Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Direct Current Load Prediction Using Machine Learning Model for Enhanced Telecommunications Reliability

JURNAL INFOTEL · Vol. 18 No. 2 (2026) · hlm. 257–272

DOI
10.20895/infotel.v18i2.1485
ISSN
2085-3688, 2460-0997
Terbit
2026-08-03
Penerbit
LPPM Institut Teknologi Telkom Purwokerto
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

The reliable operation of Base Transceiver Stations (BTS) is essential for ensuring consistent mobile network performance, particularly in regions where internet usage continues to rise. One of the critical parameters in BTS power management is the DC Load, which reflects the current consumption of BTS equipment and is crucial for determining battery requirements during power outages. However, most BTS sites in Indonesia lack Power Monitoring Systems (PMS), resulting in the absence of real-time DC Load data needed for effective energy planning. This study proposes a regression-based machine learning approach to estimate DC Load by utilizing operational parameters such as BTS power consumption, traffic, connected users, and PRB utilization. Both single-feature and multi-feature regression models were developed using Linear Regression, Decision Tree Regressor, Random Forest Regressor, and XGBoost. The results show that BTS Power (kWh) has the highest correlation with DC Load, making it an effective single predictor for baseline modeling. The single-feature Linear Regression model performs best under high-load conditions, whereas the Random Forest Regressor provides superior accuracy under low-load scenarios, achieving an R² of up to 0.995. An adaptive hybrid model combining both algorithms was implemented to optimize prediction performance across varying load ranges. The proposed method was applied to approximately 3,500 BTS sites without PMS in Central Java, enabling more accurate battery sizing and improving operational reliability. Overall, this research demonstrates that machine learning can serve as a practical and efficient tool for DC Load prediction, supporting energy optimization and infrastructure planning in telecommunication networks.

Jaringan kolaborasi para penulis

16 penulis · 33 tautan kepenulisan bersama · 10 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Jenderal Soedirman University
  • Institut Teknologi Telkom Purwokerto
  • Universitas Gadjah Mada
  • King Abdulaziz University
  • Institut Teknologi Sepuluh Nopember
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ari FadliJenderal Soedirman University5
Adhistya Erna PermanasariUniversitas Gadjah Mada1
Waleed AliKing Abdulaziz University1
Andreas Sahir AryantoJenderal Soedirman University1
Yogi RamadhaniJenderal Soedirman University1
Eko MurdiyantoroJenderal Soedirman University1
Muntaqo Alfin AmanafInstitut Teknologi Telkom Purwokerto1
Eka Setia NugrahaInstitut Teknologi Telkom Purwokerto1
Muhammad Syaiful AliimJenderal Soedirman University1
Acep TaryanaInstitut Teknologi Sepuluh Nopember1
Azis Wisnu Widhi NugrahaJenderal Soedirman University1
Arief Wisnu WardhanaJenderal Soedirman University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210188896, pertama di-harvest 19 Nov 2026, terakhir terlihat 19 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Direct Current Load Prediction Using Machine Learning Model for Enhanced Telecommunications Reliability</dc:title><dc:creator>Daffa Afif Nasrudin</dc:creator><dc:creator>Mulki Indana Zulfa</dc:creator><dc:creator>Norma Amalia</dc:creator><dc:creator>Wicaksono Widiatmoko</dc:creator><dc:description xml:lang="en">The reliable operation of Base Transceiver Stations (BTS) is essential for ensuring consistent mobile network performance, particularly in regions where internet usage continues to rise. One of the critical parameters in BTS power management is the DC Load, which reflects the current consumption of BTS equipment and is crucial for determining battery requirements during power outages. However, most BTS sites in Indonesia lack Power Monitoring Systems (PMS), resulting in the absence of real-time DC Load data needed for effective energy planning. This study proposes a regression-based machine learning approach to estimate DC Load by utilizing operational parameters such as BTS power consumption, traffic, connected users, and PRB utilization. Both single-feature and multi-feature regression models were developed using Linear Regression, Decision Tree Regressor, Random Forest Regressor, and XGBoost. The results show that BTS Power (kWh) has the highest correlation with DC Load, making it an effective single predictor for baseline modeling. The single-feature Linear Regression model performs best under high-load conditions, whereas the Random Forest Regressor provides superior accuracy under low-load scenarios, achieving an R² of up to 0.995. An adaptive hybrid model combining both algorithms was implemented to optimize prediction performance across varying load ranges. The proposed method was applied to approximately 3,500 BTS sites without PMS in Central Java, enabling more accurate battery sizing and improving operational reliability. Overall, this research demonstrates that machine learning can serve as a practical and efficient tool for DC Load prediction, supporting energy optimization and infrastructure planning in telecommunication networks.</dc:description><dc:publisher>LPPM Institut Teknologi Telkom Purwokerto</dc:publisher><dc:date>2026-08-03</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.20895/infotel.v18i2.1485</dc:identifier><dc:identifier>10.20895/infotel.v18i2.1485</dc:identifier><dc:source>JURNAL INFOTEL; Vol 18 No 2 (2026); 257-272</dc:source><dc:source>2085-3688</dc:source><dc:source>2460-0997</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>