Abstrak

At 20 kV radial distribution systems supplied by the substation in a considerable distance from the load centre, will cause occurred its voltage drop significantly. The integration of distributed generation on the distribution networks will be one of the solutions to reduce the drop voltage. This paper proposes a way to analyze the effect of integration multiple distributed generation (DG) in radial distribution networks to the voltage drop. This analysis uses the injection current method of the load and the DG on each bus. The analysis results showed that the penetration of 5 units of DG on the distribution network will reduce its voltage drops significantly, especially on the adjacent bus with DG.

Kata kunci

Jaringan kolaborasi para penulis

30 penulis · 56 tautan kepenulisan bersama · 14 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Andalas University
  • Badan Pengkajian dan Penerapan Teknologi
  • Universitas Negeri Padang
  • Institut Teknologi Padang
  • Diponegoro University
  • Indian Institute of Technology Indore
  • Sumatera Institute of Technology
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Andi PawawoiAndalas University5
Fajril AkbarAndalas University5
Muhammad Imran HamidAndalas University2
Syafii SyafiiAndalas University2
Krismadinata KrismadinataUniversitas Negeri Padang2
Muhammad Imran HamidAndalas University1
Yudi ArfanAndalas University1
Syafii GhazaliAfiliasi tidak diketahui1
Axel DorizaAndalas University1
Zuriman AnthonyInstitut Teknologi Padang1
Rizka AmaliaDiponegoro University1
Hasmat MalikIndian Institute of Technology Indore1
Dendi Adi SaputraAndalas University1
Igo Cikal MuharramAndalas University1
Asnil AsnilAndalas University1
Muhammad NasirAndalas University1
Mery DianaBadan Pengkajian dan Penerapan Teknologi1
Arief RufiyantoBadan Pengkajian dan Penerapan Teknologi1
Kiki KanandaSumatera Institute of Technology1
Dewi Purnama SariAndalas University1
Novi KurniasihAndalas University1
Melda LatifAndalas University1
Hamdi RezaAndalas University1
Rizka AmaliaAndalas University1
Wahyu Rizki MuslyadiAndalas University1
Mochammad RismansyahAndalas University1
Elsi Alfionita SyawalAndalas University1
Rahmat HidayatAndalas University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210175326, pertama di-harvest 20 Nov 2026, terakhir terlihat 20 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="id">Efek Pengintegrasian Pembangkit Listrik Tersebar pada Sistem Distribusi Radial terhadap Perbaikan Tegangan</dc:title><dc:creator>Eka Fitrianto</dc:creator><dc:creator>Refdinal Nazir</dc:creator><dc:subject>distributed generation</dc:subject><dc:subject>radial distribution systems</dc:subject><dc:subject>voltage drop</dc:subject><dc:subject>voltage improvement</dc:subject><dc:subject>distributed generation integration</dc:subject><dc:subject>DG penetration level</dc:subject><dc:subject>20 kV distribution network</dc:subject><dc:description xml:lang="id">At 20 kV radial distribution systems supplied by the substation in a considerable distance from the load centre, will cause occurred its voltage drop significantly. The integration of distributed generation on the distribution networks will be one of the solutions to reduce the drop voltage. This paper proposes a way to analyze the effect of integration multiple distributed generation (DG) in radial distribution networks to the voltage drop. This analysis uses the injection current method of the load and the DG on each bus. The analysis results showed that the penetration of 5 units of DG on the distribution network will reduce its voltage drops significantly, especially on the adjacent bus with DG.</dc:description><dc:publisher>Andalas University</dc:publisher><dc:date>2016-01-28</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://doi.org/10.20449/jnte.v5i1.157</dc:identifier><dc:identifier>10.20449/jnte.v5i1.157</dc:identifier><dc:source>Jurnal Nasional Teknik Elektro; Vol 5 No 1 (2016); 1-6</dc:source><dc:source>2302-2949</dc:source><dc:source>2407-7267</dc:source><dc:language>id</dc:language><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>