Numeric Analysis of Air Distribution in Air-Conditioned Room to Obtain Optimum Energy Effeciency Level

ARTEKS Jurnal Teknik Arsitektur · Vol. 3 No. 1 (2018) · hlm. 45–56

DOI
10.30822/arteks.v3i1.53
ISSN
2541-0598, 2541-1217
Terbit
2018-12-01
Penerbit
Universitas Katolik Widya Mandira
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0/

Abstrak

The demand for household energy in Indonesia is dominated by air conditioning sector. One of the efforts to optimize air conditioner (AC) is to figure out the best air distribution pattern. Nowadays, there are three air distribution types of marketed AC; (1) perfect mixing, (2) displacement, and (3) radiant cooling. This research examines the influence of those types toward energy consuption to ensure indoor thermal comfort. It was conducted by conducting literature review, mathematical calculation, and numerical simulation. Based on SNI 03-6572-2001, the research applied comfort criteria of indoor air temperature of 24oC as setpoint with 28.1oC initial temperature. Energy consumption is estimated based on time required to achieve the setpoint. The fastest cooling time is obtained by displacement in 80 seconds, then perfect mixing in 112 seconds, and the longest is radiant cooling in 460 seconds. Energy calculation establishes three scenarios of heat load represented by air con’s idle time; (a) high load, 30 seconds, (b) moderate load, 60 seconds, and (c) low load, 90 seconds. For 300 hours of operational time per month, displacement consumes (a) 148.4, (b) 116.6, and (c) 96 kWh/month, whilst perfect mixing needs (a) 160.9, (b) 132.8, and (c) 113.1 kWh/month. Lastly, radiant cooling spends (a) 191.5, (b) 180.5, and (c) 170.6 kWh/month.

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Atma Jaya University Yogyakarta
  • University of Pembangunan Nasional Veteran Jawa Timur
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Afif Fajar ZakariyaAtma Jaya University Yogyakarta1
Wendy SunaryaUniversity of Pembangunan Nasional Veteran Jawa Timur1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210214341, pertama di-harvest 20 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Numeric Analysis of Air Distribution in Air-Conditioned Room to Obtain Optimum Energy Effeciency Level</dc:title><dc:creator>Jackobus Ade Prasetya Seputra</dc:creator><dc:subject>air distribution</dc:subject><dc:subject>air conditioning</dc:subject><dc:subject>energy efficiency</dc:subject><dc:subject>displacement ventilation</dc:subject><dc:subject>ideal mixing</dc:subject><dc:subject>radiant cooling</dc:subject><dc:subject>indoor thermal comfort</dc:subject><dc:subject>cooling time</dc:subject><dc:subject>air conditioning energy consumption</dc:subject><dc:subject>heat load</dc:subject><dc:subject>indoor temperature</dc:subject><dc:description xml:lang="en">The demand for household energy in Indonesia is dominated by air conditioning sector. One of the efforts to optimize air conditioner (AC) is to figure out the best air distribution pattern. Nowadays, there are three air distribution types of marketed AC; (1) perfect mixing, (2) displacement, and (3) radiant cooling. This research examines the influence of those types toward energy consuption to ensure indoor thermal comfort. It was conducted by conducting literature review, mathematical calculation, and numerical simulation. Based on SNI 03-6572-2001, the research applied comfort criteria of indoor air temperature of 24oC as setpoint with 28.1oC initial temperature. Energy consumption is estimated based on time required to achieve the setpoint. The fastest cooling time is obtained by displacement in 80 seconds, then perfect mixing in 112 seconds, and the longest is radiant cooling in 460 seconds. Energy calculation establishes three scenarios of heat load represented by air con’s idle time; (a) high load, 30 seconds, (b) moderate load, 60 seconds, and (c) low load, 90 seconds. For 300 hours of operational time per month, displacement consumes (a) 148.4, (b) 116.6, and (c) 96 kWh/month, whilst perfect mixing needs (a) 160.9, (b) 132.8, and (c) 113.1 kWh/month. Lastly, radiant cooling spends (a) 191.5, (b) 180.5, and (c) 170.6 kWh/month.</dc:description><dc:publisher>Universitas Katolik Widya Mandira</dc:publisher><dc:date>2018-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.30822/arteks.v3i1.53</dc:identifier><dc:identifier>10.30822/arteks.v3i1.53</dc:identifier><dc:source>ARTEKS Jurnal Teknik Arsitektur; Vol 3 No 1 (2018); 45-56</dc:source><dc:source>2541-0598</dc:source><dc:source>2541-1217</dc:source><dc:language>en</dc:language><dc:relation>https://journal.unwira.ac.id/index.php/ARTEKS/article/download/53/37</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>