Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Utilization of PID Controller to Optimize Energy Consumption in Hybrid Forced Convection Dryer

JURNAL INFOTEL · Vol. 16 No. 3 (2024)

DOI
10.20895/infotel.v16i3.1096
ISSN
2085-3688, 2460-0997
Terbit
2024-09-24
Penerbit
LPPM Institut Teknologi Telkom Purwokerto
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The drying process is essential in food processing, particularly for grains or beans. This process can influence the characteristics and quality of the dried material. However, the drying process needs massive energy. This condition can increase the cost of production. Therefore, optimizing energy is needed during the drying process. PID controller was proposed to be utilized in the dryer to maximize energy efficiency in this study. This method was implemented in forced convection and hybrid forced convection dryer. The temperature sensor was used as parameter control of the PID method to control the electric heater and exhaust fan. Moreover, PZEM-004T was used to measure the energy consumption. The objective of this study is to implement and fine-tune the PID controller to obtain the performance difference between two types of dryers, namely forced convection and hybrid forced convection. This will be achieved by collecting data on power and energy consumption. The results indicate that the hybrid dryer can significantly decrease power and energy consumption by 48.32% and 49.18%, respectively, compared to the forced convection dryer.

Kata kunci

Jaringan kolaborasi para penulis

10 penulis · 23 tautan kepenulisan bersama · 17 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Telkom University
  • Universitas Airlangga
  • SRM Institute of Science and Technology
  • Universitas Gadjah Mada
  • Sultan Agung Islamic University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Prisma MegantoroUniversitas Airlangga5
P. VigneshwaranSRM Institute of Science and Technology2
Herlambang SetiadiUniversitas Airlangga1
Mohammad Aldrin ArifinTelkom University1
Porman PangaribuanTelkom University1
Hendra Ari WinarnoUniversitas Gadjah Mada1
Abdufattah YuriantaUniversitas Airlangga1
Abdul LatifSultan Agung Islamic University1
Bandiyah Sri AprilliaTelkom University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210188896, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Utilization of PID Controller to Optimize Energy Consumption in Hybrid Forced Convection Dryer</dc:title><dc:creator>Brahmantya Aji Pramudita</dc:creator><dc:subject>PID controller</dc:subject><dc:subject>energy optimization</dc:subject><dc:subject>food drying</dc:subject><dc:subject>grain drying</dc:subject><dc:subject>exhaust fan control</dc:subject><dc:subject>temperature sensors</dc:subject><dc:subject>energy efficiency</dc:subject><dc:description xml:lang="en">The drying process is essential in food processing, particularly for grains or beans. This process can influence the characteristics and quality of the dried material. However, the drying process needs massive energy. This condition can increase the cost of production. Therefore, optimizing energy is needed during the drying process. PID controller was proposed to be utilized in the dryer to maximize energy efficiency in this study. This method was implemented in forced convection and hybrid forced convection dryer. The temperature sensor was used as parameter control of the PID method to control the electric heater and exhaust fan. Moreover, PZEM-004T was used to measure the energy consumption. The objective of this study is to implement and fine-tune the PID controller to obtain the performance difference between two types of dryers, namely forced convection and hybrid forced convection. This will be achieved by collecting data on power and energy consumption. The results indicate that the hybrid dryer can significantly decrease power and energy consumption by 48.32% and 49.18%, respectively, compared to the forced convection dryer.</dc:description><dc:publisher>LPPM Institut Teknologi Telkom Purwokerto</dc:publisher><dc:date>2024-09-24</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.20895/infotel.v16i3.1096</dc:identifier><dc:identifier>10.20895/infotel.v16i3.1096</dc:identifier><dc:source>JURNAL INFOTEL; Vol 16 No 3 (2024)</dc:source><dc:source>2085-3688</dc:source><dc:source>2460-0997</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>