The Performance Improvement of the Low-Cost Ultrasonic Range Finder (HC-SR04) Using Newton’s Polynomial Interpolation Algorithm

JURNAL INFOTEL · Vol. 11 No. 4 (2019)

DOI
10.20895/infotel.v11i4.456
ISSN
2085-3688, 2460-0997
Terbit
2019-12-30
Penerbit
LPPM Institut Teknologi Telkom Purwokerto
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The ultrasonic range finder sensors are widely used sensor in many applications such as computer applications, general purpose applications, medical applications, automotive applications and industrial grade applications. The ultrasonic range finder sensor has many advantages. The advantages are easy to use, fast in measuring process, non-contact measurement and suitable for air and underwater environment. However, the ultrasonic range finder has deviation especially for low-cost sensor. It affects the accuracy level of the measurement result that performed by its sensor directly. The HC-SR04 categorized as a low-cost ultrasonic range finder sensor. This sensor has significant error level. The improvement of the accuracy level of this low-cost ultrasonic sensor is expected to this research. The Newton’s polynomial interpolation algorithm has been used in this research to reduce the error during the measurement process. The implementation of Newton’s polynomial interpolation has succeeded to improve the sensor accuracy. The MSE level of 29,96 is obtained without the Newton’s Polynomial Interpolation implementation. The implementation of the Newton’s Polynomial Interpolation algorithm has succeeded to increase the accuracy level of the sensor by 55,54%. It has been proofed by the decrease of MSE level by 13,32.

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 2 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Dian Nuswantoro
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Dewi Agustini SantosoUniversitas Dian Nuswantoro2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210188896, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">The Performance Improvement of the Low-Cost Ultrasonic Range Finder (HC-SR04) Using Newton’s Polynomial Interpolation Algorithm</dc:title><dc:creator>Gutama Indra Gandha</dc:creator><dc:creator>Dedi Nurcipto</dc:creator><dc:subject>HC-SR04 ultrasonic sensor</dc:subject><dc:subject>ultrasonic distance sensor</dc:subject><dc:subject>sensor error correction</dc:subject><dc:subject>measurement accuracy</dc:subject><dc:subject>low-cost sensors</dc:subject><dc:subject>non-contact distance measurement</dc:subject><dc:subject>mean square error reduction</dc:subject><dc:description xml:lang="en">The ultrasonic range finder sensors are widely used sensor in many applications such as computer applications, general purpose applications, medical applications, automotive applications and industrial grade applications. The ultrasonic range finder sensor has many advantages. The advantages are easy to use, fast in measuring process, non-contact measurement and suitable for air and underwater environment. However, the ultrasonic range finder has deviation especially for low-cost sensor. It affects the accuracy level of the measurement result that performed by its sensor directly. The HC-SR04 categorized as a low-cost ultrasonic range finder sensor. This sensor has significant error level. The improvement of the accuracy level of this low-cost ultrasonic sensor is expected to this research. The Newton’s polynomial interpolation algorithm has been used in this research to reduce the error during the measurement process. The implementation of Newton’s polynomial interpolation has succeeded to improve the sensor accuracy. The MSE level of 29,96 is obtained without the Newton’s Polynomial Interpolation implementation. The implementation of the Newton’s Polynomial Interpolation algorithm has succeeded to increase the accuracy level of the sensor by 55,54%. It has been proofed by the decrease of MSE level by 13,32.</dc:description><dc:publisher>LPPM Institut Teknologi Telkom Purwokerto</dc:publisher><dc:date>2019-12-30</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.20895/infotel.v11i4.456</dc:identifier><dc:identifier>10.20895/infotel.v11i4.456</dc:identifier><dc:source>JURNAL INFOTEL; Vol 11 No 4 (2019)</dc:source><dc:source>2085-3688</dc:source><dc:source>2460-0997</dc:source><dc:language>en</dc:language><dc:relation>https://ejournal.st3telkom.ac.id/index.php/infotel/article/download/456/270</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>