Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Design and Experimental Evaluation of a UV-C Disinfection Robotic Manipulator Integrated with a Mobile Robot Platform

JURNAL INFOTEL · Vol. 18 No. 3 (2026) · hlm. 388–410

DOI
10.20895/infotel.v18i3.11124
ISSN
2085-3688, 2460-0997
Terbit
2026-08-31
Penerbit
LPPM Institut Teknologi Telkom Purwokerto
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0/

Abstrak

This paper presents the design and experimental evaluation of the an ultraviolet C (UV-C) disinfection robotic manipulator integrated with a mobile robot platform for contactless indoor disinfection. The system supports hospital infection-control procedures by enabling remote positioning of UV-C lamps toward shadow-prone surfaces while reducing operator exposure. The manipulator has three degrees of freedom (3-DoF) and is implemented as an articulated arm driven by four linear actuators and equipped with two UV-C lamps near the end-effector. The evaluation covered actuator driver voltage, travel time, joint-angle range, vertical reach, and forward kinematics-based workspace estimation. The driver output voltage decreased from 12.6 V at idle to 12.0–12.2 V during operation, indicating stable power delivery under load. The actuator travel time ranged from 14.70 s to 16.32 s. The measured joint-angle ranges were 20◦–62◦, 18◦–62◦, and 38◦–67◦ for Joints 1–3, respectively, with an end-effector height of 129.5–224 cm. The forward kinematics model estimated a horizontal reach of−76.3–137.9 cm and a vertical workspace of 134.5–220.5 cm. These results indicate that the manipulator can carry and orient dual UV-C lamps across multiple configurations for indoor disinfection. Future work will include UV dose mapping, irradiation uniformity analysis, and microbiological validation.

Kata kunci

Jaringan kolaborasi para penulis

8 penulis · 18 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Muhammadiyah University of Yogyakarta
  • Universitas Ahmad Dahlan
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Akrom AkromUniversitas Ahmad Dahlan1
Titiek HidayatiMuhammadiyah University of Yogyakarta1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210188896, pertama di-harvest 19 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Design and Experimental Evaluation of a UV-C Disinfection Robotic Manipulator Integrated with a Mobile Robot Platform</dc:title><dc:creator>Rama Okta Wiyagi</dc:creator><dc:creator>Muhamad Yusvin Mustar</dc:creator><dc:creator>Tony Khristanto Hariadi</dc:creator><dc:creator>Maria Ulfa</dc:creator><dc:creator>Arya Adiningrat</dc:creator><dc:creator>Bintang Surya Tryatmojo</dc:creator><dc:subject>UV-C disinfection</dc:subject><dc:subject>robot manipulators</dc:subject><dc:subject>mobile robot platform</dc:subject><dc:subject>hospital infection control</dc:subject><dc:subject>articulated arm</dc:subject><dc:subject>linear actuator</dc:subject><dc:subject>UV-C lamps</dc:subject><dc:subject>forward kinematics</dc:subject><dc:description xml:lang="en">This paper presents the design and experimental evaluation of the an ultraviolet C (UV-C) disinfection robotic manipulator integrated with a mobile robot platform for contactless indoor disinfection. The system supports hospital infection-control procedures by enabling remote positioning of UV-C lamps toward shadow-prone surfaces while reducing operator exposure. The manipulator has three degrees of freedom (3-DoF) and is implemented as an articulated arm driven by four linear actuators and equipped with two UV-C lamps near the end-effector. The evaluation covered actuator driver voltage, travel time, joint-angle range, vertical reach, and forward kinematics-based workspace estimation. The driver output voltage decreased from 12.6 V at idle to 12.0–12.2 V during operation, indicating stable power delivery under load. The actuator travel time ranged from 14.70 s to 16.32 s. The measured joint-angle ranges were 20◦–62◦, 18◦–62◦, and 38◦–67◦ for Joints 1–3, respectively, with an end-effector height of 129.5–224 cm. The forward kinematics model estimated a horizontal reach of−76.3–137.9 cm and a vertical workspace of 134.5–220.5 cm. These results indicate that the manipulator can carry and orient dual UV-C lamps across multiple configurations for indoor disinfection. Future work will include UV dose mapping, irradiation uniformity analysis, and microbiological validation.</dc:description><dc:publisher>LPPM Institut Teknologi Telkom Purwokerto</dc:publisher><dc:date>2026-08-31</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.20895/infotel.v18i3.11124</dc:identifier><dc:identifier>10.20895/infotel.v18i3.11124</dc:identifier><dc:source>JURNAL INFOTEL; Vol 18 No 3 (2026); 388-410</dc:source><dc:source>2085-3688</dc:source><dc:source>2460-0997</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>