generation (AMG) for Sensor Calibration to Improve the Performance of the Low-Cost Ultrasonic Range Finder (HC-SR04)

JURNAL INFOTEL · Vol. 12 No. 3 (2020) · hlm. 115–122

DOI
10.20895/infotel.v12i3.486
ISSN
2085-3688, 2460-0997
Terbit
2020-08-25
Penerbit
LPPM Institut Teknologi Telkom Purwokerto
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The ultrasonic range finder sensors is a general-purpose sensor to measure the distance contactless. This sensor is categorized as a low-cost sensor that is widely used in various applications. This sensor has a significant deviation that leads to significant errors in the measurement result. The error produced by this sensor tends to increase proportionally to the measured distance. The implementation of a particular algorithm is required to reduce the error value. The model-based calibration is a solution to increase accuracy. The model-based solutions are no longer feasible if the states of the model have changed. The length of the usage of the sensor leads to sensor fatigue. Sensor fatigue is one of the causes of model state changes. If the drift is still within the tolerance limit, the sensor performance can still be restored using the calibration method. The model-based calibration calibrates the sensor by using the model. The update of the model must be made whenever the changing of the model state occurred. Since the manual model-making process is not an easy task, time, and cost required, then the Newton polynomial-based (Automatic Model Generation (AMG) has been implemented in this research. The AMG algorithm generates the new sensor model automatically based on the most updated states. This automatic model generation is implemented in the calibration process of the ultrasonic sensor. The implementation of a polynomial-based AMG algorithm for sensor calibration has been succeeded in improving the calibrated sensor’s accuracy by 96.4% and reducing the MSE level from 25.6 to 0.914

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 2 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Dian Nuswantoro
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Dedi NurciptoUniversitas Dian Nuswantoro3

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210188896, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">The Newton’s Polynomial Based - Automatic Model Generation (AMG) for Sensor Calibration to Improve the Performance of the Low-Cost Ultrasonic Range Finder (HC-SR04)</dc:title><dc:creator>Gutama Indra Gandha</dc:creator><dc:creator>Dewi Agustini Santoso</dc:creator><dc:subject>ultrasonic distance sensor</dc:subject><dc:subject>HC-SR04</dc:subject><dc:subject>sensor calibration</dc:subject><dc:subject>Newton polynomial</dc:subject><dc:subject>automatic model generation</dc:subject><dc:subject>low-cost sensors</dc:subject><dc:subject>sensor drift</dc:subject><dc:subject>measurement error reduction</dc:subject><dc:subject>distance measurement accuracy</dc:subject><dc:description xml:lang="en">The ultrasonic range finder sensors is a general-purpose sensor to measure the distance contactless. This sensor is categorized as a low-cost sensor that is widely used in various applications. This sensor has a significant deviation that leads to significant errors in the measurement result. The error produced by this sensor tends to increase proportionally to the measured distance. The implementation of a particular algorithm is required to reduce the error value. The model-based calibration is a solution to increase accuracy. The model-based solutions are no longer feasible if the states of the model have changed. The length of the usage of the sensor leads to sensor fatigue. Sensor fatigue is one of the causes of model state changes. If the drift is still within the tolerance limit, the sensor performance can still be restored using the calibration method. The model-based calibration calibrates the sensor by using the model. The update of the model must be made whenever the changing of the model state occurred. Since the manual model-making process is not an easy task, time, and cost required, then the Newton polynomial-based (Automatic Model Generation (AMG) has been implemented in this research. The AMG algorithm generates the new sensor model automatically based on the most updated states. This automatic model generation is implemented in the calibration process of the ultrasonic sensor. The implementation of a polynomial-based AMG algorithm for sensor calibration has been succeeded in improving the calibrated sensor’s accuracy by 96.4% and reducing the MSE level from 25.6 to 0.914</dc:description><dc:publisher>LPPM Institut Teknologi Telkom Purwokerto</dc:publisher><dc:date>2020-08-25</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.20895/infotel.v12i3.486</dc:identifier><dc:identifier>10.20895/infotel.v12i3.486</dc:identifier><dc:source>JURNAL INFOTEL; Vol 12 No 3 (2020); 115-122</dc:source><dc:source>2085-3688</dc:source><dc:source>2460-0997</dc:source><dc:language>en</dc:language><dc:relation>https://ejournal.st3telkom.ac.id/index.php/infotel/article/download/486/300</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>