Air Conditioning (AC) is used every day in buildings. AC dominates energy consumption of a building. This research aims to reduce AC energy consumption by controlling the room temperature between 22,8°C to 27,1°C. The air conditioning machine is controlled by a working time predictive system that based on number of people in the room. The predictive control is success in maintained room temperature in comfortable temperature i.e. between 24,6° C to 27,1° C.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 5 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Politeknik Negeri Indramayu
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Arief Wahyu RamadhanPoliteknik Negeri Indramayu2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OpenAlex API (jurnal SINTA, ADR 0048) https://openalex.org/S4210175326, pertama di-harvest 22 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/"><dc:title xml:lang="id">Pemanfaatan Sensor Inframerah untuk Input Kontrol Prediktif Temperatur pada Mesin Air Conditioning (AC) secara Wireless</dc:title><dc:creator>Rofan Aziz</dc:creator><dc:creator>Agung Kamaluddin</dc:creator><dc:creator>Karsid Karsid</dc:creator><dc:subject>air conditioning</dc:subject><dc:subject>predictive control</dc:subject><dc:subject>infrared sensors</dc:subject><dc:subject>room occupancy detection</dc:subject><dc:subject>wireless control</dc:subject><dc:subject>Arduino</dc:subject><dc:subject>energy consumption reduction</dc:subject><dc:subject>indoor temperature control</dc:subject><dc:subject>building energy efficiency</dc:subject><dc:description xml:lang="id">Air Conditioning (AC) is used every day in buildings. AC dominates energy consumption of a building. This research aims to reduce AC energy consumption by controlling the room temperature between 22,8°C to 27,1°C. The air conditioning machine is controlled by a working time predictive system that based on number of people in the room. The predictive control is success in maintained room temperature in comfortable temperature i.e. between 24,6° C to 27,1° C.</dc:description><dc:publisher>Andalas University</dc:publisher><dc:date>2018-11-08</dc:date><dc:type>info:eu-repo/semantics/article</dc:type><dc:format>application/pdf</dc:format><dc:identifier>https://doi.org/10.25077/jnte.v7n3.581.2018</dc:identifier><dc:identifier>10.25077/jnte.v7n3.581.2018</dc:identifier><dc:source>Jurnal Nasional Teknik Elektro; Vol 7 No 3 (2018); 209-209</dc:source><dc:source>2302-2949</dc:source><dc:source>2407-7267</dc:source><dc:language>id</dc:language><dc:relation>http://jnte.ft.unand.ac.id/index.php/jnte/article/download/581/367</dc:relation><dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights></oai_dc:dc>