Abstrak

Signal in the form of voltage are often need to be transmitted when we deal with measurement. However, voltage signal transmission creates many problems. The series resistance that appears between the output of the signal conditioner and the load produces some voltage drop. Even a few millivolts of the voltage drops could significantly alter the percentage error of the measurement. Current signal is the same everywhere in a series loop. So, by converting the signal into a current and then sending the current signal will assures that the load will receive all of the signal we sent. In this paper, a simulation and an implementation of using instrumentation amplifiers and V-I converter for sending a voltage signal has been conducted. The process variable being measured is a differential pressure that is sensed by a pressure sensor. The output voltage signal was then amplified by an instrumentation amplifier and fed to a V-I converter for transmission purpose. The results is an increase in output current when the presssure was increased. It can be concluded that the instrumentation amplifier and V-I converter are the devices that are properly used for a voltage signal transmission.

Kata kunci

Jaringan kolaborasi para penulis

16 penulis · 34 tautan kepenulisan bersama · 10 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Jenderal Soedirman University
  • Universitas Gadjah Mada
  • King Abdulaziz University
  • Institut Teknologi Telkom Purwokerto
  • Institut Teknologi Sepuluh Nopember
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ari FadliJenderal Soedirman University5
Yogi RamadhaniJenderal Soedirman University2
Adhistya Erna PermanasariUniversitas Gadjah Mada1
Waleed AliKing Abdulaziz University1
Andreas Sahir AryantoJenderal Soedirman University1
Eko MurdiyantoroJenderal Soedirman University1
Norma AmaliaInstitut Teknologi Telkom Purwokerto1
Daffa Afif NasrudinAfiliasi tidak diketahui1
Wicaksono WidiatmokoAfiliasi tidak diketahui1
Muhammad Syaiful AliimJenderal Soedirman University1
Acep TaryanaInstitut Teknologi Sepuluh Nopember1
Azis Wisnu Widhi NugrahaJenderal Soedirman University1
Daru Tri NugrohoJenderal Soedirman University1
Priswanto PriswantoJenderal Soedirman University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210175326, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="en">The Use of Instrumentation Amplifiers and Voltage-to-Current Converter In a Process Control : Simulation and Implementation</dc:title><dc:creator>Arief Wisnu Wardhana</dc:creator><dc:creator>Mulki Indana Zulfa</dc:creator><dc:subject>instrumentation amplifier</dc:subject><dc:subject>voltage-to-current converter</dc:subject><dc:subject>signal conditioning</dc:subject><dc:subject>differential pressure measurement</dc:subject><dc:subject>pressure sensors</dc:subject><dc:subject>process control instrumentation</dc:subject><dc:description xml:lang="en">Signal in the form of voltage are often need to be transmitted when we deal with measurement. However, voltage signal transmission creates many problems. The series resistance that appears between the output of the signal conditioner and the load produces some voltage drop. Even a few millivolts of the voltage drops could significantly alter the percentage error of the measurement. Current signal is the same everywhere in a series loop. So, by converting the signal into a current and then sending the current signal will assures that the load will receive all of the signal we sent. In this paper, a simulation and an implementation of using instrumentation amplifiers and V-I converter for sending a voltage signal has been conducted. The process variable being measured is a differential pressure that is sensed by a pressure sensor. The output voltage signal was then amplified by an instrumentation amplifier and fed to a V-I converter for transmission purpose. The results is an increase in output current when the presssure was increased. It can be concluded that the instrumentation amplifier and V-I converter are the devices that are properly used for a voltage signal transmission.</dc:description><dc:publisher>Andalas University</dc:publisher><dc:date>2019-11-10</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.25077/jnte.v8n3.664.2019</dc:identifier><dc:identifier>10.25077/jnte.v8n3.664.2019</dc:identifier><dc:source>Jurnal Nasional Teknik Elektro; Vol 8 No 3 (2019); 104-104</dc:source><dc:source>2302-2949</dc:source><dc:source>2407-7267</dc:source><dc:language>en</dc:language><dc:relation>http://jnte.ft.unand.ac.id/index.php/jnte/article/download/664/382</dc:relation><dc:rights>https://creativecommons.org/licenses/by-sa/4.0/</dc:rights></oai_dc:dc>