Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Monitoring of three-phase distribution power transformer based on the Internet of Things (IoT) and SCADA

JURNAL INFOTEL · Vol. 15 No. 2 (2023) · hlm. 89–97

DOI
10.20895/infotel.v15i2.937
ISSN
2085-3688, 2460-0997
Terbit
2023-05-08
Penerbit
LPPM Institut Teknologi Telkom Purwokerto
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The three-phase distribution transfomer, equipment for stepping down the voltage from medium (20/11,5 kV) to low voltage network (400/231 V) with a constant power, is a type of the PT. PLN (Persero) assets which has a direct relationship with customers. The condition and the performance of transformer are affecting on how the continuity of the electricity distributed. Hence, the monitoring process of three-phase distribution transfomer condition and performance should be done. Some elements which have to be monitored such as voltage (ZMPT101B sensor), current (ACS712 30 A sensor), power, and transfomer load. Those elements could be included as an electrical indicator.And then the transfomer’s temperature (DS18B20 sensor) and the oil transfomer level (HC SR04 sensor) could be included as a mechanical indicator. All of the sensors are processed and programmed with Arduino Mega 2560 which has been connected directly into an additional modul called Ethernet shield and router. The results then emitted by WiFi into SCADA to be shown. The results shown by SCADA is the information whether transformer need to be maintened or not

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 7 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Politeknik Negeri Semarang
  • Universitas Muhammadiyah PKU Surakarta
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Aggie Brenda VernandezPoliteknik Negeri Semarang1
Septiantar Tebe NursaputroPoliteknik Negeri Semarang1
Pangestuningtyas Diah LarasatiPoliteknik Negeri Semarang1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210188896, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Monitoring of three-phase distribution power transformer based on the Internet of Things (IoT) and SCADA</dc:title><dc:creator>Yusnan Badruzzaman</dc:creator><dc:creator>Revi Alvin Razaqi</dc:creator><dc:subject>three-phase distribution transformer</dc:subject><dc:subject>transformer condition monitoring</dc:subject><dc:subject>Internet of Things</dc:subject><dc:subject>SCADA</dc:subject><dc:subject>Arduino Mega 2560</dc:subject><dc:subject>voltage sensing</dc:subject><dc:subject>current sensing</dc:subject><dc:subject>transformer loading</dc:subject><dc:subject>transformer temperature</dc:subject><dc:subject>Ethernet shield</dc:subject><dc:subject>power distribution networks</dc:subject><dc:description xml:lang="en">The three-phase distribution transfomer, equipment for stepping down the voltage from medium (20/11,5 kV) to low voltage network (400/231 V) with a constant power, is a type of the PT. PLN (Persero) assets which has a direct relationship with customers. The condition and the performance of transformer are affecting on how the continuity of the electricity distributed. Hence, the monitoring process of three-phase distribution transfomer condition and performance should be done. Some elements which have to be monitored such as voltage (ZMPT101B sensor), current (ACS712 30 A sensor), power, and transfomer load. Those elements could be included as an electrical indicator.And then the transfomer’s temperature (DS18B20 sensor) and the oil transfomer level (HC SR04 sensor) could be included as a mechanical indicator. All of the sensors are processed and programmed with Arduino Mega 2560 which has been connected directly into an additional modul called Ethernet shield and router. The results then emitted by WiFi into SCADA to be shown. The results shown by SCADA is the information whether transformer need to be maintened or not</dc:description><dc:publisher>LPPM Institut Teknologi Telkom Purwokerto</dc:publisher><dc:date>2023-05-08</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.20895/infotel.v15i2.937</dc:identifier><dc:identifier>10.20895/infotel.v15i2.937</dc:identifier><dc:source>JURNAL INFOTEL; Vol 15 No 2 (2023); 89-97</dc:source><dc:source>2085-3688</dc:source><dc:source>2460-0997</dc:source><dc:language>en</dc:language><dc:relation>https://ejournal.st3telkom.ac.id/index.php/infotel/article/download/937/446</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>