Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Techno-Economic Simulation of On-grid PV System at a New Grand Mosque in Bukittinggi using HOMER

Jurnal Nasional Teknik Elektro · Vol. 11 No. 1 (2022) · hlm. 8–13

DOI
10.25077/jnte.v11n1.985.2022
ISSN
2302-2949, 2407-7267
Terbit
2022-03-29
Penerbit
Andalas University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0/

Abstrak

Mosque is an important building for Muslims worldwide for doing religious activities, such as daily prayers, weekly discourses, and annual celebrations. In many places, mosques are considered appropriate buildings for rooftop solar photovoltaics (PV) installation. This study provides a techno-economic analysis of an on-grid PV system in a great mosque. As a case study, Masjid Tablighiyah Garegeh in Bukittinggi is chosen, which is currently under construction with an expected capacity of up to 1,400 people. This study uses HOMER software as a tool to assess optimum configuration for an on-grid PV system. There are four options that is considered in this study: PV-grid, PV-battery-grid, battery-grid, and grid only system. Optimization results showed that both configurations with PV have promising performance; however, an on-grid PV system without battery system is the most optimum configuration. A 40 kWp PV equipped with a 27 kW converter has the least net present cost with USD 6,902, while the cost of energy when implementing the system is only about USD 4.8 cent per kWh. By implementing the system, 57.2 MWh of electricity will be produced from the PV.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 4 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Andalas University
  • Bandung Institute of Technology
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Umar KhayamBandung Institute of Technology1
Hanalde AndreAndalas University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210175326, pertama di-harvest 20 Nov 2026, terakhir terlihat 20 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Techno-Economic Simulation of On-grid PV System at a New Grand Mosque in Bukittinggi using HOMER</dc:title><dc:creator>Pinto Anugrah</dc:creator><dc:creator>Rizki Wahyu Pratama</dc:creator><dc:subject>grid-connected photovoltaic systems</dc:subject><dc:subject>techno-economic analysis</dc:subject><dc:subject>HOMER optimization</dc:subject><dc:subject>energy costs</dc:subject><dc:subject>net present cost</dc:subject><dc:subject>rooftop solar</dc:subject><dc:subject>Bukittinggi</dc:subject><dc:description xml:lang="en">Mosque is an important building for Muslims worldwide for doing religious activities, such as daily prayers, weekly discourses, and annual celebrations. In many places, mosques are considered appropriate buildings for rooftop solar photovoltaics (PV) installation. This study provides a techno-economic analysis of an on-grid PV system in a great mosque. As a case study, Masjid Tablighiyah Garegeh in Bukittinggi is chosen, which is currently under construction with an expected capacity of up to 1,400 people. This study uses HOMER software as a tool to assess optimum configuration for an on-grid PV system. There are four options that is considered in this study: PV-grid, PV-battery-grid, battery-grid, and grid only system . Optimization results showed that both configurations with PV have promising performance; however, an on-grid PV system without battery system is the most optimum configuration. A 40 kWp PV equipped with a 27 kW converter has the least net present cost with USD 6,902, while the cost of energy when implementing the system is only about USD 4.8 cent per kWh. By implementing the system, 57.2 MWh of electricity will be produced from the PV.</dc:description><dc:publisher>Andalas University</dc:publisher><dc:date>2022-03-29</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.25077/jnte.v11n1.985.2022</dc:identifier><dc:identifier>10.25077/jnte.v11n1.985.2022</dc:identifier><dc:source>Jurnal Nasional Teknik Elektro; Vol 11 No 1 (2022); 8-13</dc:source><dc:source>2302-2949</dc:source><dc:source>2407-7267</dc:source><dc:language>en</dc:language><dc:relation>http://jnte.ft.unand.ac.id/index.php/jnte/article/download/985/444</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>