Abstrak
Electrical impedance tomography (EIT) supports recent advancements in gastric monitoring for telehealth applications. The challenge in providing low-cost EIT is ensuring a stable current injection over diverse tissue conductivities within the abdominal cavity. Three current source circuits based on Howland's current source are investigated to be applied in a low-cost portable bioimpedance analyzer (p-BIA). Those are: a) triple amplifier Howland current source (TAHCS), b) mirrored Howland current source (MHCS), and c) composite mirrored Howland current source (CMHCS). Evaluation has been conducted based on signal-to-noise ratio (SNR), broadness of the frequency range, and output impedance over frequency value and stability. Due to its high SNR value (82.56 to 102.1 dB), broad (500 Hz to 500 kHz) operating frequency, and consistent output impedance over operating frequency (10 to 25 kΩ), CMHCS is a good option in realizing p-BIA in gastric monitoring based EIT.
Jaringan kolaborasi para penulis
10 penulis ·
21 tautan kepenulisan bersama
· 5 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Universitas Pasundan Universitas Gadjah Mada Universitas Pendidikan Putra Indonesia Cianjur Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210188896, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Performance Comparison of Three Modified Howland Current Source Circuits in Low-Cost Bioimpedance Analyzer for Bio-Phantom Signal Acquisition</dc:title><dc:creator>Eka Firmansyah</dc:creator><dc:creator>Ridwan Wicaksono</dc:creator><dc:subject>Howland current source</dc:subject><dc:subject>electrical impedance tomography</dc:subject><dc:subject>telemedicine</dc:subject><dc:subject>output impedance</dc:subject><dc:subject>signal-to-noise ratio</dc:subject><dc:description xml:lang="en">Electrical impedance tomography (EIT) supports recent advancements in gastric monitoring for telehealth applications. The challenge in providing low-cost EIT is ensuring a stable current injection over diverse tissue conductivities within the abdominal cavity. Three current source circuits based on Howland's current source are investigated to be applied in a low-cost portable bioimpedance analyzer (p-BIA). Those are: a) triple amplifier Howland current source (TAHCS), b) mirrored Howland current source (MHCS), and c) composite mirrored Howland current source (CMHCS). Evaluation has been conducted based on signal-to-noise ratio (SNR), broadness of the frequency range, and output impedance over frequency value and stability. Due to its high SNR value (82.56 to 102.1 dB), broad (500 Hz to 500 kHz) operating frequency, and consistent output impedance over operating frequency (10 to 25 kΩ), CMHCS is a good option in realizing p-BIA in gastric monitoring based EIT.</dc:description><dc:publisher>LPPM Institut Teknologi Telkom Purwokerto</dc:publisher><dc:date>2025-07-08</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.20895/infotel.v17i2.1218</dc:identifier><dc:identifier>10.20895/infotel.v17i2.1218</dc:identifier><dc:source>JURNAL INFOTEL; Vol 17 No 2 (2025); 418-439</dc:source><dc:source>2085-3688</dc:source><dc:source>2460-0997</dc:source><dc:language>en</dc:language><dc:relation>https://ejournal.ittelkom-pwt.ac.id/index.php/infotel/article/download/1218/559</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat ID karya OpenAlex (record dari sumber OpenAlex)
1 sitasi
Crossref
Terindeks
lewat DOI
1 sitasi
Jumlah menurut tiap indeks pada 19 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Firmansyah, E., & Wicaksono, R. (2025). Performance Comparison of Three Modified Howland Current Source Circuits in Low-Cost Bioimpedance Analyzer for Bio-Phantom Signal Acquisition. JURNAL INFOTEL, 17(2), 418–439. https://doi.org/10.20895/infotel.v17i2.1218
Salin
IEEE
E. Firmansyah and R. Wicaksono, “Performance Comparison of Three Modified Howland Current Source Circuits in Low-Cost Bioimpedance Analyzer for Bio-Phantom Signal Acquisition,” JURNAL INFOTEL, vol. 17, no. 2, pp. 418–439, 2025, doi: 10.20895/infotel.v17i2.1218.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.