Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Pengaturan Keseimbangan Pengisian dan Pengosongan Baterai Asam Timbal

Jurnal Nasional Teknik Elektro · Vol. 5 No. 2 (2016) · hlm. 192–192

DOI
10.25077/jnte.v5n2.265.2016
ISSN
2302-2949, 2407-7267
Terbit
2016-05-13
Penerbit
Andalas University
Bahasa
id
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0/

Abstrak

In this paper proposed a system of balance settings for charging and discharging the lead-acid battery using a microcontroller arduino uno 16U2. The calculation of battery capacity using the method of As (Ampere-second). Before this is done, the value of the energy stored in the battery is calculated using the relationship between the battery capacity (SOC) and the open-circuit voltage of the battery. The microcontroller will do the calculations for the system running using any current relationships in the system. Settings are separated between setting the maximum point and minimum point battery battery. Setting the maximum point guard of excess charging batteries. When the battery is full, the current discharge / disposal will flow which prevents the battery charging when it reaches the maximum point. 0153 constant exhaust flow set point A. Setting minimum keep the battery from the void (lack of energy). Load will not get a good supply of energy or battery charger when the battery below the minimum point because the charger is only charging the battery to pass the minimum point. This system uses the point of 11.67% with a minimum capacity of 50 Ah battery. System settings are made has managed to keep the battery from overload conditions and under loading.Keywords: Lead-acid Battery, mosfet, charging and discharging, arduino uno microcontroller Abstrak—Dalam tulisan ini diusulkan suatu sistem pengaturan keseimbangan pengisian (charging) dan pengosongan (discharging) pada baterai asam timbal menggunakan mikrokontroler arduino uno 16U2. Perhitungan kapasitas baterai menggunakan metoda As (Ampere-second). Sebelum sistem ini dijalankan, nilai energi yang tersimpan pada baterai dihitung menggunakan hubungan antara kapasitas baterai (SOC) dan tegangan open circuit baterai. Mikrokontroler akan melakukan perhitungan selama sistem berjalan menggunakan hubungan setiap arus pada sistem. Pengaturan dipisahkan antara pengaturan titik maksimal baterai dan titik minimal baterai. Pengaturan titik maksimal menjaga baterai dari kelebihan pengisian. Saat baterai telah penuh maka arus peluahan/pembuangan akan mengalir yang mencegah baterai mengalami pengisian saat mencapai titik maksimum. Arus pembuangan diset konstan 0.153 A. Pengaturan titik minimum menjaga baterai dari kekosongan (kekurangan energi). Beban tidak akan mendapatkan pasokan energi baik dari charger maupun baterai saat baterai dibawah titik minimumnya karena charger hanya melakukan pengisian pada baterai hingga melewati titik minimumnya. Sistem ini menggunakan titik minimum 11.67% dengan kapasitas baterai 50 Ah. Sistem pengaturan yang dibuat telah berhasil menjaga baterai dari kondisi kelebihan muatan dan kekurangan muatan.Kata Kunci: Baterai asam timbal, mosfet, pengisian dan peluahan, mikrokontroler arduino uno

Kata kunci

Jaringan kolaborasi para penulis

30 penulis · 56 tautan kepenulisan bersama · 14 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Andalas University
  • Badan Pengkajian dan Penerapan Teknologi
  • Universitas Negeri Padang
  • Institut Teknologi Padang
  • Diponegoro University
  • Indian Institute of Technology Indore
  • Sumatera Institute of Technology
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Andi PawawoiAndalas University5
Fajril AkbarAndalas University5
Muhammad Imran HamidAndalas University2
Syafii SyafiiAndalas University2
Krismadinata KrismadinataUniversitas Negeri Padang2
Eka FitriantoAndalas University2
Muhammad Imran HamidAndalas University1
Yudi ArfanAndalas University1
Syafii GhazaliAfiliasi tidak diketahui1
Axel DorizaAndalas University1
Zuriman AnthonyInstitut Teknologi Padang1
Rizka AmaliaDiponegoro University1
Hasmat MalikIndian Institute of Technology Indore1
Dendi Adi SaputraAndalas University1
Igo Cikal MuharramAndalas University1
Asnil AsnilAndalas University1
Muhammad NasirAndalas University1
Mery DianaBadan Pengkajian dan Penerapan Teknologi1
Arief RufiyantoBadan Pengkajian dan Penerapan Teknologi1
Kiki KanandaSumatera Institute of Technology1
Dewi Purnama SariAndalas University1
Novi KurniasihAndalas University1
Melda LatifAndalas University1
Hamdi RezaAndalas University1
Rizka AmaliaAndalas University1
Wahyu Rizki MuslyadiAndalas University1
Elsi Alfionita SyawalAndalas University1
Rahmat HidayatAndalas University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210175326, pertama di-harvest 20 Nov 2026, terakhir terlihat 20 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="id">Pengaturan Keseimbangan Pengisian dan Pengosongan Baterai Asam Timbal</dc:title><dc:creator>Mochammad Rismansyah</dc:creator><dc:creator>Refdinal Nazir</dc:creator><dc:subject>lead-acid batteries</dc:subject><dc:subject>battery charging</dc:subject><dc:subject>battery discharge</dc:subject><dc:subject>state of charge</dc:subject><dc:subject>open-circuit voltage</dc:subject><dc:subject>Arduino Uno</dc:subject><dc:subject>MOSFET</dc:subject><dc:subject>overcharge protection</dc:subject><dc:subject>battery management systems</dc:subject><dc:description xml:lang="id">In this paper proposed a system of balance settings for charging and discharging the lead-acid battery using a microcontroller arduino uno 16U2. The calculation of battery capacity using the method of As (Ampere-second). Before this is done, the value of the energy stored in the battery is calculated using the relationship between the battery capacity (SOC) and the open-circuit voltage of the battery. The microcontroller will do the calculations for the system running using any current relationships in the system. Settings are separated between setting the maximum point and minimum point battery battery. Setting the maximum point guard of excess charging batteries. When the battery is full, the current discharge / disposal will flow which prevents the battery charging when it reaches the maximum point. 0153 constant exhaust flow set point A. Setting minimum keep the battery from the void (lack of energy). Load will not get a good supply of energy or battery charger when the battery below the minimum point because the charger is only charging the battery to pass the minimum point. This system uses the point of 11.67% with a minimum capacity of 50 Ah battery. System settings are made has managed to keep the battery from overload conditions and under loading.Keywords : Lead-acid Battery, mosfet, charging and discharging, arduino uno microcontroller Abstrak—Dalam tulisan ini diusulkan suatu sistem pengaturan keseimbangan pengisian (charging) dan pengosongan (discharging) pada baterai asam timbal menggunakan mikrokontroler arduino uno 16U2. Perhitungan kapasitas baterai menggunakan metoda As (Ampere-second). Sebelum sistem ini dijalankan, nilai energi yang tersimpan pada baterai dihitung menggunakan hubungan antara kapasitas baterai (SOC) dan tegangan open circuit baterai. Mikrokontroler akan melakukan perhitungan selama sistem berjalan menggunakan hubungan setiap arus pada sistem. Pengaturan dipisahkan antara pengaturan titik maksimal baterai dan titik minimal baterai. Pengaturan titik maksimal menjaga baterai dari kelebihan pengisian. Saat baterai telah penuh maka arus peluahan/pembuangan akan mengalir yang mencegah baterai mengalami pengisian saat mencapai titik maksimum. Arus pembuangan diset konstan 0.153 A. Pengaturan titik minimum menjaga baterai dari kekosongan (kekurangan energi). Beban tidak akan mendapatkan pasokan energi baik dari charger maupun baterai saat baterai dibawah titik minimumnya karena charger hanya melakukan pengisian pada baterai hingga melewati titik minimumnya. Sistem ini menggunakan titik minimum 11.67% dengan kapasitas baterai 50 Ah. Sistem pengaturan yang dibuat telah berhasil menjaga baterai dari kondisi kelebihan muatan dan kekurangan muatan.Kata Kunci : Baterai asam timbal, mosfet, pengisian dan peluahan, mikrokontroler arduino uno</dc:description><dc:publisher>Andalas University</dc:publisher><dc:date>2016-05-13</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.25077/jnte.v5n2.265.2016</dc:identifier><dc:identifier>10.25077/jnte.v5n2.265.2016</dc:identifier><dc:source>Jurnal Nasional Teknik Elektro; Vol 5 No 2 (2016); 192-192</dc:source><dc:source>2302-2949</dc:source><dc:source>2407-7267</dc:source><dc:language>id</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>