Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Deep Learning Autoencoder Study on ECG Signals

Jurnal Nasional Teknik Elektro (2023) · hlm. 82–88

DOI
10.25077/jnte.v12n3.1117.2023
ISSN
2302-2949, 2407-7267
Terbit
2023-12-27
Penerbit
Andalas University
Bahasa
en
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0/

Abstrak

Arrhythmia refers to an irregular heart rhythm resulting from disruptions in the heart's electrical activity. To identify arrhythmias, an electrocardiogram (ECG) is commonly employed, as it can record the heart's electrical signals. However, ECGs may encounter interference from sources like electromagnetic waves and electrode motion. Several researchers have investigated the denoising of electrocardiogram signals for arrhythmia detection using deep autoencoder models. Unfortunately, these studies have yielded suboptimal results, indicated by low Signal-to-Noise Ratio (SNR) values and relatively large Root Mean Square Error (RMSE). This study addresses these limitations by proposing the utilization of a Deep LSTM Autoencoder to effectively denoise ECG signals for arrhythmia detection. The model's denoising performance is evaluated based on achieved SNR and RMSE values. The results of the denoising evaluations using the Deep LSTM Autoencoder on the AFDB dataset show SNR and RMSE values of 56.16 and 0.00037, respectively. Meanwhile, for the MITDB dataset, the corresponding values are 65.22 and 0.00018. These findings demonstrate significant improvement compared to previous research. However, it's important to note a limitation in this study—the restricted availability of arrhythmia datasets from MITDB and AFDB. Future researchers are encouraged to explore and acquire a more extensive collection of arrhythmia data to further enhance denoising performance.

Kata kunci

Jaringan kolaborasi para penulis

24 penulis · 58 tautan kepenulisan bersama · 39 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Telkom University
  • University of Technology Malaysia
  • Universiti Teknologi Petronas
  • Ministry of Higher Education and Scientific Research
  • Taibah University
  • Sultan Agung Islamic University
  • University of Baghdad
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Wael M. S. YafoozTaibah University2
Muhammad Bagus QomaruddinSultan Agung Islamic University2
Raey FaldoTelkom University2
Mohd Shahrizal SunarUniversity of Technology Malaysia2
Yvonne Yee Woon KhorUniversity of Technology Malaysia2
Nurul Ashikin binti Abdul KadirUniversity of Technology Malaysia2
Muhammad Najib bin AbdullahAfiliasi tidak diketahui2
Sivakumar BalasubramanianChristian Medical College2
Maryam Hameed AlwanUniversity of Baghdad1
Zainab Abdulrazzaq HameedMinistry of Health1
Faiz Rofi HencyaTelkom University1
Tong Boon TangUniversiti Teknologi Petronas1
Mohd Soperi Mohd ZahidUniversiti Teknologi Petronas1
Muhammad Rafli RamadhanTelkom University1
Rafi UllahHazara University1
Nadia ArianaTelkom University1
Mohd Fadzil HasssanUniversiti Teknologi Petronas1
Bilal Ibrahim BakriAfiliasi tidak diketahui1
Nia Madu MarlianaTelkom University1
Yuan Wen HauUniversity of Technology Malaysia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210175326, pertama di-harvest 20 Nov 2026, terakhir terlihat 20 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">Deep Learning Autoencoder Study on ECG Signals</dc:title><dc:creator>Dandi Mochamad Reza</dc:creator><dc:creator>Satria Mandala</dc:creator><dc:creator>Salim M. Zaki</dc:creator><dc:creator>Eileen Lee Ming Su</dc:creator><dc:subject>ECG denoising</dc:subject><dc:subject>arrhythmia detection</dc:subject><dc:subject>deep autoencoder</dc:subject><dc:subject>LSTM autoencoder</dc:subject><dc:subject>electrocardiogram</dc:subject><dc:subject>signal-to-noise ratio</dc:subject><dc:subject>root mean square error</dc:subject><dc:description xml:lang="en">Arrhythmia refers to an irregular heart rhythm resulting from disruptions in the heart's electrical activity. To identify arrhythmias, an electrocardiogram (ECG) is commonly employed, as it can record the heart's electrical signals. However, ECGs may encounter interference from sources like electromagnetic waves and electrode motion. Several researchers have investigated the denoising of electrocardiogram signals for arrhythmia detection using deep autoencoder models. Unfortunately, these studies have yielded suboptimal results, indicated by low Signal-to-Noise Ratio (SNR) values and relatively large Root Mean Square Error (RMSE). This study addresses these limitations by proposing the utilization of a Deep LSTM Autoencoder to effectively denoise ECG signals for arrhythmia detection. The model's denoising performance is evaluated based on achieved SNR and RMSE values. The results of the denoising evaluations using the Deep LSTM Autoencoder on the AFDB dataset show SNR and RMSE values of 56.16 and 0.00037, respectively. Meanwhile, for the MITDB dataset, the corresponding values are 65.22 and 0.00018. These findings demonstrate significant improvement compared to previous research. However, it's important to note a limitation in this study—the restricted availability of arrhythmia datasets from MITDB and AFDB. Future researchers are encouraged to explore and acquire a more extensive collection of arrhythmia data to further enhance denoising performance.</dc:description><dc:publisher>Andalas University</dc:publisher><dc:date>2023-12-27</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.25077/jnte.v12n3.1117.2023</dc:identifier><dc:identifier>10.25077/jnte.v12n3.1117.2023</dc:identifier><dc:source>Jurnal Nasional Teknik Elektro; (2023); 82-88</dc:source><dc:source>2302-2949</dc:source><dc:source>2407-7267</dc:source><dc:language>en</dc:language><dc:relation>http://jnte.ft.unand.ac.id/index.php/jnte/article/download/1117/507</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>