Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Resampling Strategies and their Influence on Heart Rate Variability Features in Low Sampling Rate Electrocardiogram Data

JURNAL INFOTEL · Vol. 16 No. 1 (2024)

DOI
10.20895/infotel.v16i1.1049
ISSN
2085-3688, 2460-0997
Terbit
2024-01-25
Penerbit
LPPM Institut Teknologi Telkom Purwokerto
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Heart rate variability (HRV) is a parameter to measure fluctuations in the interval between heartbeats. HRV provides essential insights into the cardiovascular function and autonomic nervous system. Electrocardiograms (ECG) on wearable devices are often recorded at low sampling rates, limiting temporal resolution and information. Resampling is a technique of changing the sampling rate from a high sampling rate to a lower sampling rate and vice versa. This research aims to evaluate the effect of resampling ECG data with a low sampling rate on HRV features. ECG data consists of 50 Hz and 100 Hz sampling rates. Data with a 50 Hz sampling rate is up-sampled up to 100 Hz, while 100 Hz data is down-sampled up to 50 Hz and up-sampled up to 250 Hz using the Fast Fourier Transform Interpolation Method. Upsampling from 50 Hz to 100 Hz shows unsatisfactory results, except for some HRV features such as NN20, pNN20, and CVI. Better results were found when up sampling from 100 Hz up to 250 Hz, with some HRV features showing good concordance values. However, downsampling from 100 Hz up to 50 Hz is unsuitable for HRV feature analysis. To obtain accurate HRV analysis results in all domains, it is highly recommended to use a sampling rate above 100 Hz.

Kata kunci

Jaringan kolaborasi para penulis

13 penulis · 21 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Teknologi Yogyakarta
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Afwan AnggaraUniversitas Teknologi Yogyakarta2
Ilham FathullahUniversitas Teknologi Yogyakarta2
Zamira Putri Helmy AmbarakUniversitas Teknologi Yogyakarta1
Bella TrianaUniversitas Teknologi Yogyakarta1
Vaneza AndiniUniversitas Teknologi Yogyakarta1
Audry Pritha EkaharyaniUniversitas Teknologi Yogyakarta1
Vina Netty WahyuningtyasUniversitas Teknologi Yogyakarta1
Rafly YoganathaUniversitas Teknologi Yogyakarta1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210188896, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Resampling Strategies and their Influence on Heart Rate Variability Features in Low Sampling Rate Electrocardiogram Data</dc:title><dc:creator>Muhammad Zakariyah</dc:creator><dc:creator>Umar Zaky</dc:creator><dc:creator>Muhammad Ichsan Nurjam’an</dc:creator><dc:creator>Agil Ghani Istikmal</dc:creator><dc:creator>Hafizh Athallah Widianto</dc:creator><dc:subject>heart rate variability</dc:subject><dc:subject>electrocardiogram</dc:subject><dc:subject>resampling</dc:subject><dc:subject>low sampling rate</dc:subject><dc:subject>upsampling</dc:subject><dc:subject>downsampling</dc:subject><dc:subject>wearable devices</dc:subject><dc:subject>autonomic nervous system</dc:subject><dc:description xml:lang="en">Heart rate variability (HRV) is a parameter to measure fluctuations in the interval between heartbeats. HRV provides essential insights into the cardiovascular function and autonomic nervous system. Electrocardiograms (ECG) on wearable devices are often recorded at low sampling rates, limiting temporal resolution and information. Resampling is a technique of changing the sampling rate from a high sampling rate to a lower sampling rate and vice versa. This research aims to evaluate the effect of resampling ECG data with a low sampling rate on HRV features. ECG data consists of 50 Hz and 100 Hz sampling rates. Data with a 50 Hz sampling rate is up-sampled up to 100 Hz, while 100 Hz data is down-sampled up to 50 Hz and up-sampled up to 250 Hz using the Fast Fourier Transform Interpolation Method. Upsampling from 50 Hz to 100 Hz shows unsatisfactory results, except for some HRV features such as NN20, pNN20, and CVI. Better results were found when up sampling from 100 Hz up to 250 Hz, with some HRV features showing good concordance values. However, downsampling from 100 Hz up to 50 Hz is unsuitable for HRV feature analysis. To obtain accurate HRV analysis results in all domains, it is highly recommended to use a sampling rate above 100 Hz.</dc:description><dc:publisher>LPPM Institut Teknologi Telkom Purwokerto</dc:publisher><dc:date>2024-01-25</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.20895/infotel.v16i1.1049</dc:identifier><dc:identifier>10.20895/infotel.v16i1.1049</dc:identifier><dc:source>JURNAL INFOTEL; Vol 16 No 1 (2024)</dc:source><dc:source>2085-3688</dc:source><dc:source>2460-0997</dc:source><dc:language>en</dc:language><dc:relation>https://ejournal.ittelkom-pwt.ac.id/index.php/infotel/article/download/1049/479</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>