Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

In-Situ hygrothermal evaluation of ventilation block as adaptive climate buffer in contemporary tropical house of Indonesia

ARTEKS Jurnal Teknik Arsitektur · Vol. 11 No. 2 (2026) · hlm. 377–392

DOI
10.30822/arteks.v11i2.4170
ISSN
2541-0598, 2541-1217
Terbit
2026-06-01
Penerbit
Universitas Katolik Widya Mandira
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0/

Abstrak

Within tropical urban environments, passive cooling strategies have become increasingly essential in mitigating the escalating energy consumption associated with achieving indoor thermal comfort. Among the passive cooling approaches suitable for the hot-humid tropical climate of Indonesia, comfort-oriented ventilation through the application of ventilation blocks demonstrates considerable potential. Nevertheless, the actual thermal behavior and environmental performance of ventilation blocks as an integrated system within tropical residential architecture remain insufficiently investigated. This study examines the hygrothermal performance of ventilation blocks as adaptive climatic buffers in urban housing environments. Four contemporary residential buildings in Surabaya were selected as case studies, representing the hot-humid climatic characteristics of Indonesia. Field measurements were conducted over a continuous 30-day monitoring period using temperature and humidity sensors. The instruments were positioned at a height of 1.5 m above the floor surface. Buffered hygrothermal conditions were successfully achieved within the indoor spaces of the contemporary houses. This environmental condition produced the lowest average indoor temperature (28.1°C), the longest thermal comfort duration (16 hours), and the smallest temperature and humidity fluctuations (2.7°C and 11%). Configurations incorporating high opening ratios and hygroscopic materials demonstrated greater effectiveness in moderating moisture levels. Meanwhile, configurations characterized by moderate opening ratios and material thicknesses generated the most optimal spatial heat propagation performance and the longest cooling duration.

Kata kunci

Jaringan kolaborasi para penulis

19 penulis · 43 tautan kepenulisan bersama · 10 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Brawijaya
  • Universitas Merdeka Malang
  • Ministerio de Transportes, Movilidad y Agenda Urbana
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Antariksa SudiknoUniversity of Brawijaya2
Amin Setyo LeksnonoAfiliasi tidak diketahui1
Antariksa AntariksaUniversity of Brawijaya1
Erlina Laksmiani WahjutamiUniversitas Merdeka Malang1
Zulkifli H. AchmadUniversity of Brawijaya1
Ambrosius Alfonso Korasony Sevili GobangUniversity of Brawijaya1
Ayu Nur Izzati HilmyUniversity of Brawijaya1
Rika Nur FitrianiUniversity of Brawijaya1
Alya Nafisa FidelistaUniversity of Brawijaya1
Jono WardoyoUniversity of Brawijaya1
Respati WikantiyosoUniversitas Merdeka Malang1
Aditya Galih SulaksonoUniversitas Merdeka Malang1
Nurul AiniUniversitas Merdeka Malang1
Sari MawaddahniUniversitas Merdeka Malang1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210214341, pertama di-harvest 20 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">In-Situ hygrothermal evaluation of ventilation block as adaptive climate buffer in contemporary tropical house of Indonesia</dc:title><dc:creator>Agung Murti Nugroho</dc:creator><dc:creator>Muhammad Nur Fajri Alfata</dc:creator><dc:creator>Andika Citraningrum</dc:creator><dc:creator>Wasiska Iyati</dc:creator><dc:creator>Fernanda Ayuning Putri</dc:creator><dc:subject>passive cooling</dc:subject><dc:subject>hygrothermal performance</dc:subject><dc:subject>indoor thermal comfort</dc:subject><dc:subject>hot and humid climate</dc:subject><dc:subject>hygroscopic materials</dc:subject><dc:subject>opening ratio</dc:subject><dc:subject>moisture buffering</dc:subject><dc:subject>Surabaya</dc:subject><dc:description xml:lang="en">Within tropical urban environments, passive cooling strategies have become increasingly essential in mitigating the escalating energy consumption associated with achieving indoor thermal comfort. Among the passive cooling approaches suitable for the hot-humid tropical climate of Indonesia, comfort-oriented ventilation through the application of ventilation blocks demonstrates considerable potential. Nevertheless, the actual thermal behavior and environmental performance of ventilation blocks as an integrated system within tropical residential architecture remain insufficiently investigated. This study examines the hygrothermal performance of ventilation blocks as adaptive climatic buffers in urban housing environments. Four contemporary residential buildings in Surabaya were selected as case studies, representing the hot-humid climatic characteristics of Indonesia. Field measurements were conducted over a continuous 30-day monitoring period using temperature and humidity sensors. The instruments were positioned at a height of 1.5 m above the floor surface. Buffered hygrothermal conditions were successfully achieved within the indoor spaces of the contemporary houses. This environmental condition produced the lowest average indoor temperature (28.1°C), the longest thermal comfort duration (16 hours), and the smallest temperature and humidity fluctuations (2.7°C and 11%). Configurations incorporating high opening ratios and hygroscopic materials demonstrated greater effectiveness in moderating moisture levels. Meanwhile, configurations characterized by moderate opening ratios and material thicknesses generated the most optimal spatial heat propagation performance and the longest cooling duration.</dc:description><dc:publisher>Universitas Katolik Widya Mandira</dc:publisher><dc:date>2026-06-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.30822/arteks.v11i2.4170</dc:identifier><dc:identifier>10.30822/arteks.v11i2.4170</dc:identifier><dc:source>ARTEKS Jurnal Teknik Arsitektur; Vol 11 No 2 (2026); 377-392</dc:source><dc:source>2541-0598</dc:source><dc:source>2541-1217</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>