Abstrak

A Bedside monitor is the equipment used to monitor patient condition through some parameters that need sustainable monitoring so that the patient condition is always monitored. This research is monitored by 5 parameters namely heart signal, heart rate, temperature, respiration and SPO2. This research applies quasi experimental design. The free variable is an ECG phantom or human, and the dependent variable is a bedside monitor. The research instruments are a calibration equipment of ECG signal, temperature, and respiration. The result of the heart signal lead 2 is not different from the standard and the result of the heart rate lead has uncertainty (probability) 0 for Lead 2; which is still under the tolerance number (0.5). The results of the temperature measurement of 5 samples with 5 measurements show that there are 3 samples which have standard deviation and 0 (zero) uncertainty, whereas 2 samples have 0.76 (higher than 0.5) uncertainty. This condition is influenced by the patient movements, so the sensor attached on the patient-body does not fit with the standard installation. The respiration measurement results have an accuracy of 98%, while the SPO2 results have a standard deviation and uncertainty below 5% after being compared with the standard calculations. Here are the details: standard deviation 0.894427; 0.547723; 0.44; Probability 0.4; 0.244949; 0.2 and 0.2. Overall, it can be concluded that The Design of Bedside Monitor Based on Microcontroller is feasible and the measurement result of heart signal Lead 2, heart rate, temperature, respiration, SPO2 can be presented on a PC.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 4 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Poltekkes Kemenkes Surabaya
  • Rumah Sakit Umum Pusat Dr. Sardjito
  • Universitas Airlangga
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Suhartono Taat PutraUniversitas Airlangga1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210188896, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Design Of Bedside Monitor Based On Microcontroller</dc:title><dc:creator>Bambang Guruh Irianto</dc:creator><dc:creator>Agus Susilo Wibowo</dc:creator><dc:creator>Dwi Herry Andayani</dc:creator><dc:subject>microcontroller-based monitoring</dc:subject><dc:subject>ECG monitoring</dc:subject><dc:subject>heart rate measurement</dc:subject><dc:subject>body temperature measurement</dc:subject><dc:subject>respiratory monitoring</dc:subject><dc:subject>pulse oximetry</dc:subject><dc:subject>SpO2</dc:subject><dc:subject>measurement accuracy</dc:subject><dc:description xml:lang="en">A Bedside monitor is the equipment used to monitor patient condition through some parameters that need sustainable monitoring so that the patient condition is always monitored. This research is monitored by 5 parameters namely heart signal, heart rate, temperature, respiration and SPO2. This research applies quasi experimental design. The free variable is an ECG phantom or human, and the dependent variable is a bedside monitor. The research instruments are a calibration equipment of ECG signal, temperature, and respiration. The result of the heart signal lead 2 is not different from the standard and the result of the heart rate lead has uncertainty (probability) 0 for Lead 2; which is still under the tolerance number (0.5). The results of the temperature measurement of 5 samples with 5 measurements show that there are 3 samples which have standard deviation and 0 (zero) uncertainty, whereas 2 samples have 0.76 (higher than 0.5) uncertainty. This condition is influenced by the patient movements, so the sensor attached on the patient-body does not fit with the standard installation. The respiration measurement results have an accuracy of 98%, while the SPO2 results have a standard deviation and uncertainty below 5% after being compared with the standard calculations. Here are the details: standard deviation 0.894427; 0.547723; 0.44; Probability 0.4; 0.244949; 0.2 and 0.2. Overall, it can be concluded that The Design of Bedside Monitor Based on Microcontroller is feasible and the measurement result of heart signal Lead 2, heart rate, temperature, respiration, SPO2 can be presented on a PC.</dc:description><dc:publisher>LPPM Institut Teknologi Telkom Purwokerto</dc:publisher><dc:date>2019-11-30</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.20895/infotel.v11i4.443</dc:identifier><dc:identifier>10.20895/infotel.v11i4.443</dc:identifier><dc:source>JURNAL INFOTEL; Vol 11 No 4 (2019)</dc:source><dc:source>2085-3688</dc:source><dc:source>2460-0997</dc:source><dc:language>en</dc:language><dc:relation>https://ejournal.st3telkom.ac.id/index.php/infotel/article/download/443/272</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>