Abstrak

Installation of distributed generation (DG) is one alternatives to reduce power loss in distribution network. However, the placement of DG with non-optimal capacity and location may affect the voltage profile and voltage stability. This paper aims to find the optimal capacity and location of DG in order to reduce active power losses and improve the voltage profile and the voltage stability index. The simulation is performed by installing a DG on distribution network case studies i.e. IEEE 30 bus system and on the Nila feeder of Metro substation. Two types of DG are used for this simulation, i.e. DG that only produce active power and DG that produce both active and reactive power. Power flow calculations are performed using the forward/backward sweep method and all programming is written using MATLAB software. Simulation results show that the method can obtain the optimal capacity and location of DG. After installation the DGs, power losses, voltage profile and voltage stability index on each bus in Nila feeder have improved.

Kata kunci

Jaringan kolaborasi para penulis

24 penulis · 56 tautan kepenulisan bersama · 10 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Lampung University
  • University of Mataram
  • Institut Teknologi PLN
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
I Made GinarsaUniversity of Mataram5
Ahmad Saudi SamosirLampung University4
Agung Budi MuljonoUniversity of Mataram2
I Made Ari NrarthaUniversity of Mataram2
Sri PurwiyantiLampung University1
Endah KomalasariLampung University1
Dikpride DespaLampung University1
Sony FerbangkaraLampung University1
Sultan SultanUniversity of Mataram1
Ni Made SeniariUniversity of Mataram1
Luthfiyyatun MardiyahLampung University1
Sri Ratna SulistiyantiLampung University1
Alfin Fitrohul HudaLampung University1
Abdul HarisInstitut Teknologi PLN1
Angga Hidson SetiawanLampung University1
Noer SoedjarwantoLampung University1
Jemi AnggaraLampung University1
M. Widi TriyatnoLampung University1
Lukmanul HakimLampung University1
Fandi PrayogaLampung University1
Khairudin KhairudinLampung University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210175326, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="id">Penentuan Kapasitas dan Lokasi Optimal dari Pembangkit Tersebar pada Jaringan Distribusi Penyulang Nila di Gardu Induk Metro</dc:title><dc:creator>Awansah Awansah</dc:creator><dc:creator>Osea Zebua</dc:creator><dc:creator>Herri Gusmedi</dc:creator><dc:subject>distributed generation</dc:subject><dc:subject>optimal DG placement</dc:subject><dc:subject>optimal DG sizing</dc:subject><dc:subject>active power loss minimization</dc:subject><dc:subject>voltage profile improvement</dc:subject><dc:subject>voltage stability index</dc:subject><dc:subject>distribution networks</dc:subject><dc:subject>IEEE 30-bus system</dc:subject><dc:subject>reactive power generation</dc:subject><dc:subject>power loss reduction</dc:subject><dc:subject>voltage stability improvement</dc:subject><dc:subject>power quality improvement</dc:subject><dc:subject>power quality index</dc:subject><dc:description xml:lang="id">Installation of distributed generation (DG) is one alternatives to reduce power loss in distribution network. However, the placement of DG with non-optimal capacity and location may affect the voltage profile and voltage stability. This paper aims to find the optimal capacity and location of DG in order to reduce active power losses and improve the voltage profile and the voltage stability index. The simulation is performed by installing a DG on distribution network case studies i.e. IEEE 30 bus system and on the Nila feeder of Metro substation. Two types of DG are used for this simulation, i.e. DG that only produce active power and DG that produce both active and reactive power. Power flow calculations are performed using the forward/backward sweep method and all programming is written using MATLAB software. Simulation results show that the method can obtain the optimal capacity and location of DG. After installation the DGs, power losses, voltage profile and voltage stability index on each bus in Nila feeder have improved.</dc:description><dc:publisher>Andalas University</dc:publisher><dc:date>2018-11-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.25077/jnte.v7n3.553.2018</dc:identifier><dc:identifier>10.25077/jnte.v7n3.553.2018</dc:identifier><dc:source>Jurnal Nasional Teknik Elektro; Vol 7 No 3 (2018); 153-153</dc:source><dc:source>2302-2949</dc:source><dc:source>2407-7267</dc:source><dc:language>id</dc:language><dc:relation>http://jnte.ft.unand.ac.id/index.php/jnte/article/download/553/359</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>