Assessing artificial lighting performance using DIALux in heritage buildings

ARTEKS Jurnal Teknik Arsitektur · Vol. 10 No. 3 (2025) · hlm. 605–624

DOI
10.30822/arteks.v10i3.4442
ISSN
2541-0598, 2541-1217
Terbit
2025-12-01
Penerbit
Universitas Katolik Widya Mandira
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0/

Abstrak

This study aims to turn on artificial outdoor lighting in the State Electricity Company (PLN) Building as a cultural heritage building in the Kayutangan Heritage Area using DIALux Evo simulation with input measurements and observations in the field. This simulation assesses the average lighting level, lighting uniformity, and energy efficiency, with comparisons to national and international standards. The focus of the study includes the average illumination value, lighting uniformity, and glare assessment which will later be developed into the principle of intelligent lighting in preserving cultural heritage buildings. Based on the simulation results, it was found that most areas of the building have lighting levels below SNI standards, especially in outdoor/pedestrian areas (horizontal elements) and facades (vertical elements). The overlay graph shows a significant disparity in light distribution. These results indicate the need for lighting design interventions in pedestrian areas and building facades. The development of lighting design can later be in accordance with considering aspects of surface materials, functionality, energy efficiency, and most importantly, it can support aspects of preserving cultural heritage buildings. This research is expected to be the basis for developing sustainable lighting strategies in cultural heritage buildings, especially in the Kayutangan Area.

Kata kunci

Jaringan kolaborasi para penulis

14 penulis · 39 tautan kepenulisan bersama · 7 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Merdeka Malang
  • University of Brawijaya
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Aditya Galih SulaksonoUniversitas Merdeka Malang4
Pindo TutukoUniversitas Merdeka Malang3
Agung Murti NugrohoUniversity of Brawijaya3
Tonny SuhartonoUniversitas Merdeka Malang2
Erna WinansihUniversitas Merdeka Malang2
Miftahul HudaUniversitas Merdeka Malang2
Sari MawaddahniUniversitas Merdeka Malang2
Amin Setyo LeksnonoAfiliasi tidak diketahui1
Antariksa AntariksaUniversity of Brawijaya1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210214341, pertama di-harvest 20 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Assessing artificial lighting performance using DIALux in heritage buildings</dc:title><dc:creator>Sirly Intan Sayekti</dc:creator><dc:creator>Respati Wikantiyoso</dc:creator><dc:creator>Nurhamdoko Bonifacius</dc:creator><dc:creator>Erlina Laksmiani Wahjutami</dc:creator><dc:creator>Nurul Aini</dc:creator><dc:subject>historic buildings</dc:subject><dc:subject>DIALux simulation</dc:subject><dc:subject>illuminance uniformity</dc:subject><dc:subject>glare assessment</dc:subject><dc:subject>average illuminance</dc:subject><dc:subject>energy efficiency</dc:subject><dc:subject>sustainable lighting design</dc:subject><dc:subject>facade lighting</dc:subject><dc:description xml:lang="en">This study aims to turn on artificial outdoor lighting in the State Electricity Company (PLN) Building as a cultural heritage building in the Kayutangan Heritage Area using DIALux Evo simulation with input measurements and observations in the field. This simulation assesses the average lighting level, lighting uniformity, and energy efficiency, with comparisons to national and international standards. The focus of the study includes the average illumination value, lighting uniformity, and glare assessment which will later be developed into the principle of intelligent lighting in preserving cultural heritage buildings. Based on the simulation results, it was found that most areas of the building have lighting levels below SNI standards, especially in outdoor/pedestrian areas (horizontal elements) and facades (vertical elements). The overlay graph shows a significant disparity in light distribution. These results indicate the need for lighting design interventions in pedestrian areas and building facades. The development of lighting design can later be in accordance with considering aspects of surface materials, functionality, energy efficiency, and most importantly, it can support aspects of preserving cultural heritage buildings. This research is expected to be the basis for developing sustainable lighting strategies in cultural heritage buildings, especially in the Kayutangan Area.</dc:description><dc:publisher>Universitas Katolik Widya Mandira</dc:publisher><dc:date>2025-12-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.30822/arteks.v10i3.4442</dc:identifier><dc:identifier>10.30822/arteks.v10i3.4442</dc:identifier><dc:source>ARTEKS Jurnal Teknik Arsitektur; Vol 10 No 3 (2025); 605-624</dc:source><dc:source>2541-0598</dc:source><dc:source>2541-1217</dc:source><dc:language>en</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>