Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Optimization of Electric Multiple Unit Headway

JURNAL INFOTEL · Vol. 17 No. 1 (2025) · hlm. 179–190

DOI
10.20895/infotel.v17i1.1230
ISSN
2085-3688, 2460-0997
Terbit
2025-05-15
Penerbit
LPPM Institut Teknologi Telkom Purwokerto
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The needs of the people of JABODETABEK, Indonesia, for fast, safe, and comfortable means of transportation, such as electric rail trains, are increasing. In 2023, the narrowing of the headway on the East Bekasi-Cikarang station route will cause frequent tripping of the traction substation. This is due to the increasing frequency of multiple electric unit trips and the lack of power capacity at the traction substations to supply electrical power. In addition to that, there is a voltage drop in the overhead power network because the distance between the traction substations is too long. The fastest headway is 3 minutes from the original 13 minutes. This research aims to optimize the power capacity of the traction substation in the LAA 1.10 Cikarang area. The method is load flow analysis using ETAP 19.0.1 software. Results of the design for adding the Tambun Insertion substation and the Telaga Murni Insertion substation. On a 3-minute headway, the average voltage drop increased by 22.5% on the East Bekasi - Cibitung route from 1,222 VDC to 1,497 VDC. Meanwhile, the Cibitung-Cikarang route, originally 1,282 VDC, became 1,494 VDC, or an increase of 16.5%.

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Nasional University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210188896, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Optimization of Electric Multiple Unit Headway</dc:title><dc:creator>Ruliyanta Ruliyanta</dc:creator><dc:creator>Fahmi Idris</dc:creator><dc:creator>Adhyartha Keraf</dc:creator><dc:subject>electric multiple units</dc:subject><dc:subject>traction substations</dc:subject><dc:subject>power capacity</dc:subject><dc:subject>voltage drop</dc:subject><dc:subject>power flow analysis</dc:subject><dc:description xml:lang="en">The needs of the people of JABODETABEK, Indonesia, for fast, safe, and comfortable means of transportation, such as electric rail trains, are increasing. In 2023, the narrowing of the headway on the East Bekasi-Cikarang station route will cause frequent tripping of the traction substation. This is due to the increasing frequency of multiple electric unit trips and the lack of power capacity at the traction substations to supply electrical power. In addition to that, there is a voltage drop in the overhead power network because the distance between the traction substations is too long. The fastest headway is 3 minutes from the original 13 minutes. This research aims to optimize the power capacity of the traction substation in the LAA 1.10 Cikarang area. The method is load flow analysis using ETAP 19.0.1 software. Results of the design for adding the Tambun Insertion substation and the Telaga Murni Insertion substation. On a 3-minute headway, the average voltage drop increased by 22.5% on the East Bekasi - Cibitung route from 1,222 VDC to 1,497 VDC. Meanwhile, the Cibitung-Cikarang route, originally 1,282 VDC, became 1,494 VDC, or an increase of 16.5%.</dc:description><dc:publisher>LPPM Institut Teknologi Telkom Purwokerto</dc:publisher><dc:date>2025-05-15</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.20895/infotel.v17i1.1230</dc:identifier><dc:identifier>10.20895/infotel.v17i1.1230</dc:identifier><dc:source>JURNAL INFOTEL; Vol 17 No 1 (2025); 179-190</dc:source><dc:source>2085-3688</dc:source><dc:source>2460-0997</dc:source><dc:language>en</dc:language><dc:relation>https://ejournal.ittelkom-pwt.ac.id/index.php/infotel/article/download/1230/542</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>