Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Analisa Performansi Sistem Kendali Frekuensi Tenaga Listrik Multimesin Dengan Metoda Linear Quadratic Regulator (LQR)

Jurnal Nasional Teknik Elektro · Vol. 3 No. 2 (2014) · hlm. 167–167

DOI
10.25077/jnte.v3n2.82.2014
ISSN
2302-2949, 2407-7267
Terbit
2014-09-01
Penerbit
Andalas University
Bahasa
id
Lisensi
creativecommons.org/licenses/by-nc-sa/4.0/

Abstrak

This journal discusses about the performance analysis of frequency control power system in multi machine with Linear Quadratic Regulator method (LQR). The frequency control power system in multi machine is power subsystem consists of two or more generators are interconnected each other and the most influential subsystem on the performance of power system primarily to the performance toward frequency deviation responses of the power system. The Performance of frequency deviation response power system is one of the important factors that must be considered in the operation of electric power system and the indicator show the performance of the power system during disturbance. Disturbances causes changes in parameter values which lead to frequency control power system in multi machine will be disrupted so it result system no longer able to work normally after disturbance. By using the method of Linear Quadratic Regulator (LQR) is conducted performance analysis of frequency control power system in multi machine. The Performance analysis was conducted on the performance analysis in the time and frequency domain. The result of analysis shows that the performance of frequency deviation response in of multi machine frequency control power system with Linear Quadratic Regulaetor method has better performance.Keywords: Frequency control system, Multi Machine, Linear Quadratic Regulator (LQR)AbstrakJurnal ini membahas tentang analisa performansi sistem kendali frekuensi tenaga listrik multimesin dengan metoda Linear Quadratic Regulator (LQR). Sistem kendali frekuensi tenaga listrik multimesin ini merupakan subsistem tenaga listrik yang terdiri dari dua atau lebih generator yang saling terinterkoneksi dan merupakan subsistem yang paling berpengaruh terhadap performansi sistem tenaga listrik terutama performansi terhadap tanggapan deviasi frekuensi sistem tenaga listrik. Performansi tanggapan deviasi frekuensi sistem tenaga listrik ini merupakan salah satu faktor penting yang harus diperhatikan dalam operasi sistem tenaga listrik dan merupakan salah satu indikator yang menunjukkan performansi sistem tenaga listrik saat terjadi gangguan. Gangguan – gangguan ini menyebabkanperubahan nilai parameter yang mengakibatkansistem kendali frekuensi tenaga listrik multimesin akan terganggu dan berakibat sistem tidak mampu lagi bekerja secara normal setelah mengalami gangguan. Dengan menggunakan metoda Linear Quadratic Regulator (LQR) dilakukan analisa performansi tanggapan deviasi frekuensi dari sistem kendali frekuensi tenaga listrik multimesin. Analisa performansi yang dilakukan meliputi analisa performansi dalam domain waktu dan domain frekuensi. Hasil analisa menunjukkan bahwa performansi tanggapan deviasi frekuensi sistem kendali frekuensi tenaga listrik multimesin dengan metoda metoda Linear Quadratic Regulator (LQR) mempuyai performansi yang lebih baik.Kata kunci: sistem kendali frekuensi, multimesin, Linear Quadratic Regulator (LQR

Kata kunci

Jaringan kolaborasi para penulis

25 penulis · 51 tautan kepenulisan bersama · 18 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Andalas University
  • University of Bengkulu
  • Universitas Ekasakti
  • Universitas PGRI Sumatera Barat
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Noris Fredi YuliantoAfiliasi tidak diketahui2
Wayu Diafridho AAndalas University2
Aidil DanasUniversitas Ekasakti2
Syafii SyafiiAndalas University1
Muhardika MuhardikaAndalas University1
Adry FebriandaAndalas University1
Syukri YunusAndalas University1
Putri NidyaAndalas University1
MazuesAndalas University1
. .Afiliasi tidak diketahui1
Novizon NovizonAndalas University1
N RiskaAndalas University1
Alrino Rizki RamadhanAndalas University1
Doohan HalimanAndalas University1
Syafi’iAndalas University1
Firmansyah SaputraAndalas University1
Ismail IsmailAndalas University1
Fitrilina FitrilinaUniversity of Bengkulu1
Melda LatifAndalas University1
Alex SurapatiUniversity of Bengkulu1
GaneshaUniversity of Bengkulu1
Yanolanda Suzantry HandayaniUniversity of Bengkulu1
Rahayu Trisetyowati UntariUniversitas PGRI Sumatera Barat1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210175326, pertama di-harvest 20 Nov 2026, terakhir terlihat 20 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="id">Analisa Performansi Sistem Kendali Frekuensi Tenaga Listrik Multimesin Dengan Metoda Linear Quadratic Regulator (LQR)</dc:title><dc:creator>Heru Dibyo Laksono</dc:creator><dc:creator>Muhammad Reza Permana</dc:creator><dc:subject>frequency regulation</dc:subject><dc:subject>multi-machine power systems</dc:subject><dc:subject>linear quadratic regulator</dc:subject><dc:subject>power system disturbances</dc:subject><dc:subject>control performance analysis</dc:subject><dc:subject>time and frequency domain analysis</dc:subject><dc:subject>power system stability</dc:subject><dc:subject>power system protection</dc:subject><dc:description xml:lang="id">This journal discusses about the performance analysis of frequency control power system in multi machine with Linear Quadratic Regulator method (LQR). The frequency control power system in multi machine is power subsystem consists of two or more generators are interconnected each other and the most influential subsystem on the performance of power system primarily to the performance toward frequency deviation responses of the power system. The Performance of frequency deviation response power system is one of the important factors that must be considered in the operation of electric power system and the indicator show the performance of the power system during disturbance. Disturbances causes changes in parameter values which lead to frequency control power system in multi machine will be disrupted so it result system no longer able to work normally after disturbance. By using the method of Linear Quadratic Regulator (LQR) is conducted performance analysis of frequency control power system in multi machine. The Performance analysis was conducted on the performance analysis in the time and frequency domain. The result of analysis shows that the performance of frequency deviation response in of multi machine frequency control power system with Linear Quadratic Regulaetor method has better performance.Keywords: Frequency control system, Multi Machine , Linear Quadratic Regulator (LQR)AbstrakJurnal ini membahas tentang analisa performansi sistem kendali frekuensi tenaga listrik multimesin dengan metoda Linear Quadratic Regulator (LQR). Sistem kendali frekuensi tenaga listrik multimesin ini merupakan subsistem tenaga listrik yang terdiri dari dua atau lebih generator yang saling terinterkoneksi dan merupakan subsistem yang paling berpengaruh terhadap performansi sistem tenaga listrik terutama performansi terhadap tanggapan deviasi frekuensi sistem tenaga listrik. Performansi tanggapan deviasi frekuensi sistem tenaga listrik ini merupakan salah satu faktor penting yang harus diperhatikan dalam operasi sistem tenaga listrik dan merupakan salah satu indikator yang menunjukkan performansi sistem tenaga listrik saat terjadi gangguan. Gangguan – gangguan ini menyebabkanperubahan nilai parameter yang mengakibatkansistem kendali frekuensi tenaga listrik multimesin akan terganggu dan berakibat sistem tidak mampu lagi bekerja secara normal setelah mengalami gangguan. Dengan menggunakan metoda Linear Quadratic Regulator (LQR) dilakukan analisa performansi tanggapan deviasi frekuensi dari sistem kendali frekuensi tenaga listrik multimesin. Analisa performansi yang dilakukan meliputi analisa performansi dalam domain waktu dan domain frekuensi. Hasil analisa menunjukkan bahwa performansi tanggapan deviasi frekuensi sistem kendali frekuensi tenaga listrik multimesin dengan metoda metoda Linear Quadratic Regulator (LQR) mempuyai performansi yang lebih baik.Kata kunci : sistem kendali frekuensi, multimesin, Linear Quadratic Regulator (LQR</dc:description><dc:publisher>Andalas University</dc:publisher><dc:date>2014-09-01</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.25077/jnte.v3n2.82.2014</dc:identifier><dc:identifier>10.25077/jnte.v3n2.82.2014</dc:identifier><dc:source>Jurnal Nasional Teknik Elektro; Vol 3 No 2 (2014); 167-167</dc:source><dc:source>2302-2949</dc:source><dc:source>2407-7267</dc:source><dc:language>id</dc:language><dc:relation>http://jnte.ft.unand.ac.id/index.php/jnte/article/download/82/77</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>