The Reconfiguration of Network at 20 kV Distribution System Nagan Raya Substation with the Addition of the Krueng Isep Hydroelectric Power Plant

Jurnal Nasional Teknik Elektro · Vol. 10 No. 2 (2021)

DOI
10.25077/jnte.v10n2.888.2021
ISSN
2302-2949, 2407-7267
Terbit
2021-07-01
Penerbit
Andalas University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-sa/4.0/

Abstrak

Switching substations are usually supplied from one express feeder which can cause a low level of reliability due to disruption or outage on the express feeder. Also, the lack of power supply at the ends of the network causes voltage drops. One way to solve this problem is to reconfigure the network. In this study, testing was carried out on a distribution system in the Nagan Raya Regency, namely the distribution system of PT. PLN (Persero) ULP Jeuram originally had a radial system. Furthermore, the distribution system was reconfigured with the Krueng Isep hydroelectric power plant which was included in the PLN ULP Jeuram grid so that the system that was originally radial became a loop configuration. The method used in analyzing the network reconfiguration process is to use the ETAP 12.6 application. As a result, after reconfiguring the network the voltage increased from 19.2 kV to 20.7 kV, the highest increase was at the Beutong Substation which reached 1.5 kV and decreased power losses in the network with a total of 188.2 kW and 263.1 kVAR. Furthermore, before the network reconfiguration, ULP Jeuram SAIFI value was 22.25 times/customers and SAIDI values 1337.74 minutes/ customers. However, after reconfiguring the network, ULP Jeuram SAIFI value fell to 15.39 times/customers and SAIDI to 945.6 minutes/customers, resulting in an increase in system reliability by 70.69%. Keyword: Reconfiguration of network, distribution system, hydroelectric power plant, SAIDI, SAIFI

Kata kunci

Jaringan kolaborasi para penulis

17 penulis · 39 tautan kepenulisan bersama · 21 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Malikussaleh University
  • Tanjungpura University
  • Universitas Iskandar Muda
  • Politeknik Negeri Lhokseumawe
  • Universitas Jambi
  • Hasanuddin University
  • Institut Teknologi PLN
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Lusyndatul MassuroHasanuddin University1
Riza AdriatTanjungpura University1
Andi IhwanTanjungpura University1
Yuris SutantoTanjungpura University1
Ansar AnsarAfiliasi tidak diketahui1
Revis AsraUniversitas Jambi1
Wenny NurefliaUniversitas Jambi1
Arnawan HasibuanMalikussaleh University1
Muhammad DaudMalikussaleh University1
Abubakar DabetMalikussaleh University1
Fajar Syahbakti LukmanAfiliasi tidak diketahui1
Gandi SupriadiInstitut Teknologi PLN1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210175326, pertama di-harvest 20 Nov 2026, terakhir terlihat 20 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">The Reconfiguration of Network at 20 kV Distribution System Nagan Raya Substation with the Addition of the Krueng Isep Hydroelectric Power Plant</dc:title><dc:creator>Ediwan Ediwan</dc:creator><dc:creator>Muliadi Muliadi</dc:creator><dc:creator>Mahalla Mahalla</dc:creator><dc:creator>Nazaruddin Nazaruddin</dc:creator><dc:creator>Andi Mulkan</dc:creator><dc:subject>distribution network reconfiguration</dc:subject><dc:subject>20 kV distribution network</dc:subject><dc:subject>loop configuration</dc:subject><dc:subject>radial distribution systems</dc:subject><dc:subject>power losses</dc:subject><dc:subject>voltage drop</dc:subject><dc:subject>SAIFI</dc:subject><dc:subject>SAIDI</dc:subject><dc:subject>power supply reliability</dc:subject><dc:description xml:lang="en">Switching substations are usually supplied from one express feeder which can cause a low level of reliability due to disruption or outage on the express feeder. Also, the lack of power supply at the ends of the network causes voltage drops. One way to solve this problem is to reconfigure the network. In this study, testing was carried out on a distribution system in the Nagan Raya Regency, namely the distribution system of PT. PLN (Persero) ULP Jeuram originally had a radial system. Furthermore, the distribution system was reconfigured with the Krueng Isep hydroelectric power plant which was included in the PLN ULP Jeuram grid so that the system that was originally radial became a loop configuration. The method used in analyzing the network reconfiguration process is to use the ETAP 12.6 application. As a result, after reconfiguring the network the voltage increased from 19.2 kV to 20.7 kV, the highest increase was at the Beutong Substation which reached 1.5 kV and decreased power losses in the network with a total of 188.2 kW and 263.1 kVAR. Furthermore, before the network reconfiguration, ULP Jeuram SAIFI value was 22.25 times/customers and SAIDI values 1337.74 minutes/ customers. However, after reconfiguring the network, ULP Jeuram SAIFI value fell to 15.39 times/customers and SAIDI to 945.6 minutes/customers, resulting in an increase in system reliability by 70.69%. Keyword: Reconfiguration of network, distribution system, hydroelectric power plant, SAIDI, SAIFI</dc:description><dc:publisher>Andalas University</dc:publisher><dc:date>2021-07-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.25077/jnte.v10n2.888.2021</dc:identifier><dc:identifier>10.25077/jnte.v10n2.888.2021</dc:identifier><dc:source>Jurnal Nasional Teknik Elektro; Vol 10 No 2 (2021)</dc:source><dc:source>2302-2949</dc:source><dc:source>2407-7267</dc:source><dc:language>en</dc:language><dc:relation>http://jnte.ft.unand.ac.id/index.php/jnte/article/download/888/423</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>