Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Sistem Peringatan Awal Resiko Preklamsia pada kehamilan menggunakan metoda Certainty Factor dan Android

Jurnal Nasional Teknik Elektro · Vol. 10 No. 1 (2021) · hlm. 45–45

DOI
10.25077/jnte.v10n1.896.2021
ISSN
2302-2949, 2407-7267
Terbit
2021-04-01
Penerbit
Andalas University
Bahasa
id
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0/

Abstrak

The mortality rate for pregnant women due to preeclampsia is still quite high in Indonesia in general and Bengkulu province in particular. There is no effective method to prevent preeclampsia, but early detection can help for proper treatment. Monitoring the condition of pregnancy is very important but the COVID-19 pandemic has prevented pregnant women to go to health facilities. Therefore, a pregnancy condition monitoring system was designed for early detection of preeclampsia using the android-based Certainty Factor method. The system designed consists of a blood pressure measuring device and an expert system. The device uses an MPX5500 pressure sensor, highpass Butterworth filter and an Arduino connected to an android smartphone via Bluetooth. The expert system will diagnose that pregnant women are at risk of preeclampsia or hypertension in pregnancy without the risk of preeclampsia. The blood pressure measuring device works with an average difference to the aneroid sphygmomanometer of 7.05 mmHg with an error of 6.24% at systolic pressure and 10.15 mmHg with an error of 13.13% at diastolic pressure. The result of expert system diagnosis has an accuracy of 91.45%. So it can be said that the designed system can be used Keywords: Preeclampsia, Blood Pressure Device, Certainty Factor MethodAbstrakAngka kematian Ibu hamil (AKI) karena preeklampsia masih cukup tinggi di Indonesia umumnya dan provinsi Bengkulu khususnya. Belum ada metoda yang efektif untuk mencegah terjadinya preeklampsia, tetapi deteksi dini dapat menolong untuk penanganan dan pengobatan yang cepat dan tepat. Monitoring kondisi kehamilan sangat penting, tetapi pandemi COVID-19 menyebabkan ibu hamil tidak dianjurkan untuk ke fasilitas kesehatan. Oleh karena itu dirancang sistem monitoring kondisi kehamilan untuk deteksi dini preeklampsia menggunakan metoda Certainty Factor berbasis Android. Sistem ini terdiri dari alat ukur tekanan darah dan sistem pakar. Alat ukur tensimeter menggunakan sensor tekanan MPX5500, filter high pass butteworth dan mikrokontroller Arduino terhubung ke smartphone android melalui Bluetooth. Sistem pakar akan mendiagnosa ibu hamil beresiko preklampsia atau hipertensi dalam kehamilan tanpa resiko preklamsia. Alat ukur tekanan darah yang dirancang untuk mendukung sistem, bekerja dengan rata-rata selisih terhadap pengukuran tensimeter aneroid sebesar 7,05 mmHg dengan galat 6,24 % pada tekanan sistolik dan 10,15 mmHg dengan galat 13,13 % pada tekanan diastolik. Hasil diagnosa sistem pakar memiliki akurasi sebesar 91,45 %. Sehingga dapat dikatakan bahwa sistem yang dirancang telah dapat digunakan.Kata Kunci: Preklamsia, tensimeter, sistem pakar certainty factor

Kata kunci

Jaringan kolaborasi para penulis

30 penulis · 94 tautan kepenulisan bersama · 26 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Bengkulu
  • Andalas University
  • Sumatera Institute of Technology
  • Politeknik Negeri Padang
  • Universitas PGRI Sumatera Barat
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ruvita FaurinaUniversity of Bengkulu3
Arie VatresiaUniversity of Bengkulu2
Alex SurapatiUniversity of Bengkulu2
Hendy SantosaUniversity of Bengkulu2
Nova ResfitaSumatera Institute of Technology1
Rahmadi KurniaAndalas University1
Vivin PurnamasariUniversity of Bengkulu1
Anisa JelitaUniversity of Bengkulu1
Novalio DarathaUniversity of Bengkulu1
Bagus Imam PrayogaUniversity of Bengkulu1
Mardhatillah SariyantiUniversity of Bengkulu1
Tiara Ayoe AnditaUniversity of Bengkulu1
Noor Diah ErlinawatiUniversity of Bengkulu1
Elvira YunitaUniversity of Bengkulu1
Ahmad Azmi NasutionUniversity of Bengkulu1
Kartika SariUniversity of Bengkulu1
Sylvia Rianissa PutriUniversity of Bengkulu1
Junas HaidiUniversity of Bengkulu1
Firdaus FirdausPoliteknik Negeri Padang1
Rudy FernandezAndalas University1
Heru Dibyo LaksonoAndalas University1
Melda LatifAndalas University1
GaneshaUniversity of Bengkulu1
Yanolanda Suzantry HandayaniUniversity of Bengkulu1
Rahayu Trisetyowati UntariUniversitas PGRI Sumatera Barat1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210175326, pertama di-harvest 20 Nov 2026, terakhir terlihat 20 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="id">Sistem Peringatan Awal Resiko Preklamsia pada kehamilan menggunakan metoda Certainty Factor dan Android</dc:title><dc:creator>Fitrilina Fitrilina</dc:creator><dc:creator>M. Albbi</dc:creator><dc:creator>Indra Agustian</dc:creator><dc:creator>Afriyastuti Herawati</dc:creator><dc:creator>Nikki Aldi Massardi</dc:creator><dc:subject>preeclampsia</dc:subject><dc:subject>early detection</dc:subject><dc:subject>pregnancy monitoring</dc:subject><dc:subject>blood pressure measurement</dc:subject><dc:subject>certainty factor</dc:subject><dc:subject>expert systems</dc:subject><dc:subject>Android application</dc:subject><dc:subject>Bluetooth</dc:subject><dc:subject>Arduino</dc:subject><dc:subject>hypertension in pregnancy</dc:subject><dc:subject>COVID-19 pandemic</dc:subject><dc:subject>maternal mortality</dc:subject><dc:subject>Bengkulu</dc:subject><dc:description xml:lang="id">The mortality rate for pregnant women due to preeclampsia is still quite high in Indonesia in general and Bengkulu province in particular. There is no effective method to prevent preeclampsia, but early detection can help for proper treatment. Monitoring the condition of pregnancy is very important but the COVID-19 pandemic has prevented pregnant women to go to health facilities. Therefore, a pregnancy condition monitoring system was designed for early detection of preeclampsia using the android-based Certainty Factor method. The system designed consists of a blood pressure measuring device and an expert system. The device uses an MPX5500 pressure sensor, highpass Butterworth filter and an Arduino connected to an android smartphone via Bluetooth. The expert system will diagnose that pregnant women are at risk of preeclampsia or hypertension in pregnancy without the risk of preeclampsia. The blood pressure measuring device works with an average difference to the aneroid sphygmomanometer of 7.05 mmHg with an error of 6.24% at systolic pressure and 10.15 mmHg with an error of 13.13% at diastolic pressure. The result of expert system diagnosis has an accuracy of 91.45%. So it can be said that the designed system can be used Keywords : Preeclampsia, Blood Pressure Device, Certainty Factor MethodAbstrakAngka kematian Ibu hamil (AKI) karena preeklampsia masih cukup tinggi di Indonesia umumnya dan provinsi Bengkulu khususnya. Belum ada metoda yang efektif untuk mencegah terjadinya preeklampsia, tetapi deteksi dini dapat menolong untuk penanganan dan pengobatan yang cepat dan tepat. Monitoring kondisi kehamilan sangat penting, tetapi pandemi COVID-19 menyebabkan ibu hamil tidak dianjurkan untuk ke fasilitas kesehatan. Oleh karena itu dirancang sistem monitoring kondisi kehamilan untuk deteksi dini preeklampsia menggunakan metoda Certainty Factor berbasis Android. Sistem ini terdiri dari alat ukur tekanan darah dan sistem pakar. Alat ukur tensimeter menggunakan sensor tekanan MPX5500, filter high pass butteworth dan mikrokontroller Arduino terhubung ke smartphone android melalui Bluetooth. Sistem pakar akan mendiagnosa ibu hamil beresiko preklampsia atau hipertensi dalam kehamilan tanpa resiko preklamsia. Alat ukur tekanan darah yang dirancang untuk mendukung sistem, bekerja dengan rata-rata selisih terhadap pengukuran tensimeter aneroid sebesar 7,05 mmHg dengan galat 6,24 % pada tekanan sistolik dan 10,15 mmHg dengan galat 13,13 % pada tekanan diastolik. Hasil diagnosa sistem pakar memiliki akurasi sebesar 91,45 %. Sehingga dapat dikatakan bahwa sistem yang dirancang telah dapat digunakan.Kata Kunci : Preklamsia, tensimeter, sistem pakar certainty factor</dc:description><dc:publisher>Andalas University</dc:publisher><dc:date>2021-04-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.25077/jnte.v10n1.896.2021</dc:identifier><dc:identifier>10.25077/jnte.v10n1.896.2021</dc:identifier><dc:source>Jurnal Nasional Teknik Elektro; Vol 10 No 1 (2021); 45-45</dc:source><dc:source>2302-2949</dc:source><dc:source>2407-7267</dc:source><dc:language>id</dc:language><dc:relation>http://jnte.ft.unand.ac.id/index.php/jnte/article/download/896/421</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>