Abstrak

This journal discusses about performance analysis of generator excitation system voltage response towards parameters changes. Changes in the parameters of the generator excitation system will affect the response voltage generator excitation system performance, in both time domain and frequency domain performances. The performance analysis of the generator excitation system voltage response in both time domain and frequency domain, conduct with the help of Matlab software. For performance in the time domain is consists of error analysis and transient analysis, while for performance in the frequency domain is consists of the open-loop performance and closed-loop performance. The parameters that to be changed are the amplifier gain constant, amplifier time constant, generator gain constant, and generator time constant. The analysis result shows that the performance of the generator excitation system voltage response in both time domain and frequency domain performances is very sensitive towards the changes in the parameters, especially for the changes of amplifier gain constant, the changes of amplifier time constant, the changes of generator gain constant, and the changes of generator time constant.

Kata kunci

Jaringan kolaborasi para penulis

25 penulis · 51 tautan kepenulisan bersama · 18 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Andalas University
  • University of Bengkulu
  • Universitas Ekasakti
  • Universitas PGRI Sumatera Barat
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Noris Fredi YuliantoAfiliasi tidak diketahui2
Wayu Diafridho AAndalas University2
Aidil DanasUniversitas Ekasakti2
Syafii SyafiiAndalas University1
Muhardika MuhardikaAndalas University1
Syukri YunusAndalas University1
Putri NidyaAndalas University1
MazuesAndalas University1
. .Afiliasi tidak diketahui1
Novizon NovizonAndalas University1
N RiskaAndalas University1
Alrino Rizki RamadhanAndalas University1
Doohan HalimanAndalas University1
Syafi’iAndalas University1
Muhammad Reza PermanaAndalas University1
Firmansyah SaputraAndalas University1
Ismail IsmailAndalas University1
Fitrilina FitrilinaUniversity of Bengkulu1
Melda LatifAndalas University1
Alex SurapatiUniversity of Bengkulu1
GaneshaUniversity of Bengkulu1
Yanolanda Suzantry HandayaniUniversity of Bengkulu1
Rahayu Trisetyowati UntariUniversitas PGRI Sumatera Barat1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210175326, pertama di-harvest 20 Nov 2026, terakhir terlihat 20 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="id">Analisa Performansi Tanggapan Tegangan Sistem Eksitasi Generator Terhadap Perubahan Parameter</dc:title><dc:creator>Heru Dibyo Laksono</dc:creator><dc:creator>Adry Febrianda</dc:creator><dc:subject>generator excitation system</dc:subject><dc:subject>voltage response</dc:subject><dc:subject>parameter sensitivity</dc:subject><dc:subject>transient analysis</dc:subject><dc:subject>closed-loop performance</dc:subject><dc:subject>time-domain analysis</dc:subject><dc:subject>frequency domain analysis</dc:subject><dc:description xml:lang="id">This journal discusses about performance analysis of generator excitation system voltage response towards parameters changes. Changes in the parameters of the generator excitation system will affect the response voltage generator excitation system performance, in both time domain and frequency domain performances. The performance analysis of the generator excitation system voltage response in both time domain and frequency domain, conduct with the help of Matlab software. For performance in the time domain is consists of error analysis and transient analysis, while for performance in the frequency domain is consists of the open-loop performance and closed-loop performance. The parameters that to be changed are the amplifier gain constant, amplifier time constant, generator gain constant, and generator time constant. The analysis result shows that the performance of the generator excitation system voltage response in both time domain and frequency domain performances is very sensitive towards the changes in the parameters, especially for the changes of amplifier gain constant, the changes of amplifier time constant, the changes of generator gain constant, and the changes of generator time constant.</dc:description><dc:publisher>Andalas University</dc:publisher><dc:date>2015-02-24</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.25077/jnte.v4n1.117.2015</dc:identifier><dc:identifier>10.25077/jnte.v4n1.117.2015</dc:identifier><dc:source>Jurnal Nasional Teknik Elektro; Vol 4 No 1 (2015); 63-63</dc:source><dc:source>2302-2949</dc:source><dc:source>2407-7267</dc:source><dc:language>id</dc:language><dc:relation>http://jnte.ft.unand.ac.id/index.php/jnte/article/download/117/136</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>